Effects of Protrusions on Conjugate Heat Transfer in a Microtube or Microchannel

Author(s):  
Muhammad M. Rahman ◽  
Phaninder Injeti

Effects of protrusions on heat transfer in a microtube and in a two-dimensional microchannel of finite wall thickness were investigated for various shapes and sizes of the protrusion. Calculations were done for incompressible flow of a Newtonian fluid with developing momentum and thermal boundary layers under uniform and discrete heating conditions. It was found that the local Nusselt number near the protrusions changes significantly with the variations of Reynolds number, height, width, and distance between protrusions, and the distribution of discrete heat sources. The results presented in the paper demonstrate that protrusions can be used advantageously for the enhancement of local heat transfer whereas the global performance may be enhanced or diminished based on the tube geometry.

Author(s):  
Jorge L. Rosales ◽  
Victor A. Chiriac

The unsteady laminar flow and heat transfer characteristics for a pair of confined impinging air jets centered in a channel were studied numerically. The time-averaged heat transfer coefficient for a pair of heat sources centered in the channel and aligned with the jets was determined as well as the oscillating jet frequency for the unsteady cases. The present study continues the authors’ previous investigation, which emphasized how single confined jets will remain steady at Reynolds numbers that make side-by-side jets highly unsteady. The nature of this unsteadiness depends on the proximity of the jet inlets, the channel dimensions and the jet Reynolds number. The jet unsteadiness causes the stagnation point locations to sweep back and forth over the impingement region, and the jets “wash” a larger surface area on the target wall. The results indicate that the dual jets become unsteady between a Reynolds number of 200 and 300. Also, in the range of Reynolds numbers studied, a fixed stagnation “bubble” was formed on the target wall between the two jets, which reduced the heat transfer removal from that region, leading in fact to a quasi-independence of the local heat transfer on flow conditions. The stagnant region contains slow moving warm air that forces the cool impinging air jets to flow to the sides of this target wall area. The oscillating frequency of the flow increases with Reynolds number for the unsteady cases. Also, the time-averaged heat transfer coefficient on the heat sources rises as the Reynolds number increases for the steady cases but there is a slight decrease when it transitions to unsteady flow, indicating again that the stagnation “bubble” occurring between the two heat sources affects the local heat transfer.


1993 ◽  
Vol 115 (3) ◽  
pp. 560-567 ◽  
Author(s):  
N. Zhang ◽  
J. Chiou ◽  
S. Fann ◽  
W.-J. Yang

Experiments are performed to determine the local heat transfer performance in a rotating serpentine passage with rib-roughened surfaces. The ribs are placed on the trailing and leading walls in a corresponding posited arrangement with an angle of attack of 90 deg. The rib height-to-hydraulic diameter ratio, e/Dh, is 0.0787 and the rib pitch-to-height ratio, s/e, is 11. The throughflow Reynolds number is varied, typically at 23,000, 47,000, and 70,000 in the passage both at rest and in rotation. In the rotation cases, the rotation number is varied from 0.023 to 0.0594. Results for the rib-roughened serpentine passages are compared with those of smooth ones in the literature. Comparison is also made on results for the rib-roughened passages between the stationary and rotating cases. It is disclosed that a significant enhancement is achieved in the heat transfer in both the stationary and rotating cases resulting from an installation of the ribs. Both the rotation and Rayleigh numbers play important roles in the heat transfer performance on both the trailing and leading walls. Although the Reynolds number strongly influences the Nusselt numbers in the rib-roughened passage of both the stationary and rotating cases, Nuo and Nu, respectively, it has little effect on their ratio Nu/Nuo.


