leakage currents
Recently Published Documents


TOTAL DOCUMENTS

975
(FIVE YEARS 130)

H-INDEX

38
(FIVE YEARS 4)

2022 ◽  
Vol 1211 (1) ◽  
pp. 012020
Author(s):  
O К Nikolsky ◽  
T M Khalina

Abstract The developments of the AltSTU have been reviewed in the area of creating a new technology for preventing technogenic hazards based on the residual current devices. The residual current devices are intended for protecting people from electric shock in case of contact with conductive parts of the electric appliances and shall facilitate reduction of fire risks caused by a prolonged flow of leakage currents and fault currents resulting from them. The results of creating different modifications of protective trip circuits and their industrial use are provided.


Author(s):  
Yury V. LISAKOV ◽  
Olga V. LAPSHINOVA ◽  
Nikolay M. PUSHKIN ◽  
Viktor P. KONOSHENKO ◽  
Nikolay V. MATVEEV ◽  
...  

The paper presents the results of analysis of electrical measurements performed in the space experiment "Impulse (stage 1)" on the Service module of the ISS RS. This experiment investigated the effects of the interaction of the charged component of the ionosphere to the surface of large KA, which is the ISS. This paper analyses the measurement of quasi-stationary electric field and current leakage, was, respectively, sensors of the vibration type and flat probes from the Complex control electrophysical parameters (CCEP), developed by SPJ MT. To study the dependence of measurements from the ionosphere flow direction to the surface of the ISS RS was installed two sets of sensors with the direction of the angle of "visibility" in the Nadir (towards the Earth) and to "satellite footprint " (against the velocity vector of the ISS). Carried out analysis of common regularities measurements depending on the sun-shadow environment on orbit ISS motions and depending on current geophysical dynamics of the ionosphere. Massive the measurements including more than 170 telemetric sessions were analyzed. More than 11000 hours of measurements current of leakage (or runoff current) and measurements of quasi-stationary electric field with discretization 1s and UT binding to each point were analysed. The data measurements, geophysical and orbital data were collected in an electronic album. It is shown that experimental data correlate with the crossing time of the ISS boundaries known geophysical structures: the noon Meridian, the Main ionospheric failure (MIF), the boundaries diffuse intrusion (BDI), the Equatorial Geomagnetic anomaly (EA). In this regard, despite the specificity of the ISS (the spacecraft super big sizes, the most complex spatial configuration) similar measurements, nevertheless, are quite suitable for monitoring researches of some features of an ionosphere at the level of F2 layer with a temporary scale from 1s and can be used for more detailed study of the geophysical structures and related effects in the ionosphere. In addition, the results obtained can be used for the analysis of disturbances of electromagnetic conditions near the surface of the ISS RS, for monitoring potential and currents of leakage on the surface of the ISS. Keywords: electrophysical measurements, sensors of the vibration type, flat probes, electric field, current leakage, geophysical structure, ionosphere


Author(s):  
G. Yu. Sotnikova ◽  
G. A. Gavrilov ◽  
K. L. Muratikov ◽  
R. S. Passet ◽  
E. P. Smirnova
Keyword(s):  

Author(s):  
А. A.  PLUGIN ◽  
D. А. PLUGIN ◽  
S. V. MIROSHNICHENKO ◽  
O. A. KALININ ◽  
O. P. KRYKUN

Purpose. On the railways of Ukraine in some areas there is an intensive premature exit sleepers due to the formation of defects that can affect the safety of trains and cause significant material losses due to a single replacement of a significant number of sleepers. The purpose of the study is to establish the causes of damage reinforced concrete sleepers on a characteristic section of the railway with their intense premature exit. Methodology. The condition of reinforced concrete sleepers of SB3 type under unlined substrate fastenings on 324-332 km of the pair track of the Odnorobivka-Bukine section of the Southern Railway was studied, where since 2007 their intensive output was observed due to defects. Findings. It is established that for 15 years of operation, as 236.3 million tons were put into operation, about 2.8 % of sleepers were replaced due to defects (44 pieces per 1 km of track). Typical defects (damages), due to which the sleepers were removed from the track, were mainly 13.2 and 13.2 according to the classification of CP-0150 – cracks and fractures of sleepers, including ones with crushing concrete. These defects were preceded by the formation of a network of thin cracks on the visible surfaces of sleepers. 3 sleepers with an initial compressive strength of 68…77 MPa produced by the Korosten Reinforced Concrete Sleeper Plant and the Gnivan Special Reinforced Concrete Plant, removed from the track due to characteristic defects, were selected and investigated. Samples were selected from the sleepers, with the help of which there was determined the final strength of concrete and microscopic examinations, including luminescence flaw detection method, were performed. It was found that the network of cracks in sleepers is spatial, mostly developed mostly beneath their top edge, the least developed above the bottom edge, and causes a decrease in compressive strength of concrete by 47…72 %. It is noted that the destruction of concrete during loading occurred behind these cracks. On the inner surfaces of the cracks there are individual grains of aggregates, which have signs of active silica content, that together with the nature of the cracks may indicate that the cause of their formation is corrosion of concrete from the interaction of cement alkali with reactive aggregates. On the surfaces of the cracks in the lower part of the sleepers leaching products were found, apparently leached by electro migration, which may indicate that corrosion processes were promoted by leakage currents on electrified DC tracks. Originality Thus, in the study area, the main cause of defects, which caused the replacement of the sleepers – was the corrosion of concrete due to the interaction of cement alkali with reactive aggregates, promoted by leakage currents, as well as a small diagram of sleepers and the use of unlined anchor intermediate rail fasteners. Practical value. The results of the study allow to establish the causes of cracks and other damage in reinforced concrete sleepers during operation and, in turn, reduce the losses of fasteners manufacturers and sleepers from defects and complaints, optimize the total cost of track repairs and subsequent track maintenance due to rational purpose of track construction, reduction of damage and replacement of sleepers during track operation.


