High-speed solid state recorder for airborne recce

1996 ◽  
Author(s):  
Wallace G. Fishell ◽  
Kenneth J. Handel ◽  
James M. Rader
Vestnik MEI ◽  
2020 ◽  
Vol 6 (6) ◽  
pp. 82-90
Author(s):  
Dmitriy I. Panfilov ◽  
◽  
Mikhail G. Astashev ◽  
Aleksandr V. Gorchakov ◽  
◽  
...  

The specific features relating to voltage control of power transformers at distribution network transformer substations are considered. An approach to implementing high-speed on-load voltage control of serially produced 10/0.4 kV power transformers by using a solid-state on-load tap changer (SOLTC) is presented. An example of the SOLTC circuit solution on the basis of thyristor switches is given. On-load voltage control algorithms for power transformers equipped with SOLTC that ensure high reliability and high-speed operation are proposed. The SOLTC performance and the operability of the suggested voltage control algorithms were studied by simulation in the Matlab/Simulink environment and by experiments on the SOLTC physical model. The structure and peculiarities of the used simulation Matlab model are described. The SOLTC physical model design and its parameters are presented. The results obtained from the simulating the SOLTC operation on the Matlab model and from the experiments on the SOLTS physical model jointly with a power transformer under different loads and with using different control algorithms are given. An analysis of the experimental study results has shown the soundness of the adopted technical solutions. It has been demonstrated that the use of an SOLTC ensures high-speed voltage control, high efficiency and reliability of its operation, and arcless switching of the power transformer regulating taps without load voltage and current interruption. By using the SOLTC operation algorithms it is possible to perform individual phase voltage regulation in a three-phase 0.4 kV distribution network. The possibility of integrating SOLTC control and diagnostic facilities into the structure of modern digital substations based on the digital interface according to the IEC 61850 standard is noted.


2013 ◽  
Vol 710 ◽  
pp. 269-272
Author(s):  
Guo Ya Xu ◽  
Jun Hua He ◽  
Fan Sen ◽  
Yuan Tao Zhu

Design an all-optical solid-state scanner chip, which can realize high speed light deflection in a very small space, instead of electron beam deflection scan image converter tube and opto-mechanical scanner, cancel the complicated mechanical components, use the all-optical scanning to realize the super fast phenomenon observation. The beam deflection system is based on semiconductor optical waveguide core layer carrier induced refractive index change effect to realize, its development work is mainly divided into semiconductor optical waveguide and saw prisms two parts. And through the experiment, we measured deflection angle of the scanner chip to 1053nm signal light.


2017 ◽  
Vol 10 (28) ◽  
pp. 1-12
Author(s):  
Aykut Zongur ◽  
M. Fatih Talu ◽  
Ali Ozdes ◽  
◽  
◽  
...  

2021 ◽  
Vol 19 (9) ◽  
pp. 093301
Author(s):  
Kohei Suzuki ◽  
Minori Tao ◽  
Yuki Maeda ◽  
Hirotaka Nakayama ◽  
Ren Noguchi ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 934
Author(s):  
Yanwen Wang ◽  
Le Wang ◽  
Sven G. Bilén ◽  
Yan Gao

Due to the working condition of low-voltage cabling from the mining flameproof movable substation to the loads of the mining face being poor, it is easy to cause various external mechanical damages to the cable sheaths. Furthermore, a single-phase earth leakage fault or short-circuit fault can occur when the low-voltage cable sheaths are damaged, and electric sparks caused by these faults can lead to a gas explosion. As the gas detonation time caused by the above faults is usually more than 5 ms, the high-speed interruption solid-state switch which controls the cables must cut off the current within 3 ms. This requires the action time of the solid-state switch to be less than 1 ms, and at the same time, the sampling and calculation time of the relay protection must be less than 2 ms. Based on these problems, this paper proposes the use of a high-speed solid-state circuit breaker (SSCB) topology at the neutral point of transformer, and analyzes the conduction mechanism and shut-off mechanism of the current of the SSCB. It presents an ultra-high-speed algorithm based on pattern recognition of single-phase earth leakage fault protection, and an ultra-high-speed algorithm of short-circuit fault which is based on the rate-of-change of the current. Finally, through computer simulation experiments and semi-physical simulation experiments, the feasibility of the above three technologies is verified to ensure that when a single-phase earth leakage fault or short-circuit fault occurs in the low-voltage cable, the solid-state switch which is installed in the mining flameproof movable substation will cut off the current within 3 ms.


Sign in / Sign up

Export Citation Format

Share Document