Effect of Temperature on Damping in Shell and Tube Heat Exchangers

Author(s):  
Ali Roheim El-Ghalban ◽  
Qamar Iqbal ◽  
Shahab Khushnood ◽  
M. Arshad Qureshi ◽  
M. Shahid Khalil

Flow-induced vibration in heat exchangers has been a key source of concern in the process, power generation and nuclear industry for several decades. Many incidents of failure of heat exchangers due to apparent flow-induced vibration have been reported. Design of tube bundles with loosely supported tubes in baffles for process shell and tube heat exchanger and steam generator needs estimation of energy dissipation mechanisms or damping for a safer and long term operation. Damping has a major influence on the flow induced vibrations and is dependant on a variety of factors such as mechanical properties of the tube material, geometry and number of intermediate supports, the physical properties of shell-side fluid, type of tube motion, tube frequency, shell-side temperature etc. Various damping mechanisms have been identified and quantified such as Friction damping, Viscous damping, Squeeze film damping, Support damping and Two-Phase damping which affect the performance with respect to flow induced vibration design, including standard design guidelines. But generally the effects of the higher operating temperatures on the various damping mechanisms are neglected in the general design procedure. The operating temperatures play significant role on the contribution of various damping mechanisms. The current paper focuses on the thermal aspects of damping mechanisms subjected to single phase cross-flow in process heat exchangers and formulates the design guidelines for safer design based on experimental and empirical formulations. The research results show that he increase in the temperature results in the increase of the damping. Moreover it found that the natural frequency is higher for lower mass flow rate and lower working pressures and lower temperatures.

1965 ◽  
Vol 8 (32) ◽  
pp. 644-651 ◽  
Author(s):  
Seikan ISHIGAI ◽  
Eiichi NISHIKAWA ◽  
Yoshiaki NAKAYAMA ◽  
Shigeo TANAKA ◽  
Ikuo SAIDA ◽  
...  

1977 ◽  
Vol 99 (3) ◽  
pp. 441-448 ◽  
Author(s):  
K. P. Singh ◽  
M. Holtz

In shell and tube heat exchangers, the triple segmental baffle arrangement has been infrequently used, even though the potential of this baffle system for high thermal effectiveness with low pressure drop is generally known. This neglect seems to stem from the lack of published design guidelines on the subject. Lately, however, with the rapid growth in the size of nuclear heat exchangers, the need to develop unconventional baffling pattern has become increasingly important. A method to effectively utilize the triple segmental concept to develop economical designs is presented herein. The solution technique given in this paper is based on a flow model named “Piecewise Continuous Cosine Model.” The solution procedure easily lends itself to detailed analysis to determine safety against flow-induced vibrations.


2021 ◽  
Author(s):  
praveen math

Abstract Shell and Tube heat exchangers are having special importance in boilers, oil coolers, condensers, pre-heaters. They are also widely used in process applications as well as the refrigeration and air conditioning industry. The robustness and medium weighted shape of Shell and Tube heat exchangers make them well suited for high pressure operations. The aim of this study is to experiment, validate and to provide design suggestion to optimize the shell and tube heat exchanger (STHE). The heat exchanger is made of acrylic material with 2 baffles and 7 tubes made of stainless steel. Hot fluid flows inside the tube and cold fluid flows over the tube in the shell. 4 K-type thermocouples were used to read the hot and cold fluids inlet and outlet temperatures. Experiments were carried out for various combinations of hot and cold water flow rates with different hot water inlet temperatures. The flow conditions are limited to the lab size model of the experimental setup. A commercial CFD code was used to study the thermal and hydraulic flow field inside the shell and tubes. CFD methodology is developed to appropriately represent the flow physics and the procedure is validated with the experimental results. Turbulent flow in tube side is observed for all flow conditions, while the shell side has laminar flow except for extreme hot water temperatures. Hence transition k-kl-omega model was used to predict the flow better for transition cases. Realizable k- epsilon model with non-equilibrium wall function was used for turbulent cases. Temperature and velocity profiles are examined in detail and observed that the flow remains almost uniform to the tubes thus limiting heat transfer. Approximately 2/3 rd of the shell side flow does not surround the tubes due to biased flow contributing to reduced overall heat transfer and increased pressure loss. On the basis of these findings an attempt has been made to enhance the heat transfer by inducing turbulence in the shel l side flow. The two baffles were rotated in opposite direction to each other to achieve more circulation in the shell side flow and provide more contact with tube surface. Various positions of the baffles were simulated and studied using CFD analysis and th e results are summarized with respect to heat transfer and pressure loss.


