Numerical Aero-Thermal Analysis of a Rib-Roughened Trailing Edge Cooling Channel at Different Rotation Numbers and Channel Orientations

Author(s):  
Matteo Pascotto ◽  
Alessandro Armellini ◽  
Luca Casarsa ◽  
Sebastian Spring

The present work considers the aero-thermal characterization of a rib-roughened cooling channel for the trailing edge of gas turbine blades, and is based on previous findings from a smooth channel configuration. The passage is characterized by a trapezoidal cross section with high aspect-ratio, radial inlet flow, and coolant discharge at both model tip and trailing side, where seven elongated pedestals are installed. In this study, heat transfer augmentation is achieved by placing inclined squared ribs on the channel central portion. RANS simulations with a SST turbulence model were performed using the commercial solver ANSYS CFX®v14. The numerical tool was first validated on the available experimental data and, subsequently, its capabilities were exploited in a wider range of working conditions, namely at higher rotation speed and different channel orientation. In this way it was possible to highlight the effects that ribs and working conditions have on the development of both flow and thermal fields. The results show that rotation and channel orientation produce contrasting effects. On the rib-roughened wall, rotation/orientation generates an increase/decrease of the heat transfer; conversely, on the trailing side region rotation/orientation has a negative/positive effect on the thermal field.

2013 ◽  
Vol 2013 ◽  
pp. 1-19 ◽  
Author(s):  
Matteo Pascotto ◽  
Alessandro Armellini ◽  
Luca Casarsa ◽  
Claudio Mucignat ◽  
Pietro Giannattasio

The flow field inside a cooling channel for the trailing edge of gas turbine blades has been numerically investigated with the aim to highlight the effects of channel rotation and orientation. A commercial 3D RANS solver including a SST turbulence model has been used to compute the isothermal steady air flow inside both static and rotating passages. Simulations were performed at a Reynolds number equal to 20000, a rotation number (Ro) of 0, 0.23, and 0.46, and channel orientations ofγ=0∘, 22.5°, and 45°, extending previous results towards new engine-like working conditions. The numerical results have been carefully validated against experimental data obtained by the same authors for conditionsγ=0∘and Ro = 0, 0.23. Rotation effects are shown to alter significantly the flow field inside both inlet and trailing edge regions. These effects are attenuated by an increase of the channel orientation fromγ=0∘to 45°.


Author(s):  
Matteo Pascotto ◽  
Alessandro Armellini ◽  
Luca Casarsa ◽  
Pietro Giannattasio ◽  
Claudio Mucignat

The flow field inside a trailing edge (TE) cooling channel for gas turbine blades has been numerically investigated with reference to the effects of channel rotation and orientation. The channel consists of a single passage with high aspect ratio cross-section. The flow entering from the hub is discharged through both the channel tip and inter-pedestal passages at the TE. A commercial 3D RANS solver including a κ–ω SST turbulence model has been used to simulate the isothermal steady airflow at 20000 Reynolds number in the case of static channel and for two rotation numbers (Ro = 0.23, 0.46) at varying the channel orientation with respect to the rotation axis (γ = 0°, γ = 22.5°, γ = 45°). The present work extends a previous experimental analysis performed by the authors on the same channel geometry, the results of which are used to validate the numerical model. Rotation effects are shown to alter significantly the distribution of both the mass flow in the inlet duct and the velocity along the channel height. This causes remarkable modifications of the 3D flow structures in the inter-pedestal passages and, in particular, the disappearance of the horseshoe vortices from the pedestal upstream face. Changing the channel orientation results in an attenuation of the rotation effects in the inlet duct and in the hub region of the TE.


