Experimental Study on Flow Visualizing and Heat Transfer Characteristic of Pulsating Heat Pipe

Author(s):  
Li Jia ◽  
Dayan Yin

The flow of looped pulsating heat pipe was studied by a visualizing experiment, and the PHP is made of high quality glass capillary tube. Under different fill ratio, heat transfer rate and many other influence factors, the flow patterns were observed in the start-up, transition and stable stage. The experimental results indicate that bulk flow, transition flow and annular flow are the major flow patterns in PHP. Under different fill ratios and heat transfer rate, the flow pattern in PHP is transferred form bulk flow to semi-annual flow and annual flow, and the performance of heat transfer is improved. In the experiment, nuclear boiling, the convergence and break up of liquid-plug and vapor-slug were observed. The influence characterization has been done for the variation of fill ration, heat transfer rate, non-condensable gas and inclination angle. The experimental results indicate that the total heat resistant of PHP is increased with fill ratio, and heat transfer rate achieves optimum at filling rate 50%; the heat resistance is decreased with heat transfer rate, and non-condensable gas also has significant influence on it. The temperature of tubes in heating, condensing and observe sections were recorded, The fluctuation of heat pipe wall temperature was analysed, and the phenomena of suddently increase or decrease of temperature, the unregular fluctuation of temperature were analyzed. Otherwise the response time under different conditions was also analyzed.


Author(s):  
Li Jia ◽  
Yan Li

Experimental research was conducted to understand heat transfer characteristics of pulsating heat pipe in this paper. The PHP is made of high quality glass capillary tube. The heat transfer rate and many other influence factors, the flow patterns were observed in the start-up, transition and stable stage under different fill ratio. The effects of heating position on heat transfer were discussed. The experimental results indicate that no annular flow appeares in top heating condition. The flow pattern in PHP is transferred form bulk flow to semi-annual flow and annual flow, and the performance of heat transfer is improved for down heating case under different fill ratios and heat transfer rate. The experimental results show that the total heat resistant of PHP is increased with fill ratio, and heat transfer rate achieves optimum at filling rate 50%. But for pulsating heat pipe with changing diameters the thermal resistance is higher than that with uniform diameters.



Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 595
Author(s):  
Mahir Faris Abdullah ◽  
Rozli Zulkifli ◽  
Hazim Moria ◽  
Asmaa Soheil Najm ◽  
Zambri Harun ◽  
...  

Impinging jets are considered to be a well-known technique that offers high local heat transfer rates. No correlation could be established in the literature between the significant parameters and the Nusselt number, and investigation of the interactions between the correlated factors has not been conducted before. An experimental analysis based on the twin impingement jet mechanism was achieved to study the heat transfer rate pertaining to the surface plate. In the current paper, four influential parameters were studied: the spacing between nozzles, velocity, concentration of Nano solution coating and nozzle-plate distance, which are considered to be effective parameters for the thermal conductivity and the heat transfer coefficient of TiO2 nanoparticle, an X-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM) analysis were done, which highlighted the structure and showed that the nanosolution coated the surface homogenously. Moreover, a comparison was done for the experimental results with that of the predicted responses generated by the Design Expert software, Version 7 User’s Guide, USA. A response surface methodology (RSM) was employed to improve a mathematical model by accounting for a D-optimal design. In addition, the analysis of variance (ANOVA) was employed for testing the significance of the models. The maximum Nu of 91.47, where H = S = 1 cm; Reynolds number of 17,000, and TiO2 nanoparticle concentration of 0.5% M. The highest improvement rate in Nusselt was about 26%, achieved with TiO2 Nanoparticle, when S = 3 cm, H = 6 cm and TiO2 nanoparticle = 0.5 M. Furthermore, based on the statistical analysis, the expected values were found to be in satisfactory agreement with that of the empirical data, which was conducted by accounting for the proposed models’ excellent predictability. Multivariate approaches are very useful for researchers, as well as for applications in industrial processes, as they lead to increased efficiency and reduced costs, so the presented results of this work could encourage the overall uses of multivariate methods in these fields. Hypotheses: A comparison was done for the predicted responses generated by the Design Expert software with the experimental results and then studied to verify the following hypotheses: ► Preparation of three concentrations of TiO2 nanosolution was done and studied. ► The heat transfer rate could be increased by surface coating with TiO2 nanoparticle. ► The heat transfer could be improved by the impingement jet technique with suitable adjustments.





1973 ◽  
Vol 25 (3) ◽  
pp. 1115-1117
Author(s):  
V. Ya. Sasin ◽  
A. Ya. Shelginskii


Author(s):  
Shota Sato ◽  
Shigeki Hirasawa ◽  
Tsuyoshi Kawanami ◽  
Katsuaki Shirai

We experimentally study the thermal conductance of single-tube and loop heat pipes for a solar collector. The evaporator of the heat pipe is 1 m long, 6 mm in diameter and has 30° inclination. The thermal conductance is defined as the heat transfer rate divided by the temperature difference between the evaporator-wall and the condenser-wall. Effects of heat transfer rate, saturation temperature of the working fluid, liquid filling ratio, inclination angle, and position of the evaporator on the thermal conductance are examined. We found that the thermal conductance of the 30°-inclined loop heat pipe with an upper-evaporator is 40–50 (W/K), which is 1.8 times higher than that of the vertical loop type and 3 times higher than that of the single-tube type. Thus, the inclined loop heat pipe is preferable for a solar collector. There is an optimum liquid filling ratio. When the liquid filling ratio is too small, a dry-out portion appears in the evaporator. When the liquid filling ratio is too large, the liquid flows in the condenser to decrease heat transfer area. Also we numerically analyze the thermal conductance of a vertical loop heat pipe.



2015 ◽  
Vol 7 (2) ◽  
pp. 168781401456781 ◽  
Author(s):  
S Boothaisong ◽  
S Rittidech ◽  
T Chompookham ◽  
M Thongmoon ◽  
Y Ding ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document