scholarly journals Integration of a Pulsating Heat Pipe in a Flat Plate Heat Sink

Author(s):  
Mitchell P. Hoesing ◽  
Gregory J. Michna

The ongoing development of faster and smaller electronic components has led to a need for new technologies to effectively dissipate waste thermal energy. The pulsating heat pipe (PHP) shows potential to meet this need, due to its high heat flux capacity, simplicity, and low cost. A 20-turn flat plate PHP was integrated into an aluminum flat plate heat sink with a simulated electronic load. The PHP heat sink used water as the working fluid and had 20 parallel channels with dimensions 2 mm × 2 mm × 119 mm. Experiments were run under various operating conditions, and thermal resistance of the PHP was calculated. The performance enhancement provided by the PHP was assessed by comparing the thermal resistance of the heat sink with no working fluid to that of it charged with water. Uncharged, the PHP was found to have a resistance of 1.97 K/W. Charged to a fill ratio of approximately 75% and oriented vertically, the PHP achieved a resistance of .49 K/W and .53 K/W when the condenser temperature was set to 20°C and 30°C, respectively. When the PHP was tilted to 45° above horizontal the PHP had a resistance of .76 K/W and .59 K/W when the condenser was set 20°C and 30°C, respectively. The PHP greatly improves the heat transfer properties of the heat sink compared to the aluminum plate alone. Additional considerations regarding flat plate PHP design are also presented.

2013 ◽  
Vol 772 ◽  
pp. 480-486 ◽  
Author(s):  
Chen Wang ◽  
Zhong Liang Liu ◽  
Guang Meng Zhang

A copper-water flat plate heat pipe with intersected micro-grooves was developed for cooling electronic devices in this paper. The effects of heat flux, working fluid filling ratio and inclination angles on thermal performance of the flat plate heat pipe was tested and investigated. The laboratory tests show the optimal filling ratio of the heat pipe is about 65%. Excellent thermal performance is also observed in unfavorable titled positions including vertical and anti-gravity orientation at 65%. The smallest overall thermal resistance is obtained in horizontal position and the maximal thermal resistance is observed in vertical position. The influence of inclination angles on thermal performance of the heat pipe in both axial direction and radial direction is also investigated. As the heat pipe is tilted, the ability of temperature leveling in radial direction is enhanced, nevertheless, the capacity of heat transfer in radial direction decreased at the same time.


2018 ◽  
Vol 207 ◽  
pp. 04004
Author(s):  
Radovan Nosek ◽  
Tatiana Liptáková ◽  
Libor Trško ◽  
Zuzana Kolková ◽  
Milan Malcho ◽  
...  

You Heat pipe is a high efficiency heat transfer element, depends on the evaporation, condensation and circulation of inside working fluid. The working fluid of a high temperature pulsating heat pipe is generally alkali metals, and sodium heat pipe can operate in range of 500-1100°C. In order to investigate terminal velocity of working fluid, the glass pulsating heat pipe was produced for experimental purposes. The experiment was carried out, in order to simulate real operating conditions in range of 500-1100°C. Sudden boiling of liquid sodium (b.p. = 883°C at 1 atm) inside the all quartz-made heat pipe results in high-temperature reaction of sodium vapour with the inner wall surface. The reaction became more aggressive with increasing vapour temperature and resulted in heat pipe explosion. The evaluation of damage character is analysed in this paper.


Author(s):  
Mehdi Taslimifar ◽  
Maziar Mohammadi ◽  
Mohammad Hassan Saidi ◽  
Hossein Afshin ◽  
Mohammad Behshad Shafii ◽  
...  

In the present research an experimental investigation is performed to explore the effects of working fluid, heat input, ferrofluid concentration, magnets location, and inclination angle on the thermal performance of an Open Loop Pulsating Heat Pipe (OLPHP). Obtained results show that using ferrofluid can improve the thermal performance and applying a magnetic field on the water based ferrofluid decreases the thermal resistance. It shows that at an inclination angle of the OLPHP to be zero, the thermal performance of the present OLPHP reduces. Best heat transfer capability was achieved at 67.5 degree relative to horizontal axis for all of working fluids. Variation of the magnets location leads to a different thermal resistance in the OLPHP charged with ferrofluid.