Author(s):  
W. G. Sim

Two-phase cross flow exists in many shell- and tube heat exchangers such as condensers, evaporators and nuclear steam generators. During the last two decades, research devoted to two-phase flow induced vibrations has increased, mainly driven by the nuclear industry. Flow-induced vibration excitation forces can cause excessive vibration which will result in long-term fretting-wear or fatigue. To avoid potential tube failures in heat exchangers, it is required for designer to have guidelines that incorporate flow-induced vibration excitation forces. The phenomenon of the vibration of tubes in two-phase flow is very complex and depends on factors which are nonexistent in single-phase flows. To understand the fluid dynamic forces acting on a structure subjected to two-phase flow, it is essential to get detailed information about the characteristics of two-phase flow. Pressure distributions generated by two-phase flow over tube surfaces yield more general information than the local velocity distribution. The pressure coefficient distribution obtained by experimental test has been evaluated.


Author(s):  
Qi Xiao ◽  
Ning Yang ◽  
Zhenxing Zhao ◽  
Chunhui Dai ◽  
Jun Wu ◽  
...  

The boiling vapor-liquid flow at the shell side of shell-and-tube heat exchangers was simulated by Euler-Euler transient 3D method in this paper. The mass and heat transfers between the two-phase fluid and heated wall for the subcooled boiling phenomenon were described by the Rensselaer Polytechnic Institute model (RPI model), while the steam condensation within the subcooled liquid was described by the Lee model. Firstly, different turbulence and interfacial force models were evaluated by comparing with the experimental data of Bartolomej (1982). It was found that the turbulence models have minor influence on the temperature and vapor volume fraction distributions. As the bubble size in the subcooled boiling process is small (usually <1 mm), the velocity slip between the vapor bubbles and the liquid is not so important. The simulation results using different drag force models are similar, and the Tomiyama model offers relatively better predictions. The non-drag forces could not significantly improve the accuracy in our simulations. Then the gas-liquid boiling flow at the shell side of shell-and-tube heat exchangers was then simulated. It was found that the water temperature increases almost linearly near the inlet zone, and the increase speed was slowed down when the bulk temperature approached to the saturated point as the boiling process happened more frequently and consumed much heat. The heat exchangers with the triangle and square configurations have similar temperature and vapor distributions. Further analyses for those two kinds of tube configurations are needed.


1965 ◽  
Vol 31 (223) ◽  
pp. 419-426
Author(s):  
Seikan ISHIGAI ◽  
Eiichi NISHIKAWA ◽  
Yoshiaki NAKAYAMA ◽  
Shigeo TANAKA ◽  
Ikuo SAIDA ◽  
...  

Author(s):  
Nitin D. Pagar ◽  
S. H. Gawande

Abstract Shell and tube heat exchangers [STHE] play a very vital role in energy conversion systems, process industries like chemical, pharmaceutical, refineries etc. and in different power plants. For designing shell and tube heat exchangers, the tubes vibrational response (internally) to any random excitations of fluid flow need to be understandable. Also, circumferential inlet pipe or tube at the entrance region of the shell side, generally subject to the fluid thrust in the bends of typical pipe arrangements. It produces loadings forces and moments, leading to unavoidable vibrations. The goal of vibration analysis is to ensure that fatigue damage or fretting wear does not occur, as well as, predicted frequencies, amplitudes shall be within acceptable limits criteria. This paper reports the vibration analysis of different piping arrangement of different end conditions to understand its effects on frequencies and modes so that a designer must mitigate it, at the initial stage. Axial, lateral and torsional vibrations are analyzed for different end conditions. The boundary conditions used are both ends fixed, one end fixed and other end free, both ends free and one end fixed-other end attached to a weight. Analytical procedure is carried out to determine the frequencies for axial, lateral and torsional cases. FEA analysis and experiment using an FFT analyzer is carried out to check the convergence of the results. Very useful results are established which generates the philosophy to protect the pipings from the resonant frequencies subjected to different end conditions.


Sign in / Sign up

Export Citation Format

Share Document