2000 ◽  
Author(s):  
M. Greiner ◽  
P. F. Fischer ◽  
H. M. Tufo

Abstract Two-dimensional Navier-Stokes simulations of heat and momentum transport in an intermittently grooved passage are performed using the spectral element technique for the Reynolds number range 600 ≤ Re ≤ 1800. The computational domain has seven contiguous transverse grooves cut symmetrically into opposite walls, followed by a flat section with the same length. Periodic inflow/outflow boundary conditions are employed. The development and decay of unsteady flow is observed in the grooved and flat sections, respectively. The axial variation of the unsteady component of velocity is compared to the local heat transfer, shear stress and pressure gradient. The results suggest that intermittently grooved passages may offer even higher heat transfer for a given pumping power than the levels observed in fully grooved passages.


2001 ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Deborah A. Kaminski

Abstract Measurements of the local heat transfer distribution on smooth and roughened surfaces under an array of angled impinging jets are presented. The test rig is designed to simulate impingement with cross-flow in one direction which is a common method for cooling gas turbine components such as the combustion liner. Jet angle is varied between 30, 60, and 90 degrees as measured from the impingement surface, which is either smooth or randomly roughened. Liquid crystal video thermography is used to capture surface temperature data at five different jet Reynolds numbers ranging between 15,000 and 35,000. The effect of jet angle, Reynolds number, gap, and surface roughness on heat transfer efficiency and pressure loss is determined along with the various interactions among these parameters. Peak heat transfer coefficients for the range of Reynolds number from 15,000 to 35,000 are highest for orthogonal jets impinging on roughened surface; peak Nu values for this configuration ranged from 88 to 165 depending on Reynolds number. The ratio of peak to average Nu is lowest for 30-degree jets impinging on roughened surfaces. It is often desirable to minimize this ratio in order to decrease thermal gradients, which could lead to thermal fatigue. High thermal stress can significantly reduce the useful life of engineering components and machinery. Peak heat transfer coefficients decay in the cross-flow direction by close to 24% over a dimensionless length of 20. The decrease of spanwise average Nu in the crossflow direction is lowest for the case of 30-degree jets impinging on a roughened surface where the decrease was less than 3%. The decrease is greatest for 30-degree jet impingement on a smooth surface where the stagnation point Nu decreased by more than 23% for some Reynolds numbers.


2003 ◽  
Vol 125 (3) ◽  
pp. 362-368 ◽  
Author(s):  
Seong-Yeon Yoo ◽  
Jong-Hark Park ◽  
Min-Ho Chung

When heat is released by forced convection from electronic modules in a narrow printed circuit board channel, complex flow phenomena—such as stagnation and acceleration on the front surface, separation and reattachment on the top surface, wake or cavity flow near the rear surface—affect the heat transfer characteristics. The purpose of this study is to investigate how these flow conditions influence the local heat transfer from electronic modules. Experiments are performed on a three-dimensional array of hexahedral elements as well as on a two-dimensional array of rectangular elements. Naphthalene sublimation technique is employed to measure three-dimensional local mass transfer, and the mass transfer data are converted to their counterparts of the heat transfer process using the analogy equation between heat and mass transfer. Module location and streamwise module spacing are varied, and the effect of vortex generators on heat transfer enhancement is also examined. Dramatic change of local heat transfer coefficients is found on each surface of the module, and three-dimensional modules have a little higher heat transfer value than two-dimensional modules because of bypass flow. Longitudinal vortices formed by vortex generator enhance the mixing of fluids and thereby heat transfer, and the rectangular wing type vortex generator is found to be more effective than the delta wing type vortex generator.