Author(s):  
Balamurugan Srinivasan ◽  
Anand Dhamarla ◽  
Chandiran Jayamurugan ◽  
Amarnath Balu Rajan

The increasing demands of better efficiency of modern advanced gas turbine require higher turbine inlet temperatures, which gives great challenges to turbine blade designers. However, the temperature limits of turbine blade material are not high enough to ensure its survival in such incredible operating temperature. Hence, both internal and external cooling approaches have been developed and widely used in today’s turbine blade. To internal cooling problems, a variety of cooling enhancement approaches, such as impingement and turbulators, are employed in order to meet the different needs in leading, middle and trailing region. One of the most critical parts in turbine blade is trailing edge where it is hard to cool due to its narrow shape. Pin-fins are widely used to cool the trailing edge of rotor and stator blades of gas turbine engine. Pin-fins offer significant heat transfer enhancement, they are relatively easy to fabricate and offer structural support to the hollow trailing edge region. The flow physics in a pin-fin roughened channel is very complicated and three-dimensional. In this work, we have studied the effect of channel orientation on heat transfer in a rotating wedge-shaped cooling channel using numerical methods. Qiu [1] studied experimentally heat transfer effects of 5 different angles of wedge shaped channel orientation for the inlet Reynolds number (5100 to 21000) and rotational speed (zero to 1000 rpm), which results in the inlet Rotation number variation from 0 to 0.68. They observed that compared to the non-rotating condition, there is about 35% overall heat transfer enhancement under highest rotation number. The above said results are validated using current studies with Computational Fluid Dynamics (CFD) revealed that rotation increases significantly the heat transfer coefficient on the trailing surface and reduces the heat transfer coefficient on the leading surface. This is due to the higher velocities associated with the converging geometry near trailing surface.


Author(s):  
A. K. Sleiti ◽  
J. S. Kapat

Prediction of three-dimensional flow field and heat transfer in a two pass rib-roughened square internal cooling channel of turbine blades with rounded staggered ribs rotating at high rotation and density ratios is the main focus of this study. Rotation, buoyancy, ribs, and geometry affect the flow within these channels. The full two-pass channel with bend and with rounded staggered ribs with fillets (e/Dh = 0.1 and P/e = 10) as tested by Wagner et. al [1992] is investigated. RSM is used in this study and enhanced wall treatment approach to resolve the near wall viscosity-affected region. RSM model was validated against available experimental data (which are primarily at low rotation and buoyancy numbers). The model was then used for cases with high rotational numbers (0.24, 0.475, 0.74 and 1) and high-density ratios (0.13, 0.23, and 0.3). Particular attention is given to how secondary flow, Reynolds stresses, turbulence intensity, and heat transfer are affected by coriolis and buoyancy/centrifugal forces caused by high levels of rotation and density ratios. A linear correlation for 4-side-average Nusselt number as a function of rotation number is derived.


Author(s):  
Szu-Chi Huang ◽  
Yao-Hsien Liu

Heat transfer in a leading edge, triangular-shaped cooling channel with three channel orientations under high rotation numbers is investigated in this study. Continuous ribs and V-shaped ribs (P/e = 9, e/Dh = 0.085), both placed at an angle (α = 45 deg) to the mainstream flow, are applied on the leading and trailing surfaces. The Reynolds number range is 15,000–25,000 and the rotation number range is 0–0.65. Effects of high rotation number on heat transfer with three angles of rotation (90 deg, 67.5 deg, and 45 deg) are tested. Results show that heat transfer is influenced by the combined effects of rib and channel orientation. When the rotation number is smaller than 0.4, rotation causes a decrease in the average Nusselt number ratios on the leading surface at a channel orientation of 90 deg. Heat transfer is enhanced gradually on the leading surface when the channel orientation varies from 90 deg to 45 deg for both ribbed cases. The highest heat transfer enhancement due to rotation is found at the highest rotation number of 0.65.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3954
Author(s):  
Liang Xu ◽  
Qicheng Ruan ◽  
Qingyun Shen ◽  
Lei Xi ◽  
Jianmin Gao ◽  
...  