Author(s):  
Anastasia Svetlova ◽  
Dmitry Kireev ◽  
Guillermo Beltramo ◽  
Dirk Mayer ◽  
Andreas Offenhäusser

Crystals ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1431
Author(s):  
Daniel Hofstetter ◽  
Cynthia Aku-Leh ◽  
Hans Beck ◽  
David P. Bour

An optically activated, enhancement mode heterostructure field effect transistor is proposed and analytically studied. A particular feature of this device is its gate region, which is made of a photovoltaic GaN/AlN-based superlattice detector for a wavelength of 1.55 µm. Since the inter-subband transition in this superlattice does normally not interact with TE-polarized (or vertically incoming) radiation, a metallic second-order diffraction grating on the transistor gate results in a re-orientation of the light into the horizontal direction—thus providing the desired TM-polarization. Upon illumination of this gate, efficient inter-subband absorption lifts electrons from the ground to the first excited quantized state. Due to partial screening of the strong internal polarization fields between GaN quantum wells and AlN barriers, this slightly diagonal transition generates an optical rectification voltage. Added to a constant electrical bias, this optically produced gate voltage leads to a noticeable increase of the transistor’s source-drain current. The magnitude of the bias voltage is chosen to result in maximal transconductance. Since such a phototransistor based on high-bandgap material is a device involving only fast majority carriers, very low dark and leakage currents are expected. The most important advantage of such a device, however, is the expected switching speed and, hence, its predicted use as an optical logic gate for photonic computing. In the absence of a p-n-junction and thus of both a carrier-induced space charge region, and the parasitic capacitances resulting thereof, operation frequencies of appropriately designed, sufficiently small phototransistors reaching 100 GHz are envisaged.


2021 ◽  
Vol 154 (9) ◽  
Author(s):  
Fenfen Wu ◽  
Marbella Quiñonez ◽  
Marino Difranco ◽  
Stephen Cannon

The recurrent attacks of weakness in hypokalemic periodic paralysis (HypoPP) are caused by failure to maintain the resting potential, with paradoxical depolarization in low K+. Remarkably, 24 out of 25 HypoPP mutations are R/X substitutions in S4 segments of voltage-sensing domains of CaV1.1 (70% of cases) or NaV1.4 (10% of cases). Expression studies in oocytes and murine muscle show anomalous gating pore leakage currents (ω-pore) for six of eight CaV1.1-HypoPP mutations, with one exception being the charge-conserving R897K. The proposed consensus pathomechanism, whereby a gating pore leak predisposes to paradoxical depolarization in low K+, is now verified by continuous recording of Vm. Selective measurement of voltage-dependent Ca2+ release, in “healthy appearing” HypoPP fibers, shows only a modest decrease in the Ca2+-dependent peak fluorescence (Oregon green 488/EGTA), and supports the notion that stabilizing Vrest will be sufficient to prevent low-K+–induced loss of force. In our knockin mouse models of HypoPP (CaV1.1-R528H and NaV1.4-R669H), pretreatment with K+-channel openers protects against the loss of force with a 2 mM K+ challenge. Alternatively, gene editing offers the possibility of sustained protection from attacks of weakness, and may prevent the late-onset permanent myopathy. In a proof-of-principle study of cultured myoblasts and in vivo electroporation, we show selective editing of the mutant HypoPP allele, without compromise of the WT allele, using CRISPR/Cas-mediated indel formation to destroy the HypoPP allele or a CRISPR/Cas base editor to correct the missense mutation.


2021 ◽  
Vol 9 ◽  
Author(s):  
Chunhua Fang ◽  
Yuning Tao ◽  
Jianguo Wang ◽  
Can Ding ◽  
Li Huang ◽  
...  

A fundamental parameter of polluted insulator online monitoring is the leakage current, which has already been shown to be well-related to the pollution discharge of insulators. In this article, in an effort to quantitatively reflect the discharge intensity and the discharge status by the leakage current, we carried out an experimental study on artificial pollution discharge of insulators. A high-speed photographic apparatus was utilized to capture the entire process of local arcs on a porcelain insulator surface, including the arc generation, the arc development, and the flashover, for which the associated leakage current of insulators was synchronously digitized. A comparative analysis of the relation between the two-dimensional discharge image and the leakage current waveform in the process of arc generation and development shows that if the arc area on the insulator surface is relatively small and the leakage current passes through zero, the arc might completely become extinct, whereas this phenomena will not occur if the arc area is larger. In addition, the amplitude of the discharge arc area is found to be roughly proportional to the square of leakage current over the range of leakage current amplitude from 0 to 150 mA. Our results can provide an important guidance for judgment of the discharge status and the discharge intensity on insulator surfaces using the leakage current of insulators.


Sign in / Sign up

Export Citation Format

Share Document