Phase Distribution of Slug-Annular Flow at a Horizontal Miniature T-Junction

Author(s):  
Shuangfeng Wang ◽  
Kui He ◽  
Jianzhen Huang

In this paper, the behavior of nitrogen-water two-phase flow at a horizontal miniature T-junction with main and side branch of 500 μm diameter was studied. When the inlet flow pattern is slug-annular, the impact of upstream gas and liquid superficial velocity on phase distribution of two-phase flow in the miniature T-junction were investigated in detail. It is found that increasing liquid superficial velocity slightly increase the maldistribution at this work scope. Gas superficial velocity has complex impact on the maldistribution due to different proportion of sub-patterns, and pressure has no impact on phase distribution.

2013 ◽  
Vol 746 ◽  
pp. 575-580
Author(s):  
Xue Min Liu ◽  
Zhou Hang Li ◽  
Yu Xin Wu ◽  
Jun Fu Lu

Aiming at the diameter range of boiler water wall tubes in practical engineering application, the air-water two phase flow pattern in horizontal tube was experimentally investigated in tubes with different inner diameters of 20mm and 8 mm under atmosphere condition. The stratified flow, wave flow, plug flow, slug flow, annular flow, bubbly flow and mist flow were observed in the tubes. Most of the experimental points agree well with the Baker flow pattern map when they appear in the map. With the experimental results, the range lines between the flow patterns were suggested for the tube of 20mm in inner diameter as well as 8mm. As the water superficial velocity increases, the annular flow transforms into mist flow at a decreasing air superficial velocity. The two phase flow patterns transition line is similar in tendency for different tubes. The slug flow transforms into annular flow at an increasing air superficial velocity as tube diameter decreases. The stratified flow transforms into slug flow at an increasing water superficial velocity as tube diameter decreases. The transition line between plug flow and slug flow is independent of tube diameter.


1992 ◽  
Vol 114 (1) ◽  
pp. 14-30 ◽  
Author(s):  
E. F. Caetano ◽  
O. Shoham ◽  
J. P. Brill

Mechanistic models have been developed for each of the existing two-phase flow patterns in an annulus, namely bubble flow, dispersed bubble flow, slug flow, and annular flow. These models are based on two-phase flow physical phenomena and incorporate annulus characteristics such as casing and tubing diameters and degree of eccentricity. The models also apply the new predictive means for friction factor and Taylor bubble rise velocity presented in Part I. Given a set of flow conditions, the existing flow pattern in the system can be predicted. The developed models are applied next for predicting the flow behavior, including the average volumetric liquid holdup and the average total pressure gradient for the existing flow pattern. In general, good agreement was observed between the experimental data and model predictions.


1992 ◽  
Vol 58 (555) ◽  
pp. 3286-3291 ◽  
Author(s):  
Terushige FUJII ◽  
Takeshi NAKAZAWA ◽  
Hiroyuki YAMADA ◽  
Osamu MURAGISHI ◽  
Nobuyuki TAKENAKA ◽  
...  

2019 ◽  
Vol 20 (5) ◽  
pp. 507 ◽  
Author(s):  
Lijun Deng ◽  
Jian Zhang ◽  
Guannan Hao ◽  
Jing Liu

To study factors affecting the formation and conversion of two-phase flow pattern as well as the heat transfer of piston cooling gallery, a transient visual target test bench was set up to research the oscillatory flow characteristics in the cooling gallery under idle condition of the engine. The computational fluid dynamics (CFD) was employed while dynamic mesh technology, SST k–ω turbulence model and volume of fluid (VOF) two-phase flow model were applied to simulate the flow process of piston cooling gallery so as to predict the distribution pattern of two-phase flow. Simulation results were in good agreement with that experimentally obtained. It was observed that in the reciprocating movement of the piston, the action of two-phase flow oscillation was severe, forming some unstable wave flows and slug flows. Results show that under the same pipe diameter, the increase of fluid viscosity results in the decrease of amplitude and the increase of the liquid slugs number as well as the enhancement on heat transfer effect. In addition, it was revealed that injection pressure has little effect on the two-phase flow pattern. However, when the pressure is reduced, the change of the liquid phase is weakened and the locations of flow pattern transition move towards to the behind, thus the impact on the heat transfer is also faint.


Author(s):  
Claudi Marti´n-Callizo ◽  
Bjo¨rn Palm ◽  
Wahib Owhaib ◽  
Rashid Ali

The present work reports on flow boiling visualization of refrigerant R-134a in a vertical circular channel with internal diameter of 1.33 mm and 235 mm in heated length. Quartz tube with a homogeneous ITO-coating is used allowing heating and simultaneous visualization. Flow patterns have been observed along the heated length with the aid of a digital camera with close-up lenses. From the flow boiling visualization, seven distinct two-phase flow patterns have been observed: Isolated bubbly flow, confined bubbly flow, slug flow, churn flow, slug-annular flow, annular flow, and mist flow. Two-phase flow pattern observations are presented in the form of flow pattern maps. Finally, the experimental flow pattern map is compared to models developed for conventional sizes as well as to a microscale map for air-water mixtures available in the literature, showing a large discrepancy.


Author(s):  
Bai Bofeng ◽  
Liu Maolong ◽  
Su Wang ◽  
Zhang Xiaojie

An experimental study was conducted on the air-water two-phase flow patterns in the bed of rectangular cross sections containing spheres of regular distribution. Three kinds of glass spheres with different diameters (3 mm, 6 mm, and 8 mm) were used for the establishment of the test section. By means of visual observations of the two-phase flow through the test section, it was discovered that five different flow patterns occurred within the experimental parameter ranges, namely, bubbly flow, bubbly-slug flow, slug flow, slug-annular flow, and annular flow. A correlation for the bubble and slug diameter in the packed beds was proposed, which was an extended expression of the Tung/Dhir model, Jamialahmadi’s model, and Schmidt’s model. Three correlations were proposed to calculate the void friction of the flow pattern transition in bubble flow, slug flow, and annular flow based on the bubble model in the pore region. The experimental result showed that the modified Tung and Dhir model of the flow pattern transition was in better agreement with the experimental data compared with Tung and Dhir’s model.


2010 ◽  
Vol 132 (3) ◽  
Author(s):  
Claudi Martín-Callizo ◽  
Björn Palm ◽  
Wahib Owhaib ◽  
Rashid Ali

The present work reports on flow boiling visualization of refrigerant R-134a in a vertical circular channel with an internal diameter of 1.33 mm and 235 mm in heated length. A quartz tube with a homogeneous Indium Tin Oxide coating is used to allow heating and simultaneous visualization. Flow patterns have been observed along the heated length with the aid of high-speed complementary metal oxide semiconductor (CMOS) digital camera. From the flow boiling visualization, seven distinct two-phase flow patterns have been observed: isolated bubbly flow, confined bubbly flow, slug flow, churn flow, slug-annular flow, annular flow, and mist flow. Two-phase flow pattern observations are presented in the form of flow pattern maps. The effects of the saturation temperature and the inlet subcooling degree on the two-phase flow pattern transitions are elucidated. Finally, the experimental flow pattern map is compared with models developed for conventional sizes as well as to a microscale map for air-water mixtures available in literature, showing a large discrepancy.