Design of a head mounted optical tracking system for surgical navigation (Conference Presentation)

Author(s):  
Ryan Deorajh ◽  
Peter Morcos ◽  
Jamil Jivraj ◽  
Joel M. Ramjist ◽  
Victor X. Yang
Author(s):  
Roeland Eppenga ◽  
Koert Kuhlmann ◽  
Theo Ruers ◽  
Jasper Nijkamp

Abstract Purpose Surgical navigation systems are generally only applied for targets in rigid areas. For non-rigid areas, real-time tumor tracking can be included to compensate for anatomical changes. The only clinically cleared system using a wireless electromagnetic tracking technique is the Calypso® System (Varian Medical Systems Inc., USA), designed for radiotherapy. It is limited to tracking maximally three wireless 5-degrees-of-freedom (DOF) transponders, all used for tumor tracking. For surgical navigation, a surgical tool has to be tracked as well. In this study, we evaluated whether accurate 6DOF tumor tracking is possible using only two 5DOF transponders, leaving one transponder to track a tool. Methods Two methods were defined to derive 6DOF information out of two 5DOF transponders. The first method uses the vector information of both transponders (TTV), and the second method combines the vector information of one transponder with the distance vector between the transponders (OTV). The accuracy of tracking a rotating object was assessed for each method mimicking clinically relevant and worst-case configurations. Accuracy was compared to using all three transponders to derive 6DOF (Default method). An optical tracking system was used as a reference for accuracy. Results The TTV method performed best and was as accurate as the Default method for almost all transponder configurations (median errors < 0.5°, 95% confidence interval < 3°). Only when the angle between the transponders was less than 2°, the TTV method was inaccurate and the OTV method may be preferred. The accuracy of both methods was independent of the angle of rotation, and only the OTV method was sensitive to the plane of rotation. Conclusion These results indicate that accurate 6DOF tumor tracking is possible using only two 5DOF transponders. This encourages further development of a wireless EM surgical navigation approach using a readily available clinical system.


2013 ◽  
Vol 31 (2) ◽  
pp. 223-231 ◽  
Author(s):  
Rongqian Yang ◽  
Zhigang Wang ◽  
Sujuan Liu ◽  
Xiaoming Wu

2021 ◽  
Vol 11 (9) ◽  
pp. 3947
Author(s):  
Marco Farronato ◽  
Gianluca M. Tartaglia ◽  
Cinzia Maspero ◽  
Luigi M. Gallo ◽  
Vera Colombo

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra- and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2528
Author(s):  
Songlin Bi ◽  
Yonggang Gu ◽  
Jiaqi Zou ◽  
Lianpo Wang ◽  
Chao Zhai ◽  
...  

A high precision optical tracking system (OTS) based on near infrared (NIR) trinocular stereo vision (TSV) is presented in this paper. Compared with the traditional OTS on the basis of binocular stereo vision (BSV), hardware and software are improved. In the hardware aspect, a NIR TSV platform is built, and a new active tool is designed. Imaging markers of the tool are uniform and complete with large measurement angle (>60°). In the software aspect, the deployment of extra camera brings high computational complexity. To reduce the computational burden, a fast nearest neighbor feature point extraction algorithm (FNNF) is proposed. The proposed method increases the speed of feature points extraction by hundreds of times over the traditional pixel-by-pixel searching method. The modified NIR multi-camera calibration method and 3D reconstruction algorithm further improve the tracking accuracy. Experimental results show that the calibration accuracy of the NIR camera can reach 0.02%, positioning accuracy of markers can reach 0.0240 mm, and dynamic tracking accuracy can reach 0.0938 mm. OTS can be adopted in high-precision dynamic tracking.


2020 ◽  
Vol 31 (01) ◽  
pp. 040-049 ◽  
Author(s):  
Robert W. Koch ◽  
Hasan Saleh ◽  
Paula Folkeard ◽  
Sheila Moodie ◽  
Conner Janeteas ◽  
...  

AbstractProbe-tube placement is a necessary step in hearing aid verification which needs ample hands-on experience and confidence before performing in clinic. To improve the methods of training in probe-tube placement, a manikin-based training simulator was developed consisting of a 3D-printed head, a flexible silicone ear, and a mounted optical tracking system. The system is designed to provide feedback to the user on the depth and orientation of the probe tube, and the time required to finish the task. Although a previous validation study was performed to determine its realism and teachability with experts, further validation is required before implementation into educational settings.This study aimed to examine the skill transference of a newly updated probe-tube placement training simulator to determine if skills learned on this simulator successfully translate to clinical scenarios.All participants underwent a pretest in which they were evaluated while performing a probe-tube placement and real-ear-to-coupler difference (RECD) measurement on a volunteer. Participants were randomized into one of two groups: the simulator group or the control group. During a two-week training period, all participants practiced their probe-tube placement according to their randomly assigned group. After two weeks, each participant completed a probe-tube placement on the same volunteer as a posttest scenario.Twenty-five novice graduate-level student clinicians.Participants completed a self-efficacy questionnaire and an expert observer completed a questionnaire evaluating each participant’s performance during the pre- and posttest sessions. RECD measurements were taken after placing the probe tube and foam tip in the volunteer’s ear. Questionnaire results were analyzed through nonparametric t-tests and analysis of variance, whereas RECD results were analyzed using a nonlinear mixed model method.Results suggested students in the simulator group were less likely to contact the tympanic membrane when placing a probe tube, appeared more confident, and had better use of the occluding foam tip, resulting in more improved RECD measurements.The improved outcomes for trainees in the simulator group suggest that supplementing traditional training with the simulator provides useful benefits for the trainees, thereby encouraging its usage and implementation in educational settings.