SU-FF-J-143: A Feasibility Study of Using O-18 Enriched Water to Develop a Method of In-Vivo Range Verification in Proton Therapy

2009 ◽  
Vol 36 (6Part8) ◽  
pp. 2509-2509 ◽  
Author(s):  
J Cho ◽  
R Schulte ◽  
B Patyal
2018 ◽  
Vol 52 ◽  
pp. 21
Author(s):  
Liheng Tian ◽  
Georgios Dedes ◽  
Guillaume Landry ◽  
Florian Kamp ◽  
Katharina Niepel ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Kristian Smeland Ytre-Hauge ◽  
Kyrre Skjerdal ◽  
John Mattingly ◽  
Ilker Meric

An amendment to this paper has been published and can be accessed via a link at the top of the paper.


Author(s):  
Teresa Rodríguez-González ◽  
Carlos Guerrero ◽  
María del Carmen Jiménez-Ramos ◽  
Jorge Lerendegui-Marco ◽  
María de los Ángeles Millán-Callado ◽  
...  

2020 ◽  
Vol 239 ◽  
pp. 24003
Author(s):  
T. Rodríguez-González ◽  
C. Guerrero ◽  
M.C. Jiménez-Ramos ◽  
P. Dendooven ◽  
J. Lerendegui-Marco ◽  
...  

In-vivo Positron Emission Tomography (PET) range verification relies on the comparison of the measured and estimated activity distributions from β+ emitters induced by the proton beam on the most abundant elements in the human body, right after (looking at the long-lived β+ emitters 11C, 13N and 15O) or during (looking at the short-lived β+ emitters 29P, 12N, 38mK and 10C) the irradiation. The accuracy of the estimated activity distributions is basically that of the underlying cross section data. In this context, the aim of this work is to improve the knowledge of the production yields of β+ emitters of interest in proton therapy. In order to measure the long-lived β+ isotopes, a new method has been developed combining the multi-foil technique with the measurement of the induced activity with a clinical PET scanner. This technique has been tested successfully below 18 MeV at CNA (Spain) and will be used at a clinical beam to obtain data up to 230 MeV. However, such method does not allow measuring the production short-lived isotopes (lower half-life). For this, the proposed method combines a series of targets sandwiched between aluminum foils (acting as both degraders and converters) placed between two LaBr3 detectors that will measure the pairs of 511 keV γ-rays. The first tests will take place at the AGOR facility at KVI-CART, in Groningen.


2017 ◽  
Vol 99 (1) ◽  
pp. 210-218 ◽  
Author(s):  
Yunhe Xie ◽  
El Hassane Bentefour ◽  
Guillaume Janssens ◽  
Julien Smeets ◽  
François Vander Stappen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document