Heat Transfer Enhancement and Pressure Loss Characteristics of Zig-Zag Channel With Dimples and Protrusions

Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Mary Anne Alvin

This paper described a detailed experimental study to explore an internal cooling passage that mimic a “zig-zag” pattern. There are four passages connected by 110° turning angle in a periodic fashion, hence the name. Experiments are performed in a scaled-up test channel with a cross-section of 63.5mm by 25.4mm, corresponding to the aspect ratio of 2.5:1. Compared to the conventional straight internal cooling passages, the zig-zag channel with several turns will generate additional secondary vortices while providing longer flow path that allows coolant to remove much more heat load prior to discharge into the hot mainstream. Surface features, (1) dimples, and (2) protrusions are added to the zig-zag channel to further enhance the heat transfer, while contributed to larger wetted area. The experiment utilizes the well-established transient liquid crystal technique to determine the local heat transfer coefficient distribution of the entire zig-zag channel. Protrusions exhibit higher heat transfer enhancement than that of dimples. However, both designs proved to be inferior compared to the rib-turbulators. Pressure loss in these test channels is approximately twofold higher than that of straight smooth test channel due to the presence of turns; but the pressure loss is lower than the zig-zag channel with rib-turbulators. The result revealed that one advantage of having either protrusions or dimples as these surface elements will resulted in gradual and more uniform increment of heat transfer throughout the entire channel compared to previous test cases.

2018 ◽  
Vol 140 (10) ◽  
Author(s):  
Andrew F. Chen ◽  
Hao-Wei Wu ◽  
Nian Wang ◽  
Je-Chin Han

Experimental investigation on rotation and turning vane effects on heat transfer was performed in a two-pass rectangular internal cooling channel. The channel has an aspect ratio of AR = 2:1 and a 180 deg tip-turn, which is a scaled up model of a typical internal cooling passage of gas turbine airfoils. The leading surface (LS) and trailing surface (TS) are roughened with 45 deg angled parallel ribs (staggered P/e = 8, e/Dh = 0.1). Tests were performed in a pressurized vessel (570 kPa) where higher rotation numbers (Ro) can be achieved with a maximum Ro = 0.42. Five Reynolds numbers (Re) were examined (Re = 10,000–40,000). At each Reynolds number, five rotational speeds (Ω = 0–400 rpm) were considered. Results showed that rotation effects are stronger in the tip regions as compared to other surfaces. Heat transfer enhancement up to four times was observed on the tip wall at the highest rotation number. However, heat transfer enhancement is reduced to about 1.5 times with the presence of a tip turning vane at the highest rotation number. Generally, the tip turning vane reduces the effects of rotation, especially in the turn portion.


Author(s):  
Pavin Ganmol ◽  
Minking K. Chyu ◽  
Mary Anne Alvin

The design geometry and transport phenomena associated with the tip internal cooling can be very complex and has been little studied. Internal cooling channel near a tip region typically inherits a sharp, 180-degree, turn and little or no enhancement installation exists. To explore potential design for enhancement cooling, a series of experiments are performed to investigate the heat transfer enhancement by placing different pin-fins configurations in the tip-turn region of a two-pass channel with a 180-degree sharp turn. Transient liquid crystal technique is applied to acquire detailed local heat transfer data both on the channel surface and pin elements, for Reynolds number between 13,000 and 28,000. Present results suggest that the pin-fins can enhance heat transfer up to 2.3 fold in the tip-turn region and up to 1.3 fold for the entire channel. The presence of the pin-fins also changes the flow pattern in the post turn region which is resulting in more evenly distributed heat transfer downstream of the turn.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Tom I.-P. Shih ◽  
Mary Anne Alvin

Heat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W = 76.2 mm, E = 25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D = 6.35 mm = ¼E, three different pin-fin height-to-diameter ratios, H/D = 4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin tip and one of the endwalls, i.e., C/D = 0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the unobstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain the distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin tip and the endwall has a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D, leads to lower heat transfer enhancement and pressure drop. However, C/D = 1, i.e., H/D = 3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D = 0 and C/D = 2, i.e., H/D = 4 or 2, respectively.


Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Tom I.-P. Shih ◽  
Mary Anne Alvin

Heat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W = 101.6 mm, E = 25.4 mm) simulates an internal cooling passage of wide aspect ratio (4:1) in a gas turbine airfoil. With a given pin diameter, D = 6.35 mm = 1/4 E, three different pin-fin height-to-diameter ratios, H/D = 4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin-tip and one of the endwalls, i.e. C/D = 0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the un-obstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin-tip and the endwall have a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D leads to lower heat transfer enhancement and pressure drop. However, C/D = 1, i.e. H/D = 3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D = 0 and C/D = 2, i.e. H/D = 4 or 2, respectively.


Author(s):  
M. K. Chyu ◽  
Y. Yu ◽  
H. Ding ◽  
J. P. Downs ◽  
F. O. Soechting

The present study evaluates an innovative approach for enhancement of surface heat transfer in a channel using concavities, rather than protruding elements. Serving as a vortex generator, a concavity is expected to promote turbulent mixing in the flow bulk and enhance the heat transfer. Using a transient liquid crystal imaging system, local heat transfer distribution on the surface roughened by an staggered array based on two different shapes of concavities, i.e. hemispheric and tear-drop shaped, have been obtained, analyzed and compared. The results reveal that both concavity configurations induce a heat transfer enhancement similar to that of continuous rib turbulators, about 2.5 times their smooth counterparts 10,000 ≤ Re ≤ 50,000. In addition, both concavity arrays reveal remarkably low pressure losses that are nearly one-half the magnitudes incurred with protruding elements. In turbine cooling applications, the concavity approach is particularly attractive in reducing system weight and ease of manufacturing.


Author(s):  
J.-J. Hwang ◽  
C.-S. Cheng ◽  
Y.-P. Tsia

An experimental study has been performed to measure local heat transfer coefficients and static well pressure drops in leading-edge triangular ducts cooled by wall/impinged jets. Coolant provided by an array of equally spaced wall jets is aimed at the leading-edge apex and exits from the radial outlet. Detailed heat transfer coefficients are measured for the two walls forming the apex using transient liquid crystal technique. Secondary-flow structures are visualized to realize the mechanism of heat transfer enhancement by wall/impinged jets. Three right-triangular ducts of the same altitude and different apex angles of β = 30 deg (Duct A), 45 deg (Duct B) and 60 deg (Duct C) are tested for various jet Reynolds numbers (3000≦Rej≦12600) and jet spacings (s/d = 3.0 and 6.0). Results show that an increase in Rej increases the heat transfer on both walls. Local heat transfer on both walls gradually decreases downstream due to the crossflow effect. At the same Rej, the Duct C has the highest wall-averaged heat transfer because of the highest jet center velocity as well as the smallest jet inclined angle. Moreover, the distribution of static pressure drop based on the local through flow rate in the present triangular duct is similar to that that of developing straight pipe flows. Average jet Nusselt numbers on the both walls have been correlated with jet Reynolds number for three different duct shapes.


Author(s):  
Ken-Ichiro Takeishi ◽  
Robert Krewinkel ◽  
Yutaka Oda ◽  
Yuichi Ichikawa

In the near future, when designing and using Double Wall Airfoils, which will be manufactured by 3D printers, the positional relationship between the impingement cooling nozzle and the heat transfer enhancement ribs on the target plate naturally becomes more accurate. Taking these circumstances into account, an experimental study was conducted to enhance the heat transfer of the wall jet region of a round impingement jet cooling system. This was done by installing circular ribs or vortex generators (VGs) in the impingement cooling wall jet region. The local heat transfer coefficient was measured using the naphthalene sublimation method, which utilizes the analogy between heat and mass transfer. As a result, it was clarified that, within the ranges of geometries and Reynolds numbers at which the experiments were conducted, it is possible to improve the averaged Nusselt number Nu up to 21% for circular ribs and up to 51% for VGs.


Sign in / Sign up

Export Citation Format

Share Document