Traditional cooling structures in gas turbines greatly improve the high temperature resistance of turbine blades; however, few cooling structures concern both heat transfer and mechanical performances. A lattice structure (LS) can solve this issue because of its advantages of being lightweight and having high porosity and strength. Although the topology of LS is complex, it can be manufactured with metal 3D printing technology in the future. In this study, an integral optimization model concerning both heat transfer and mechanical performances was presented to design the LS cooling channel with a variable aspect ratio in gas turbine blades. Firstly, some internal cooling channels with the thin walls were built up and a simple raw of five LS cores was taken as an insert or a turbulator in these cooling channels. Secondly, relations between geometric variables (height (H), diameter (D) and inclination angle(ω)) and objectives/functions of this research, including the first-order natural frequency (freq1), equivalent elastic modulus (E), relative density (ρ¯) and Nusselt number (Nu), were established for a pyramid-type lattice structure (PLS) and Kagome-type lattice structure (KLS). Finally, the ISIGHT platform was introduced to construct the frame of the integral optimization model. Two selected optimization problems (Op-I and Op-II) were solved based on the third-order response model with an accuracy of more than 0.97, and optimization results were analyzed. The results showed that the change of Nu and freq1 had the highest overall sensitivity Op-I and Op-II, respectively, and the change of D and H had the highest single sensitivity for Nu and freq1, respectively. Compared to the initial LS, the LS of Op-I increased Nu and E by 24.1% and 29.8%, respectively, and decreased ρ¯ by 71%; the LS of Op-II increased Nu and E by 30.8% and 45.2%, respectively, and slightly increased ρ¯; the LS of both Op-I and Op-II decreased freq1 by 27.9% and 19.3%, respectively. These results suggested that the heat transfer, load bearing and lightweight performances of the LS were greatly improved by the optimization model (except for the lightweight performance for the optimal LS of Op-II, which became slightly worse), while it failed to improve vibration performance of the optimal LS.


2019 ◽  
Vol 9 (14) ◽  
pp. 2900
Author(s):  
Qi Jing ◽  
Yonghui Xie ◽  
Di Zhang

The trailing edge regions of high-temperature gas turbine blades are subjected to extremely high thermal loads and are affected by the external wake flow during operation, thus creating great challenges in internal cooling design. With the development of cooling technology, the dimple and protrusion have attracted wide attention for its excellent performance in heat transfer enhancement and flow resistance reduction. Based on the typical internal cooling structure of the turbine blade trailing edge, trapezoidal cooling channels with lateral extraction slots are modeled in this paper. Five channel outlet configurations, i.e., no second passage (OC1), radially inward flow second passage (OC2), radially outward flow second passage (OC3), top region outflow (OC4), both sides extractions (OC5), and three dimple/protrusion arrangements (all dimple, all protrusion, dimple–protrusion staggered arrangement) are considered. Numerical investigations are carried out, within the Re range of 10,000–100,000, to analyze the flow structures, heat transfer distributions, average heat transfer and friction characteristics and overall thermal performances in detail. The results show that the OC4 and OC5 cases have high heat transfer levels in general, while the heat transfer deterioration occurs in the OC1, OC2, and OC3 cases. For different dimple/protrusion arrangements, the protrusion case produces the best overall thermal performance. In conclusion, for the design of trailing edge cooling structures with lateral slots, the outlet configurations of top region outflow and both sides extractions, and the all protrusion arrangement, are recommended.


Author(s):  
Mohammad Taslim ◽  
Joseph S. Halabi

Local and average heat transfer coefficients and friction factors were measured in a test section simulating the trailing edge cooling cavity of a turbine airfoil. The test rig with a trapezoidal cross sectional area was rib-roughened on two opposite sides of the trapezoid (airfoil pressure and suction sides) with tapered ribs to conform to the cooling cavity shape and had a 22-degree tilt in the flow direction upstream of the ribs that affected the heat transfer coefficients on the two rib-roughened surfaces. The radial cooling flow traveled from the airfoil root to the tip while exiting through 22 cooling holes along the airfoil trailing edge. Two rib geometries, with and without the presence of the trailing-edge cooling holes, were examined. The numerical model contained the entire trailing-edge channel, ribs and trailing-edge cooling holes to simulate exactly the tested geometry. A pressure-correction based, multi-block, multi-grid, unstructured/adaptive commercial software was used in this investigation. Realizable k–ε turbulence model in conjunction with enhanced wall treatment approach for the near wall regions, was used for turbulence closure. The applied thermal boundary conditions to the CFD models matched the test boundary conditions. Comparisons are made between the experimental and numerical results.