2017 ◽  
Vol 865 ◽  
pp. 137-142
Author(s):  
Somchai Maneewan ◽  
Chantana Punlek ◽  
Hoy Yen Chan ◽  
Atthakorn Thongtha

Heat transfer performances of a pulsating heat pipe (PHP) having internal and external diameter with 4.5 mm and 6 mm with various contents of refrigerant are experimentally investigated. The working fluid as R404A refrigerant was filled in the volume ratios from 0% to 80% and the heat input was controlled in the range from 10 W to 80 W. Obtained results exhibited the ability of R404A refrigerant can enhance the thermal performance in steady state condition. The average temperature difference of the evaporating section and condensing section in the 80% filling volume ratio decreased from 9.5 °C to 2.5 °C when the heating power increase from 10 W to 80 W. The thermal resistance of evaporator and condenser decreased with an increase of the heat input as well. For other filling volume ratios, the trend of temperature difference and thermal resistance was similar to that of the 80% volume filling ratio. Considering the same heat input, the highest heat transfer performance was found at the 80% volume filling ratio. Refrigerant with a relatively low dynamic consistency can lead to relatively high velocity in the PHP that can reduce the temperature difference between the evaporating section and condensing section.


Author(s):  
Ming Zhang ◽  
Zhongliang Liu ◽  
Chen Wang

An effective thermal spreader can achieve uniform heat flux distribution and thus enhance heat dissipation of heat sinks. Flat plate heat pipe is one of the highly effective thermal spreaders. Magnetic fluid is a special fluid that can be made flow by traveling force of magnetic field. Therefore, the magnetic fluid is suitable for using as the working fluid of flat plate heat pipes that have a very small gap between evaporation and condensation surfaces. In this paper, we prepared a disk-shaped wickless flat plate heat pipe, and the distance between evaporation and condensation surfaces is 1 mm. From experimental study, the effects of heat flux and working fluid ratio on the performance of the flat plate heat pipe are obtained and the working performance of the magnetic fluid is compared with that of the water flat pate heat pipe of the same geometry structure.


2015 ◽  
Vol 789-790 ◽  
pp. 422-425
Author(s):  
Fun Liang Chang ◽  
Yew Mun Hung

Micro heat pipe is a two-phase heat transfer device offering effective high heat-flux removal in electronics cooling. Essentially, micro heat pipe relies on the phase change processes, namely evaporation and condensation, and the circulation of working fluid to function as heat transfer equipment. The vast applications of micro heat pipe in portable appliances necessitate its functionality under different orientations with respect to gravity. Therefore, its thermal performance is strongly related to its orientation. By incorporating solid wall conduction, together with the continuity, momentum, and energy equations of the working fluid, a mathematical model is developed to investigate the heat and fluid flow characteristics of inclined micro heat pipes. We investigate both the favorable and adverse effects of gravity on the circulation rate which is intimately related to the thermal performance of micro heat pipes. The effects of gravity, through the angle of inclination, on the circulation strength and heat transport capacity are analysed. This study serves as a useful analytical tool in the micro heat pipe design and performance analysis, associated with different inclinations and operating conditions.


2016 ◽  
Vol 851 ◽  
pp. 292-298
Author(s):  
Niti Kammuang-Lue ◽  
Deuansavanh Phommavongsa ◽  
Kritsada On-Ai ◽  
Phrut Sakulchangsatjatai ◽  
Pradit Terdtoon

Objective of this study is to experimentally investigate the effect of centrifugal accelerations on thermal resistance of the rotating closed-loop pulsating heat pipe (RCLPHP). The RCLPHPs were made of a copper tube with internal diameter of 1.50 and 1.78 mm and bent into flower’s petal-shape and arranged into a circle with 11 turns. The evaporator section located at the outer end of the bundle while the condenser section placed around the center of the RCLPHP with no adiabatic section. Both sections had an identical length of 50 mm. R123, and ethanol was filled as working fluid respectively. The RCLPHP was installed on the test rig and it was rotated by the DC motor at the centrifugal acceleration of 0.5, 1, 3, 5, 10, and 20 times of the gravitational acceleration considering at the connection between the evaporator and condenser section. Heat input was generated by electrical annular-plate heaters and varied from 30 to 50, 100, 150, and 200 W. Ceramic papers, wooden plate, and insulation sheet were consecutively attached on the outer side of the heaters in order to prevent the heat loss from the heater. It can be concluded that when the centrifugal acceleration increases, the thermal resistance continuously decreases since the condensate flows back to the evaporator section more rapidly.


