Micro-Raman spectroscopy for identification and classification of UTI bacteria

Author(s):  
Kiran Chawla ◽  
Mahendra Acharya ◽  
Santhosh Chidangil ◽  
Aseefhali Bankapur ◽  
Yogesha M
2013 ◽  
Vol 44 (9) ◽  
pp. 1299-1305 ◽  
Author(s):  
Giovanna Piantanida ◽  
Eva Menart ◽  
Marina Bicchieri ◽  
Matija Strlič

2012 ◽  
Vol 43 (11) ◽  
pp. 1811-1816 ◽  
Author(s):  
Maria Cruz Zuluaga ◽  
Ainhoa Alonso‐Olazabal ◽  
Maitane Olivares ◽  
Luis Ortega ◽  
Xabier Murelaga ◽  
...  

1998 ◽  
Author(s):  
I. De Wolf ◽  
G. Groeseneken ◽  
H.E. Maes ◽  
M. Bolt ◽  
K. Barla ◽  
...  

Abstract It is shown, using micro-Raman spectroscopy, that Shallow Trench Isolation introduces high stresses in the active area of silicon devices when wet oxidation steps are used. These stresses result in defect formation in the active area, leading to high diode leakage currents. The stress levels are highest near the outer edges of line structures and at square structures. They also increase with decreasing active area dimensions.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Simon D. Dryden ◽  
Salzitsa Anastasova ◽  
Giovanni Satta ◽  
Alex J. Thompson ◽  
Daniel R. Leff ◽  
...  

AbstractUrinary tract infection is one of the most common bacterial infections leading to increased morbidity, mortality and societal costs. Current diagnostics exacerbate this problem due to an inability to provide timely pathogen identification. Surface enhanced Raman spectroscopy (SERS) has the potential to overcome these issues by providing immediate bacterial classification. To date, achieving accurate classification has required technically complicated processes to capture pathogens, which has precluded the integration of SERS into rapid diagnostics. This work demonstrates that gold-coated membrane filters capture and aggregate bacteria, separating them from urine, while also providing Raman signal enhancement. An optimal gold coating thickness of 50 nm was demonstrated, and the diagnostic performance of the SERS-active filters was assessed using phantom urine infection samples at clinically relevant concentrations (105 CFU/ml). Infected and uninfected (control) samples were identified with an accuracy of 91.1%. Amongst infected samples only, classification of three bacteria (Escherichia coli, Enterococcus faecalis, Klebsiella pneumoniae) was achieved at a rate of 91.6%.


2021 ◽  
Vol 37 ◽  
pp. 102910
Author(s):  
Jhih-Huei Liu ◽  
Weiying Ke ◽  
Ming-chorng Hwang ◽  
Kuang Yu Chen

Author(s):  
D. J. Bailey ◽  
M. C. Stennett ◽  
J. Heo ◽  
N. C. Hyatt

AbstractSEM–EDX and Raman spectroscopy analysis of radioactive compounds is often restricted to dedicated instrumentation, within radiological working areas, to manage the hazard and risk of contamination. Here, we demonstrate application of WetSEM® capsules for containment of technetium powder materials, enabling routine multimodal characterisation with general user instrumentation, outside of a controlled radiological working area. The electron transparent membrane of WetSEM® capsules enables SEM imaging of submicron non-conducting technetium powders and acquisition of Tc Lα X-ray emission, using a low cost desktop SEM–EDX system, as well as acquisition of good quality μ-Raman spectra using a 532 nm laser.


Sign in / Sign up

Export Citation Format

Share Document