Characterization of Thermal Properties and Heat Transfer Behavior of Microencapsulated Phase Change Material Slurry and Multiwall Carbon Nanotubes in Aqueous Suspension

Author(s):  
Jorge L. Alvarado ◽  
Charles Marsh ◽  
Curt Thies ◽  
Guillermo Soriano ◽  
Paritosh Garg

In the last decade, microencapsulated phase change material (MPCM) slurries have been proposed and studied as novel coolants for heat transfer applications. Such applications include electronics cooling, and secondary coolants in air conditioning systems among others. Experiments have shown that MPCM’s increase the overall thermal capacity of thermal systems by taking advantage of the phase change material’s latent heat of fusion. However, research has also shown that the overall heat transfer coefficient is diminished due to a reduction in the effective thermal conductivity and increased viscosity of the slurry. For this reason, there is an urgent need to modify the content of microcapsules containing phase change material to increase their effective thermal conductivity and the overall heat transport process. Our solution consists of increasing the thermal conductivity of MPCM by adding carbon nanotubes to the shell and core of the microcapsules. Carbon nanotubes have shown to increase the thermal conductivity of liquids by 40% or more in recent experiments. In this paper, MPCM slurry containing octadecane as phase change material and multi-wall carbon nanotubes (MWCNTs) embedded in the capsule material and core are compared with pure water as heat transfer fluid. Thermal and physical properties of MPCM slurry containing carbon nanotubes were determined using a differential scanning calorimeter and concentric viscometer, respectively. Experimental convective heat transfer coefficient data for MWCNT aqueous suspensions under laminar flow and constant heat flux were determined using a bench-top heat transfer loop. Experimental heat transfer results are presented.

2019 ◽  
Vol 111 ◽  
pp. 01001
Author(s):  
Hansol Lim ◽  
Hye-Jin Cho ◽  
Seong-Yong Cheon ◽  
Soo-Jin Lee ◽  
Jae-Weon Jeong

A phase change material based radiant cooling panel with thermoelectric module (PCM-TERCP) is proposed in this study. It consists of two aluminium panels, and phase change materials (PCMs) sandwiched between the two panels. Thermoelectric modules (TEMs) are attached to one of the aluminium panels, and heat sinks are attached to the top side of TEMs. PCM-TERCP is a thermal energy storage concept equipment, in which TEMs freeze the PCM during the night whose melting temperature is 16○C. Therefore, the radiant cooling panel can maintain a surface temperature of 16◦C without the operation of TEM during the day. Furthermore, it is necessary to design the PCM-TERCP in a way that it can maintain the panel surface temperature during the targeted operating time. Therefore, the numerical model was developed using finite difference method to evaluate the thermal behaviour of PCM-TERCP. Experiments were also conducted to validate the performance of the developed model. Using the developed model, the possible operation time was investigated to determine the overall heat transfer coefficient required between radiant cooling panel and TEM. Consequently, the results showed that a overall heat transfer coefficient of 394 W/m2K is required to maintain the surface temperature between 16○C to 18○C for a 3 hours operation.


Author(s):  
Ayushman Singh ◽  
Srikanth Rangarajan ◽  
Leila Choobineh ◽  
Bahgat Sammakia

Abstract This work presents an approach to optimally designing a composite with thermal conductivity enhancers (TCEs) infiltrated with phase change material (PCM) based on figure of merit (FOM) for thermal management of portable electronic devices. The FOM defines the balance between effective thermal conductivity and energy storage capacity. In present study, TCEs are in the form of a honeycomb structure. TCEs are often used in conjunction with PCM to enhance the conductivity of the composite medium. Under constrained composite volume, the higher volume fraction of TCEs improves the effective thermal conductivity of the composite, while it reduces the amount of latent heat storage simultaneously. The present work arrives at the optimal design of composite for electronic cooling by maximizing the FOM to resolve the stated trade-off. In this study, the total volume of the composite and the interfacial heat transfer area between the PCM and TCE are constrained for all design points. A benchmarked two-dimensional direct CFD model was employed to investigate the thermal performance of the PCM and TCE composite. Furthermore, assuming conduction-dominated heat transfer in the composite, a simplified effective numerical model that solves the single energy equation with the effective properties of the PCM and TCE has been developed. The effective thermal conductivity of the composite is obtained by minimizing the error between the transient temperature gradient of direct and simplified model by iteratively varying the effective thermal conductivity. The FOM is maximized to find the optimal volume fraction for the present design.


