The Effect of the Thickness and Angle of the Inlet and Outlet Guide Vane on the Performance of Axial-Flow Pump

Author(s):  
Sang-Won Kim ◽  
Youn-Jea Kim

An axial-flow pump has a relatively high discharge flow rate and specific speed at a relatively low head and it consists of an inlet guide vane, impeller, and outlet guide vane. The interaction of the flow through the inlet guide vane, impeller, and outlet guide vane of the axial-flow pump has a significant effect on its performance. Of those components, the guide vanes especially can improve the head and efficiency of the pump by transforming the kinetic energy of the rotating flow, which has a tangential velocity component, into pressure energy. Accordingly, the geometric configurations of the guide vanes such as blade thickness and angle are crucial design factors for determining the performance of the axial-flow pump. As the reliability of Computational Fluid Dynamics (CFD) has been elevated together with the advance in computer technology, numerical analysis using CFD has recently become an alternative to empirical experiment due to its high reliability to measure the flow field. Thus, in this study, 1,200mm axial-flow pump having an inlet guide vane and impeller with 4 blades and an outlet guide vane with 6 blades was numerically investigated. Numerical study was conducted using the commercial CFD code, ANSYS CFX ver. 16.1, in order to elucidate the effect of the thickness and angle of the guide vanes on the performance of 1,200mm axial-flow pump. The stage condition, which averages the fluxes between interfaces and is accordingly appropriate for the evaluation of pump performance, was adopted as the interface condition between the guide vanes and the impeller. The rotational periodicity condition was used in order to enable a simplified geometry to be used since the guide vanes feature multiple identical regions. The shear stress transport (SST) k-ω model, predicting the turbulence within the flow in good agreement, was also employed in the CFD calculation. With regard to the numerical simulation results, the characteristics of the pressure distribution were discussed in detail. The pump performance, which will determine how well an axial-flow pump will work in terms of its efficiency and head, was also discussed in detail, leading to the conclusion on the optimal blade thickness and angle for the improvement of the performance. In addition, the total pressure loss coefficient was considered in order to investigate the loss within the flow paths depending on the thickness and angle variations. The results presented in this study may give guidelines to the numerical analysis of the axial-flow pump and the investigation of the performance for further optimal design of the axial-flow pump.

Author(s):  
Wei-Min Feng ◽  
Jing-Ye Pan ◽  
Zhi-Wei Guo ◽  
Qian Cheng

The effects of variable-inlet guide vanes on the performance of an axial flow pump considering tip clearance are investigated. The performance and the main flow field of the whole passage with five different angles of inlet guide vanes ( −10°, −5°, 0°, 5°, 10°) and with two tip clearance sizes (1‰ and 2‰) are presented. The results show that when the angle of inlet guide vane increases from negative values to positive values, the pump head reduces for two tip clearance sizes. This is mainly caused by the change of inlet velocity triangle of blade. Moreover, as tip clearance size increases from 1‰ to 2‰, both the pump head and efficiency decrease because of increasing of the strength of tip clearance leakage vortex and reverse flow.


Author(s):  
Youn-Sung Kim ◽  
Hyeon-Seok Shim ◽  
Kwang-Yong Kim

This study aims to evaluate effects of blade pitch and inlet guide vane (IGV) angle on the performance characteristics of a submersible axial-flow pump. According to the results of the previous study, the efficiency at the design and over-load conditions were significantly affected by the angle of IGV due to change in the incidence angle. To investigate the interactional effects of IGV and blade angle are analyzed using three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model. The hexahedral grids are used in the computational domain and a grid-dependency test is performed to obtain an optimal number of the grids. In this study, combinations of three different blade angles and two different IGV angles are tested. Adjusting angle of IGV increases the total pressure of the pump with a blade pitch increase, which can increase the efficiency of the pump in operating range.


1990 ◽  
Vol 112 (2) ◽  
pp. 294-297 ◽  
Author(s):  
J. H. Horlock

An actuator disk analysis is given of the flow through a guide vane and rotor combination. It is shown that changes in total pressure across the rotor are in general related to circumferential variations in guide vane outlet angle. In particular known variations in inlet total pressure may be eliminated by suitable circumferential changes in guide vane stagger.


2012 ◽  
Vol 15 (6) ◽  
pp. 58-63 ◽  
Author(s):  
Hyun-Chang Park ◽  
Sung Kim ◽  
Joon-Yong Yoon ◽  
Young-Seok Choi

Author(s):  
Youn-Sung Kim ◽  
Hyeon-Seok Shim ◽  
Kwang-Yong Kim

This study investigates the effects of inlet guide vane (IGV) and blade pitch angles on the steady and unsteady performance of a submersible axial-flow pump. To analyze the interaction between the IGVs and the rotor blades, both steady and unsteady three-dimensional Reynolds-averaged Navier-Stokes equations were used with shear stress transport turbulence closure. Hexahedral meshes were used in the computational domain. The numerical results for performance curves showed good agreement with experimental data. The results showed that the steady and unsteady performance characteristics were dependent on both the IGV and blade pitch angles. Adjusting these angles affected the total pressure rise and thus caused variation in the efficiency in overload conditions. But adjusting these angles affected the unsteady pressure fluctuations in partial-load conditions. Detailed flow analyses were performed to find the root-cause of these phenomena.


2016 ◽  
Vol 99 ◽  
pp. 1146-1152 ◽  
Author(s):  
Zhongdong Qian ◽  
Fan Wang ◽  
Zhiwei Guo ◽  
Jie Lu

2013 ◽  
Vol 52 (3) ◽  
pp. 032011
Author(s):  
W J Wang ◽  
Q H Liang ◽  
Y Wang ◽  
Y Yang ◽  
G Yin ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Fan Yang ◽  
Hao-ru Zhao ◽  
Chao Liu

In order to investigate the influence of adjustable outlet guide vane on the hydraulic performance of axial-flow pump at part loads, the axial-flow pump with 7 different outlet guide vane adjustable angles was simulated based on the RNG k-ε turbulent model and Reynolds time-averaged equations. The Vector graphs of airfoil flow were analyzed in the different operating conditions for different adjustable angles of guide vane. BP-ANN prediction model was established about the effect of adjustable outlet guide vane on the hydraulic performance of axial-flow pump based on the numerical results. The effectiveness of prediction model was verified by theoretical analysis and numerical simulation. The results show that, with the adjustable angle of guide vane increasing along clockwise, the high efficiency area moves to the large flow rate direction; otherwise, that moves to the small flow rate direction. The internal flow field of guide vane is improved by adjusting angle, and the flow separation of tail and guide vane inlet ledge are decreased or eliminated, so that the hydraulic efficiency of pumping system will be improved. The prediction accuracy of BP-ANN model is 1%, which can meet the requirement of practical engineering.


2016 ◽  
Vol 8 (6) ◽  
pp. 168781401665158 ◽  
Author(s):  
Weimin Feng ◽  
Qian Cheng ◽  
Zhiwei Guo ◽  
Zhongdong Qian