scholarly journals Computation of Full-Coverage Film-Cooled Airfoil Temperatures by Two Methods and Comparison With High Heat Flux Data

Author(s):  
H. J. Gladden ◽  
F. C. Yeh ◽  
P. J. Austin

Two methods were used to calculate the heat flux to full-coverage film cooled airfoils and, subsequently, the airfoil wall temperatures. The calculated wall temperatures were compared to measured temperatures obtained in the Hot Section Facility operating at real engine conditions. Gas temperatures and pressures up to 1900 K and 18 atm with a Reynolds number up to 1.9 million were investigated. Heat flux was calculated by the convective heat transfer coefficient adiabatic wall method and by the superposition method which incorporates the film injection effects in the heat transfer coefficient. The results of the comparison indicate the first method can predict the experimental data reasonably well. However, superposition overpredicted the heat flux to the airfoil without a significant modification of the turbulent Prandtl number. The results of this research suggests that additional research is required to model the physics of full-coverage film cooling where there is significant temperature/density differences between the gas and coolant.

2015 ◽  
Vol 138 (3) ◽  
Author(s):  
Peter Schreivogel ◽  
Michael Pfitzner

A new approach for steady-state heat transfer measurements is proposed. Temperature distributions are measured at the surface and a defined depth inside the wall to provide boundary conditions for a three-dimensional heat flux calculation. The practical application of the technique is demonstrated by employing a superposition method to measure heat transfer and film cooling effectiveness downstream of two different 0.75D deep narrow trench geometries and cylindrical holes. Compared to the cylindrical holes, both trench geometries lead to an augmentation of the heat transfer coefficient supposedly caused by the highly turbulent attached cooling film emanating from the trenches. Areas of high heat transfer are visible, where recirculation bubbles or large amounts of coolant are expected. Increasing the density ratio from 1.33 to 1.60 led to a slight reduction of the heat transfer coefficient and an increased cooling effectiveness. Both trenches provide a net heat flux reduction (NHFR) superior to that of cylindrical holes, especially at the highest momentum flux ratios.


Author(s):  
Emily J. Boyd ◽  
John W. McClintic ◽  
Kyle F. Chavez ◽  
David G. Bogard

Knowing the heat transfer coefficient augmentation is imperative to predicting film cooling performance on turbine components. In the past, heat transfer coefficient augmentation was generally measured at unit density ratio to keep measurements simple and uncertainty low. Some researchers have measured heat transfer coefficient augmentation while taking density ratio effects into account, but none have made direct temperature measurements of the wall and adiabatic wall to calculate hf/h0 at higher density ratios. This work presents results from measuring the heat transfer coefficient augmentation downstream of shaped holes with a 7° forward and lateral expansion at DR = 1.0, 1.2, and 1.5 on a flat plate using a constant heat flux surface. The results showed that the heat transfer coefficient augmentation was low while the jets were attached to the surface and increased when the jets started to separate. At DR = 1.0, hf/h0 was higher for a given blowing ratio than at DR = 1.2 and DR = 1.5. However, when velocity ratios are matched, better correspondence was found at the different density ratios. Surface contours of hf/h0 showed that the heat transfer was initially increased along the centerline of the jet, but was reduced along the centerline at distances farther downstream. The decrease along the centerline may be due to counter-rotating vortices sweeping warm air next to the heat flux plate toward the center of the jet, where they sweep upward and thicken the thermal boundary layer. This warming of the core of the coolant jet over the heated surface was confirmed with thermal field measurements.


2016 ◽  
Vol 139 (1) ◽  
Author(s):  
Emily J. Boyd ◽  
John W. McClintic ◽  
Kyle F. Chavez ◽  
David G. Bogard