Buildings ◽  
2019 ◽  
Vol 9 (10) ◽  
pp. 217 ◽  
Author(s):  
Joanna Krasoń ◽  
Przemysław Miąsik ◽  
Lech Lichołai ◽  
Bernardeta Dębska ◽  
Aleksander Starakiewicz

The article presents a comparative analysis carried out using three methods, determining the heat transfer coefficient U for a ceramic product modified with a phase change material (PCM). The purpose of the article is to determine the convergence of the resulting thermal characteristics, obtained using the experimental method, numerical simulation, and standard calculation method according to the requirements of PN-EN ISO 6946. The heat transfer coefficient is one of the basic parameters characterizing the thermal insulation of a building partition. Most often, for the thermal characteristics of the partition, we obtain from the manufacturer the value of the thermal conductivity coefficient λ for individual homogeneous materials or the heat transfer coefficient U for the finished (prefabricated) partition. In the case of a designed composite element modified with a phase change material or other material, it is not possible to obtain direct information on the above parameter. In such a case, one of the methods presented in this article should be used to determine the U factor. The U factor in all analyses was determined in stationary conditions. Research has shown a significant convergence of the resulting value of the heat transfer coefficient obtained by the assumed methods. Thanks to obtaining similar values, it is possible to continue tests of thermal characteristics of partitions by means of numerical simulation, limiting the number of experimental tests (due to the longer test time required) in assumed different partition configurations, in stationary and dynamic conditions.


Author(s):  
Laura Small ◽  
Fatemeh Hassanipour

This study presents numerical simulations of forced convection with parachute-shaped encapsulated phase-change material particles in water, flowing through a square cross-section duct with top and bottom iso-flux surfaces. The system is inspired by the gas exchange process in the alveolar capillaries between the red blood cells (RBC) and the lung tissue. The numerical model was developed for the motion of elongated encapsulated phase change particles along a channel in a particulate flow where particle diameters are comparable with the channel height. Results of the heat transfer enhancement for the parachute-shaped particles are compared with the circular particles. Results reveal that the key role in heat transfer enhancement is the snugness movement of the particles and the parachute-shaped geometry yields small changes in heat transfer coefficient when compared to the circular ones. The effects of various parameters including particle diameter and volume-fraction, as well as fluid speed, on the heat transfer coefficient is investigated and reported in this paper.


2016 ◽  
Vol 138 (7) ◽  
Author(s):  
María A. Izquierdo-Barrientos ◽  
C. Sobrino ◽  
José A. Almendros-Ibáñez

The objective of this work is to model the heat transfer coefficient between an immersed surface and fixed and bubbling fluidized beds of granular phase change material (PCM). The model consists of a two-region model with two different voidages in which steady and transient conduction problems are solved for the fixed and fluidized bed cases, respectively. The model is validated with experimental data obtained under fixed and fluidized conditions for sand, a common material used in fixed and fluidized beds for sensible heat storage, and for a granular PCM with a phase change temperature of approximately 50 °C. The superficial gas velocity is varied to quantify its influence on the convective heat transfer coefficient for both the materials. The model proposed for the PCM properly predicts the experimental results, except for high flow rates, which cause the contact times between the surface and particles to be very small and lead the model to overpredict the results.


1996 ◽  
Vol 24 (2) ◽  
pp. 119-123
Author(s):  
A. Macías-Machín ◽  
V. Henríquez ◽  
A. Lozano

An experiment to calculate the heat transfer coefficient using a phase change material is described. The various tests use a naphthalene ball which changes from solid to gas. The technique is simple and inexpensive, and it is capable of yielding meaningful results. It will be seen that the heat transfer rises with the temperature and air flowrate. Also, students will be encouraged to analyse their own results and to find other variations to this experiment. This will considerably enhance the students' understanding of the processes at work.


Sign in / Sign up

Export Citation Format

Share Document