scholarly journals Shell-Side Pressure Drop in the Multi-Baffled Shell-and-Tube Heat Exchangers

1965 ◽  
Vol 8 (32) ◽  
pp. 644-651 ◽  
Author(s):  
Seikan ISHIGAI ◽  
Eiichi NISHIKAWA ◽  
Yoshiaki NAKAYAMA ◽  
Shigeo TANAKA ◽  
Ikuo SAIDA ◽  
...  
1965 ◽  
Vol 31 (223) ◽  
pp. 419-426
Author(s):  
Seikan ISHIGAI ◽  
Eiichi NISHIKAWA ◽  
Yoshiaki NAKAYAMA ◽  
Shigeo TANAKA ◽  
Ikuo SAIDA ◽  
...  

1977 ◽  
Vol 99 (3) ◽  
pp. 441-448 ◽  
Author(s):  
K. P. Singh ◽  
M. Holtz

In shell and tube heat exchangers, the triple segmental baffle arrangement has been infrequently used, even though the potential of this baffle system for high thermal effectiveness with low pressure drop is generally known. This neglect seems to stem from the lack of published design guidelines on the subject. Lately, however, with the rapid growth in the size of nuclear heat exchangers, the need to develop unconventional baffling pattern has become increasingly important. A method to effectively utilize the triple segmental concept to develop economical designs is presented herein. The solution technique given in this paper is based on a flow model named “Piecewise Continuous Cosine Model.” The solution procedure easily lends itself to detailed analysis to determine safety against flow-induced vibrations.


2006 ◽  
Vol 129 (9) ◽  
pp. 1277-1285 ◽  
Author(s):  
Qiu-wang Wang ◽  
Gong-nan Xie ◽  
Bo-tao Peng ◽  
Min Zeng

The heat transfer and pressure drop of three types of shell-and-tube heat exchangers, one with conventional segmental baffles and the other two with continuous helical baffles, were experimentally measured with water flowing in the tube side and oil flowing in the shell side. The genetic algorithm has been used to determine the coefficients of correlations. It is shown that under the identical mass flow, a heat exchanger with continuous helical baffles offers higher heat transfer coefficients and pressure drop than that of a heat exchanger with segmental baffles, while the shell structure of the side-in-side-out model offers better performance than that of the middle-in-middle-out model. The predicted heat transfer rates and friction factors by means of the genetic algorithm provide a closer fit to experimental data than those determined by regression analysis. The predicted corrections of heat transfer and flow performance in the shell sides may be used in engineering applications and comprehensive study. It is recommended that the genetic algorithm can be used to handle more complicated problems and to obtain the optimal correlations.


2013 ◽  
Vol 860-863 ◽  
pp. 754-757
Author(s):  
Can Zheng ◽  
Fei Wang ◽  
Yong Gang Lei

A new type of helical baffles heat exchanger is presented in this paper. Comparative study, through numerical simulation, was undertook between the new helical baffles heat exchanger and segmental baffle board heat exchanger in shell side flow and heat exchange characteristics. Fluid medium in the shell side is air. At the same velocity in the same flow conditions, pressure drop of helical baffles heat exchangers fell by an average of 26.8% compared with segmental baffle board heat exchangers, and the unit pressure drop of the heat transfer ratio of helical baffles heat exchanger increased by an average of 40.6%.


2021 ◽  
pp. 300-300
Author(s):  
Sobhanadri Anantha ◽  
Senthilkumar Gnanamani ◽  
Vivekanandan Mahendran ◽  
Venkatesh Rathinavelu ◽  
Ramkumar Rajagopal ◽  
...  

The inclusion of baffles in a double pipe heat exchanger is becoming increasingly important as it improves the heat exchanger's performance. CFD analysis is used in this paper to investigate the performance of double pipe heat exchangers with and without helical baffles on both shell tube sides. The 3D Computation Fluid Dynamics (CFD) model was created in Solid Works, and the FloEFD software was used to analyze the conjugate Heat Transfer between the heat exchanger's tube and shell sides. Heat transfer characteristic like Outlet temperature of shell and tube are investigated along with pressure drop on shell and tube side. Based on CFD results of Double Pipe Heat exchanger with helical baffle on both shell side and tube side (Type 4) gives the better results than the other type of heat exchangers with an increased pressure drop than the others, results reveals that type 4 outlet temperature of shell side is 8% higher and on tube side it is 5.5% higher, also pressure drop on shell side is 12% higher and on tube side it is 42% higher than the other types.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Shubham Sharma ◽  
Shalab Sharma ◽  
Mandeep Singh ◽  
Parampreet Singh ◽  
Rasmeet Singh ◽  
...  

In this numerical study, the heat transfer performance of shell-and-tube heat exchangers (STHXs) has been compared for two different tube arrangements. STHX having 21 and 24 tubes arranged in the inline and staggered grid has been considered for heat transfer analysis. Shell-and-tube heat exchanger with staggered grid arrangement has been observed to provide lesser thermal stratification as compared to the inline arrangement. Further, the study of variation in the mass flow rate of shell-side fluid having constant tube-side flow rate has been conducted for staggered grid structure STHX. The mass flow rate for the shell side has been varied from 0.1 kg/s to 0.5 kg/s, respectively, keeping the tube-side mass flow rate as constant at 0.25 kg/s. The influence of bulk mass-influx transfer rate on heat transfer efficiency, effectiveness, and pressure drop of shell-tube heat exchangers has been analyzed. CFD results were compared with analytical solutions, and it shows a good agreement between them. It has been observed that pressure drop is minimum for the flow rate of 0.1 kg/s, and outlet temperatures at the shell side and tube side have been predicted to be 40.94°C and 63.63°C, respectively.


Sign in / Sign up

Export Citation Format

Share Document