Knowing the heat transfer coefficient augmentation is imperative to predicting film cooling performance on turbine components. In the past, heat transfer coefficient augmentation was generally measured at unit density ratio to keep measurements simple and uncertainty low. Some researchers have measured heat transfer coefficient augmentation while taking density ratio effects into account, but none have made direct temperature measurements of the wall and adiabatic wall to calculate hf/h0 at higher density ratios. This work presents results from measuring the heat transfer coefficient augmentation downstream of shaped holes with a 7 deg forward and lateral expansion at DR = 1.0, 1.2, and 1.5 on a flat plate using a constant heat flux surface. The results showed that the heat transfer coefficient augmentation was low while the jets were attached to the surface and increased when the jets started to separate. At DR = 1.0, hf/h0 was higher for a given blowing ratio than at DR = 1.2 and DR = 1.5. However, when velocity ratios are matched, better correspondence was found at the different density ratios. Surface contours of hf/h0 showed that the heat transfer was initially increased along the centerline of the jet, but was reduced along the centerline at distances farther downstream. The decrease along the centerline may be due to counter-rotating vortices sweeping warm air next to the heat flux plate toward the center of the jet, where they sweep upward and thicken the thermal boundary layer. This warming of the core of the coolant jet over the heated surface was confirmed with thermal field measurements.


Author(s):  
Peter Schreivogel ◽  
Michael Pfitzner

A new approach for steady state heat transfer measurements is proposed. Temperature distributions are measured at the surface and a defined depth inside the wall to provide boundary conditions for a three-dimensional heat flux calculation. The practical application of the technique is demonstrated by employing a superposition method to measure heat transfer and film cooling effectiveness downstream of two different 0.75D deep narrow trench geometries and cylindrical holes. Compared to the cylindrical holes, both trench geometries lead to an augmentation of the heat transfer coefficient supposedly caused by the highly turbulent attached cooling film emanating from the trenches. Areas of high heat transfer are visible, where recirculation bubbles or large amounts of coolant are expected. Increasing the density ratio from 1.33 to 1.60 led to a slight reduction of the heat transfer coefficient and an increased cooling effectiveness. Both trenches provide a net heat flux reduction superior to that of cylindrical holes, especially at the highest momentum flux ratios.


Author(s):  
O. Popp ◽  
D. E. Smith ◽  
J. V. Bubb ◽  
H. C. Grabowski ◽  
T. E. Diller ◽  
...  

This paper reports on an investigation of the heat transfer on the suction side of a transonic film cooled turbine rotor blade in a linear cascade. Heat transfer coefficient and film effectiveness are first determined for steady conditions. The unsteady effects of a passing shock on the heat transfer are then investigated. The film cooling pattern used is a showerhead design with three rows on the suction side, one row at the stagnation point and two rows on the pressure side. The experiments were performed at engine representative temperature and pressure ratios using air as coolant. Heat transfer measurements are obtained using a Heat Flux Microsensor, and surface temperature is monitored with a surface thermocouple. Static pressure is monitored with a Kulite pressure transducer. The shock emerging from the trailing edge of the NGV and impinging on the rotor blades is modeled by passing a shock wave along the leading edges of the cascade blades. The steady-state heat transfer coefficient is 8% higher with film cooling than without film cooling. Shock heating of the freestream flow is determined to be the major contribution to the unsteady variation of heat flux, leading to an increase of about 30°C to 35°C in recovery temperature and adiabatic wall temperature.


2008 ◽  
Vol 130 (3) ◽  
Author(s):  
James D. Heidmann ◽  
Srinath Ekkad

A novel turbine film-cooling hole shape has been conceived and designed at NASA Glenn Research Center. This “antivortex” design is unique in that it requires only easily machinable round holes, unlike shaped film-cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film-cooling holes. This vorticity typically entrains hot freestream gas and is associated with jet separation from the turbine blade surface. The antivortex film-cooling hole concept has been modeled computationally for a single row of 30 deg angled holes on a flat surface using the 3D Navier–Stokes solver GLENN-HT. A blowing ratio of 1.0 and density ratios of 1.05 and 2.0 are studied. Both film effectiveness and heat transfer coefficient values are computed and compared to standard round hole cases for the same blowing rates. A net heat flux reduction is also determined using both the film effectiveness and heat transfer coefficient values to ascertain the overall effectiveness of the concept. An improvement in film effectiveness of about 0.2 and in net heat flux reduction of about 0.2 is demonstrated for the antivortex concept compared to the standard round hole for both blowing ratios. Detailed flow visualization shows that as expected, the design counteracts the detrimental vorticity of the round hole flow, allowing it to remain attached to the surface.


