Comparison of CCFL Experiments Performed in Two Different Models of the Hot Leg of a PWR With Rectangular Cross-Section

Author(s):  
Christophe Valle´e ◽  
Tobias Seidel ◽  
Dirk Lucas ◽  
Akio Tomiyama ◽  
Michio Murase

In order to investigate the two-phase flow behaviour during counter-current flow limitation in the hot leg of a pressurised water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques, therefore, a flat hot leg test section design was chosen. Counter-current flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bar absolute at TOPFLOW. According to the presented review of the literature, very few data is available on flooding in channels with rectangular cross-section, and no experiments were performed in the past in such rectangular models of a hot leg. Usually, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate. Commonly, the non-dimensional superficial velocity (also known as the Wallis parameter) is used to plot the flooding diagram. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length, which was originally defined by Wallis (1969) for counter-current flow limitation in vertical pipes and not in near horizontal channels with rectangular cross-section. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. Because the experimental projects on this subject at the Kobe University and at FZD were launched independently, a detailed comparison of both test facilities is presented. With respect to the CCFL behaviour, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows to perform meaningful comparisons. However, clear differences in the dimensions of the cross-section (H × W = 150 × 10 mm2 in Kobe, 250 × 50 mm2 at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross-sections. The hydraulic diameter, the channel height and the Laplace critical wavelength (leading to the Kutateladze number) were tested. The experimental results obtained in the two test facilities clearly show that the channel height is the suited characteristic length. Finally, the experimental results are compared with similar experiments and empirical correlations for pipes available in the literature. In spite of the scatter of the data and of the different correlations, it was noticed that flooding is reached at slightly lower gas fluxes in the hot leg models with rectangular cross-section compared to pipes.

Author(s):  
Christophe Vallée ◽  
Tobias Seidel ◽  
Dirk Lucas ◽  
Akio Tomiyama ◽  
Michio Murase

In order to investigate the two-phase flow behavior during countercurrent flow limitation in the hot leg of a pressurized water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques; therefore, a flat hot leg test section design was chosen. Countercurrent flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bars absolute at TOPFLOW. According to the presented review of literature, very few data are available on flooding in channels with a rectangular cross section, and no experiments were performed in the past in such flat models of a hot leg. Commonly, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate, using the nondimensional superficial velocity (also known as Wallis parameter) as coordinates. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. A detailed comparison of the test facilities operated at the Kobe University and at FZD is presented. With respect to the CCFL behavior, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows us to perform meaningful comparisons. However, clear differences in the dimensions of the cross section (H×W=150×10 mm2 in Kobe, 250×50 mm2 at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross sections. The hydraulic diameter, the channel height, and the Laplace critical wavelength (leading to the Kutateladze number) were tested. A comparison of our own results with similar experimental data and empirical correlations for pipes available in literature shows that the channel height is the characteristic length to be used in the Wallis parameter for channels with rectangular cross sections. However, some limitations were noticed for narrow channels, where CCFL is reached at lower gas fluxes, as already observed in small scale hot legs with pipe cross sections.


2014 ◽  
Vol 590 ◽  
pp. 613-617
Author(s):  
Mulya Juarsa ◽  
Nandy Putra ◽  
Harinaldi ◽  
Anhar Riza Antariksawan

The Effect of gap size to counter current flow limitation (CCFL) in vertical rectangular channel was studied in this paper. Experiment was conducted by using two vertical plate with 1 mm, 2 mm, and 3 mm narrow gap. The initial temperature of plate was decided at 600oC. Flow rate and temperature of cooling water were controlled about 0.09 L/s and 90oC respectively. Non-dimensional superficial velocity for water is 0.05-0.09 and non-dimensional superficial velocity for vapor is 3.20-3.2. The result shows that the existence of CCFL in the vertical rectangular narrow channels. A new correlation for CCFL base on Wallis has been proposed.


Author(s):  
Christophe Vallée ◽  
Deendarlianto ◽  
Matthias Beyer ◽  
Dirk Lucas ◽  
Helmar Carl

Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.


Author(s):  
Noritoshi Minami ◽  
Michio Murase ◽  
Akio Tomiyama

In this paper, results of experiments and numerical simulations for counter-current flow in a pressurized water reactor hot leg under reflux cooling are summarized. In the experiments, we used two types of small scale PWR hot legs. One was a 1/5th scale rectangular duct, and the other was a 1/15th scale circular pipe. Air and water were used for gas and liquid phases. The air flow rate and the supplied water flow rate were varied to observe flow pattern and measure the counter-current flow limitation (CCFL) characteristics. Flow patterns in the elbow and the inclined section were strongly affected by those in the horizontal section. In the 1/15th scale circular pipe experiments, CCFL characteristics obtained by increasing the air flow rate differed from those obtained by decreasing it. CCFL characteristics corresponded to the flow pattern transition. In the numerical simulations, we used a three-dimensional two-fluid model to evaluate the capability of predicting counter-current flow in the hot leg. Good agreements between measured and predicted flow patterns and CCFL characteristics were obtained by using an appropriate set of correlations for interfacial friction coefficient. We also carried out simulations of actual hot leg conditions to examine the effects of fluid properties and size. Predicted flow patterns and CCFL characteristics were close to those of scale model calculations. We concluded the combination of calculation model and interfacial friction coefficients used in this study can predict the counter-current flow in a hot leg.