The low-order wavefront control system for the PICTURE-C mission: high-speed image acquisition and processing

Author(s):  
Kuravi Hewawasam ◽  
Christopher B. Mendillo ◽  
Glenn A. Howe ◽  
Supriya Chakrabarti ◽  
Timothy A. Cook ◽  
...  
Author(s):  
Glenn A. Howe ◽  
Christopher B. Mendillo ◽  
Kuravi Hewawasam ◽  
Supriya Chakrabarti ◽  
Timothy A. Cook ◽  
...  

2014 ◽  
Vol 513-517 ◽  
pp. 1192-1196
Author(s):  
Ju Bao Qu ◽  
Shu Juan Wang

Testing for a variety of different industrial objects, this paper designed a multi on-line machine vision based on intelligent quality control system solutions. Microvision based on the company introduced the MV-8002 image acquisition card and the MV-VS1394 camera visual inspection of industrial software and hardware structure and the working principle of a high-speed online learning model of intelligent foreign recognition, it described the image acquisition card and the camera with the application and the software development. by the applications case, and the further evidence of the reliability of this system.


Author(s):  
Brian Cross

A relatively new entry, in the field of microscopy, is the Scanning X-Ray Fluorescence Microscope (SXRFM). Using this type of instrument (e.g. Kevex Omicron X-ray Microprobe), one can obtain multiple elemental x-ray images, from the analysis of materials which show heterogeneity. The SXRFM obtains images by collimating an x-ray beam (e.g. 100 μm diameter), and then scanning the sample with a high-speed x-y stage. To speed up the image acquisition, data is acquired "on-the-fly" by slew-scanning the stage along the x-axis, like a TV or SEM scan. To reduce the overhead from "fly-back," the images can be acquired by bi-directional scanning of the x-axis. This results in very little overhead with the re-positioning of the sample stage. The image acquisition rate is dominated by the x-ray acquisition rate. Therefore, the total x-ray image acquisition rate, using the SXRFM, is very comparable to an SEM. Although the x-ray spatial resolution of the SXRFM is worse than an SEM (say 100 vs. 2 μm), there are several other advantages.


2012 ◽  
Vol 132 (3) ◽  
pp. 347-356 ◽  
Author(s):  
Yuta Nabata ◽  
Tatsuya Nakazaki ◽  
Tokoku Ogata ◽  
Kiyoshi Ohishi ◽  
Toshimasa Miyazaki ◽  
...  

2015 ◽  
Vol 46 (3) ◽  
pp. 259-287
Author(s):  
Viktor Andreevich Anikin ◽  
Oleg Vladimirovich Animitsa ◽  
Vladimir Mikhailovich Kuvshinov ◽  
Veniamin Aleksandrovich Leontiev
Keyword(s):  

2020 ◽  
Vol 38 (8A) ◽  
pp. 1187-1199
Author(s):  
Qaed M. Ali ◽  
Mohammed M. Ezzalden

BLDC motors are characterized by electronic commutation, which is performed by using an electric three-phase inverter. The direct control system of the BLDC motor consists of double loops; including the inner-loop for current regulating and outer-loop for speed control. The operation of the current controller requires feedback of motor currents; the conventional current controller uses two current sensors on the ac side of the inverter to measure the currents of two phases, while the third current would be accordingly calculated. These two sensors should have the same characteristics, to achieve balanced current measurements. It should be noted that the sensitivity of these sensors changes with time. In the case of one sensor fails, both of them must be replaced. To overcome this problem, it is preferable to use one sensor instead of two. The proposed control system is based on a deadbeat predictive controller, which is used to regulate the DC current of the BLDC motor. Such a controller can be considered as digital controller mode, which has fast response, high precision and can be easily implemented with microprocessor. The proposed control system has been simulated using Matlab software, and the system is tested at a different operating condition such as low speed and high speed.


2010 ◽  
Vol 7 ◽  
pp. 109-117
Author(s):  
O.V. Darintsev ◽  
A.B. Migranov ◽  
B.S. Yudintsev

The article deals with the development of a high-speed sensor system for a mobile robot, used in conjunction with an intelligent method of planning trajectories in conditions of high dynamism of the working space.


2021 ◽  
Vol 11 (7) ◽  
pp. 3122
Author(s):  
Srujana Neelam ◽  
Audrey Lee ◽  
Michael A. Lane ◽  
Ceasar Udave ◽  
Howard G. Levine ◽  
...  

Since opportunities for spaceflight experiments are scarce, ground-based microgravity simulation devices (MSDs) offer accessible and economical alternatives for gravitational biology studies. Among the MSDs, the random positioning machine (RPM) provides simulated microgravity conditions on the ground by randomizing rotating biological samples in two axes to distribute the Earth’s gravity vector in all directions over time. Real-time microscopy and image acquisition during microgravity simulation are of particular interest to enable the study of how basic cell functions, such as division, migration, and proliferation, progress under altered gravity conditions. However, these capabilities have been difficult to implement due to the constantly moving frames of the RPM as well as mechanical noise. Therefore, we developed an image acquisition module that can be mounted on an RPM to capture live images over time while the specimen is in the simulated microgravity (SMG) environment. This module integrates a digital microscope with a magnification range of 20× to 700×, a high-speed data transmission adaptor for the wireless streaming of time-lapse images, and a backlight illuminator to view the sample under brightfield and darkfield modes. With this module, we successfully demonstrated the real-time imaging of human cells cultured on an RPM in brightfield, lasting up to 80 h, and also visualized them in green fluorescent channel. This module was successful in monitoring cell morphology and in quantifying the rate of cell division, cell migration, and wound healing in SMG. It can be easily modified to study the response of other biological specimens to SMG.


Sign in / Sign up

Export Citation Format

Share Document