Author(s):  
Akira Matsui ◽  
Kazuhisa Yuki ◽  
Hidetoshi Hashizume

Detailed heat transfer characteristics of particle-sintered porous media and metal foams are evaluated to specify the important structural parameters suitable for high heat removal. The porous media used in this experiment are particle-sintered porous media made of bronze and SUS316L, and metal foams made of copper and nickel. Cooling water flows into the porous medium opposite to heat flux input loaded by a plasma arcjet. The result indicates that the bronze-particle porous medium of 100μm in pore size shows the highest performance and achieves heat transfer coefficient of 0.035MW/m2K at inlet heat flux 4.6MW/m2. Compared with the heat transfer performance of copper fiber-sintered porous media, the bronze particlesintered ones give lower heat transfer coefficient. However, the stable cooling conditions that the heat transfer coefficient does not depend on the flow velocity, were confirmed even at heat flux of 4.6MW/m2 in case of the bronze particle-sintered media, while not in the case of the copper-fiber sintered media. This signifies the possibility that the bronze-particle sintered media enable much higher heat flux removal of over 10MW/m2, which could be caused by higher permeability of the particle-sintered pore structures. Porous media with high permeability provide high performance of vapor evacuation, which leads to more stable heat removal even under extremely high heat flux. On the other hand, the heat transfer coefficient of the metal foams becomes lower because of the lower capillary and fin effects caused by too high porosity and low effective thermal conductivity. It is concluded that the pore structure having high performance of vapor evacuation as well as the high capillary and high fin effects is appropriate for extremely high heat flux removal of over 10MW/m2.


2011 ◽  
Vol 133 (6) ◽  
Author(s):  
Avijit Bhunia ◽  
C. L. Chen

The necessity for an efficient thermal management system covering large areas is growing rapidly with the push toward more electric systems. A significant amount of research over the past 2 decades has conclusively proved the suitability of jet, droplet, or spray impingement for high heat flux cooling. However, all these research consider small heat source areas, typically about a few cm2. Can a large array of impingement pattern, covering a much wider area, achieve similar heat flux levels? This article presents liquid microjet array impingement cooling of a heat source that is about two orders of magnitude larger than studied in the previous works. Experiments are carried out with 441 jets of de-ionized water and a dielectric liquid HFE7200, each 200 μm diameter. The jets impinge on a 189 cm2 area surface, in free surface and confined jet configurations. The average heat transfer coefficient values of the present experiment are compared with correlations from the literature. While some correlations show excellent agreement, others deviate significantly. The ensuing discussion suggests that the post-impingement liquid dynamics, particularly the collision between the liquid fronts on the surface created from surrounding jets, is the most important criterion dictating the average heat transfer coefficient. Thus, similar thermal performance can be achieved, irrespective of the length scale, as long as the flow dynamics are similar. These results prove the scalability of the liquid microjet array impingement technique for cooling a few cm2 area to a few hundred cm2 area.


Author(s):  
S. Baldauf ◽  
M. Scheurlen ◽  
A. Schulz ◽  
S. Wittig

Heat transfer coefficients and the resulting heat flux reduction due to film cooling on a flat plate downstream a row of cylindrical holes are investigated. Highly resolved two dimensional heat transfer coefficient distributions were measured by means of infrared thermography and carefully corrected for local internal testplate conduction and radiation effects [1]. These locally acquired data are processed to lateral average heat transfer coefficients for a quantitative assessment. A wide range variation of the flow parameters blowing rate and density ratio as well as the geometrical parameters streamwise ejection angle and hole spacing is examined. The effects of these dominating parameters on the heat transfer augmentation from film cooling are discussed and interpreted with the help of highly resolved surface results of effectiveness and heat transfer coefficients presented earlier [2]. A new method of evaluating the heat flux reduction from film cooling is presented. From a combination of the lateral average of both the adiabatic effectiveness and the heat transfer coefficient, the lateral average heat flux reduction is processed according to the new method. The discussion of the total effect of film cooling by means of the heat flux reduction reveals important characteristics and constraints of discrete hole ejection. The complete heat transfer data of all measurements are used as basis for a new correlation of lateral average heat transfer coefficients. This correlation combines the effects of all the dominating parameters. It yields a prediction of the heat transfer coefficient from the ejection position to far downstream, including effects of extreme blowing angles and hole spacing. The new correlation has a modular structure to allow for future inclusion of additional parameters. Together with the correlation of the adiabatic effectiveness it provides an immediate determination of the streamwise heat flux reduction distribution of cylindrical hole film cooling configurations.


Sign in / Sign up

Export Citation Format

Share Document