New line of high voltage high current pulse generators for plasma-based ion implantation

Author(s):  
O. Maulat ◽  
M. Roche ◽  
F. Le Coeur ◽  
O. Lesaint ◽  
Y. Arnal ◽  
...  
2019 ◽  
Vol 40 (12) ◽  
pp. 1965-1968 ◽  
Author(s):  
Chao Liu ◽  
Wanjun Chen ◽  
Ruize Sun ◽  
Yijun Shi ◽  
Qi Zhou ◽  
...  

1992 ◽  
Vol 20 (6) ◽  
pp. 967-972 ◽  
Author(s):  
N.A. Gondarenko ◽  
T.A. Golub ◽  
A.M. Iskoldsky

2008 ◽  
Vol 3 (4) ◽  
pp. 68-73
Author(s):  
Aleksandr V. Akimov ◽  
Petr A. Bak ◽  
Andrey A. Korepanov ◽  
Pavel V. Logachev ◽  
Viktor D. Bochkov ◽  
...  

The circuit of modulator, serving to supply inductive-resistive load in double-pulse mode with currents up to 10 kA and pulse duration of 300 ns, is described. As switching components unheated cathode thyratrons (pseudospark switches) TPI1-10k/50 and TPI5-10k/50 with anode voltage up to 50 kV have been used. The results of tests, confirming possibility of the thyratron reverse dielectric strength recovery within some microseconds after switching of 10 kA forward anode current, are presented.


2014 ◽  
Vol 32 ◽  
pp. 1460333
Author(s):  
A. V. Grishin ◽  
S. L. Glushkov ◽  
B. P. Mironychev ◽  
D. A. Kalashnikov ◽  
A. V. Kozachek ◽  
...  

At RFNC-VNIIEF on the basis of a “Gamma-1” high-current pulsed accelerator there is being developed a four-module “Gamma-4” electrophysical facility. A synchronization system of the "Gamma-4" facility is meant for a simultaneous (with precision not worse than ±3 ns) triggering of high-volt gas-filled trigatron type switches of modules' pulse forming systems (144 items, operating voltage ≤ 1 MV), modules' pre-pulse switches (24 items, ≤ 3 MV) and 8 Marx generators (40 items, ≤ 100 kV). The synchronization system comprises 54 pulse generators, involving 25 generators on the basis of water insulated forming lines with distributed parameters and multi-channel gas-filled switches. On matched cable loads with resistances 0.45 Ohm these generators form voltage pulses with amplitudes 100 kV with durations 25 ns. A jitter of switches of these generators does not exceed ± 2 ns. To raise the amplitude of pulse drivers of pulse forming system switches and pre-pulse switches of modules in the facility synchronization system there are used step-up transformers based on pulsed high-voltage cables.


2016 ◽  
Vol 16 (10) ◽  
pp. 3792-3801 ◽  
Author(s):  
T. Huiskamp ◽  
F. J. C. M. Beckers ◽  
E. J. M. van Heesch ◽  
A. J. M. Pemen