Author(s):  
Gerardo Carbajal ◽  
C. B. Sobhan ◽  
G. P. Peterson

A numerical analysis of the evaporation process in a flat plate heat pipe (FPHP) is presented. Three different heat flux configurations were applied at the evaporator section: parabolic, linear and constant; and three different wick thicknesses were evaluated. A two-dimensional explicit Finite Difference Model was used to conduct the transient computational analysis of the heat pipe. The results indicate that the vaporization rate was more intense at the evaporator for the parabolic heat flux distribution, than for either the linear or constant heat flux distributions. The velocity field is nearly identical to the shape of the input heat flux distribution. The maximum Mach number for all the cases analyzed was low, indicating that the incompressible flow assumption in the vapor was valid. The modeling results also indicated that the thickness of the heat pipe wick was a significant factor in the determination of the overall thermal resistance, with the resulting temperature drop proportional to the thickness of the wick. Typical distributions of the field variables, particularly the temperature in the wall, and the temperature, velocity and pressure in the wick and the vapor core of the flat plate heat pipe are also presented and discussed.


2009 ◽  
Vol 33 (7) ◽  
pp. 1100-1105 ◽  
Author(s):  
Zhang Ming ◽  
Liu Zhongliang ◽  
Ma Guoyuan ◽  
Cheng Shuiyuan

Author(s):  
Chang-Nian Chen ◽  
Ji-Tian Han ◽  
Wei-Ping Gong ◽  
Tien-Chien Jen

High heat flux is very dangerous for electronic heat transfer, such as IGBT (Insulated Gate Bipolar Transistor) cooling. In order to explore and master the heat transfer and hydraulic characteristics for IGBT cooling, experiments have been carried out to study the situation mentioned above in a flat plate heat sink, which was designed for high heat flux IGBT cooling. The geometrical parameters of the test section are as follows: outline dimension 229 mm × 124 mm × 30 mm; flow channels of 229 mm × 3 mm × 4 mm in total of 20. The experiments performed at atmospheric pressure and with inlet temperatures of 25–35°C, heat fluxes of 3.5–18.9 kW/m2. The influence of temperatures, heat fluxes on IGBT surface temperature and the cooling effect of the liquid cold plate have been investigated under a range of flow rates of 280–2300 kg/m2s. It was found that the heat transfer enhancement was very obvious using this kind of small sized channel for IGBT cooling, which was tens of times of the effect than air cooling or triple of the effect than that in normal sized channels. And the heat transfer enhancement increases with increasing heat fluxes and flow rates, while it decreases with increasing inlet temperatures. Most of the experimental results show good cooling effect as expected. However, it is dangerous for the cooling system under high heat fluxes when the system starts or stops suddenly, when the Respond Time (RT) is less than 5 seconds to cut off heated power. Also, the cooling performance is bad when the heat fluxes increased greatly, which is considered as abnormal situation in operating. The effect on IGBT surface temperature of heat flux is more obvious when the average Nusselt Number is smaller. For hydraulic characteristics observed, it was found that the flow friction increased with flow rates increasing, but the pressure drops of heated flow channels ahead were slightly larger than those back, especially under large flow rates conditions. That is because the temperatures of flow heated in channels ahead are lower than those back, which causes the fluid viscosity to be higher. At last, this paper suggested a series of method for enhancing heat transfer in flat plate heat sink, and also gave some ways to avoid heat transfer dangerous situations for IGBT cooling, which can provide a basis for thermodynamic and hydraulic calculation of flat plate heat sink design and lectotype.


Sign in / Sign up

Export Citation Format

Share Document