Author(s):  
Xing Yang ◽  
Zhao Liu ◽  
Zhenping Feng

Detailed heat transfer distributions are numerically investigated on a multiple jet impingement target surface with staggered arrays of spherical dimples where coolant can be extracted through film holes for external film cooling. The three dimensional Reynolds-averaged Navier-Stokes analysis with SST k-ω turbulence model is conducted at jet Reynolds number from 15,000 to 35,000. The separation distance between the jet plate and the target surface varies from 3 to 5 jet diameters and two jet-induced crossflow schemes are included to be referred as large and small crossflow at one and two opposite exit openings correspondingly. Flow and heat transfer results for the dimpled target plate with three suction ratios of 2.5%, 5.0% and 12.0% are compared with those on dimpled surfaces without film holes. The results indicate the presence of film holes could alter the local heat transfer distributions, especially near the channel outlets where the crossflow level is the highest. The heat transfer enhancements by applying film holes to the dimpled surfaces is improved to different degrees at various suction ratios, and the enhancements depend on the coupling effect of impingement and channel flow, which is relevant to jet Reynolds number, jet-to-plate spacing and crossflow scheme.


2005 ◽  
Vol 2005 (3) ◽  
pp. 211-220 ◽  
Author(s):  
Dieter Bohn ◽  
Jing Ren ◽  
Karsten Kusterer

For the determination of the film-cooling heat transfer, the design of a turbine blade relies on the conventional determination of the adiabatic film-cooling effectiveness and heat transfer conditions for test configurations. Thus, additional influences by the interaction of fluid flow and heat transfer and influences by additional convective heat transfer cannot be taken into account with sufficient accuracy. Within this paper, calculations of a film-cooled duct wall and a film-cooled real blade with application of the adiabatic and a conjugate heat transfer condition have been performed for different configurations. It can be shown that the application of the conjugate calculation method comprises the influence of heat transfer within the cooling film. The local heat transfer rate varies significantly depending on the local position.


1972 ◽  
Vol 94 (1) ◽  
pp. 7-14 ◽  
Author(s):  
L. B. Newman ◽  
E. M. Sparrow ◽  
E. R. G. Eckert

Experiments involving both heat-transfer and turbulence-field measurements were performed to determine the influence of free-stream turbulence on the local heat transfer from a sphere situated in a forced-convection airflow. The research was facilitated by a miniature heat-flux sensor which could be positioned at any circumferential location on the equator of the sphere. Turbulence grids were employed to generate free-stream turbulence with intensities of up to 9.4 percent. The Reynolds-number range of the experiments was from 20,000 to 62,000. The results indicate that the local heat flux in the forward region of the sphere is uninfluenced by free-stream turbulence levels of up to about 5 percent. For higher turbulence levels, the heat-flux increases with the turbulence intensity, the greatest heat-flux augmentation found here being about 15 percent. Furthermore, at the higher turbulence intensities, there appears to be a departure from the half-power Reynolds-number dependence of the stagnation-point Nusselt number. Turbulent separation occurred at Reynolds numbers of 42,000 and 62,000 for a turbulence level of 9.4 percent, these values being well below the transition Reynolds number of 2 × 105 for a sphere situated in a low-turbulence flow.


Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Jae Y. Um ◽  
Ching-Pang Lee

This report describes the detailed experimental study to characterize the local heat transfer coefficient distribution over the internal cooling passages of a simplified generic airfoil. The airfoil is manufactured through additive manufacturing based on actual geometry and dimensions (1X scale model) of row one airfoil, applicable in large gas turbine system. At the mainbody section, the serpentine channel consists of three passages without any surface features or vortex generators. Both the leading edge and trailing edge sections are subjected to direct impingement. The trailing edge section is divided into three chambers, separated by two rows of blockages. This study employs the well-documented transient liquid crystal technique, where the local heat transfer coefficient on both pressure and suction sides is deduced. The experiments were performed at varying Reynolds number, ranging from approximately 31,000–63,000. The heat transfer distribution on the pressure side and suction side is largely comparable in the first and third pass, except for the second pass. Highest heat transfer occurs at the trailing edge region, which is ultimately dominated by impingement due to the presence of three rows of blockages. A cursory numerical calculation is performed using commercially available software, ANSYS CFX to obtain detailed flow field distribution within the airfoil, which explains the heat transfer behavior at each passage. The flow parameter results revealed that the pressure ratio is strongly proportional with increasing Reynolds number.