SU-E-T-398: Case Study of Performance Testing Method for An Intensity Modulated Radiation Therapy Treatment Planning System Named RayStation

2013 ◽  
Vol 40 (6Part17) ◽  
pp. 296-296 ◽  
Author(s):  
Q Wu ◽  
X Zhang ◽  
X Yang ◽  
W Yan ◽  
G Li
2019 ◽  
Vol 18 (03) ◽  
pp. 239-245
Author(s):  
Zahra ◽  
Jalil ur Rehman ◽  
H M Noor ul Huda Khan Asghar ◽  
Nisar Ahmad ◽  
Zaheer Abbas Gilani ◽  
...  

AbstractPurposeThe purpose of this study is the verification of intensity modulated radiation therapy (IMRT) head neck treatment planning with one-dimensional and two-dimensional (2D) dosimeters using imaging and radiation oncology core (IROC) Houston head & neck (H&N) phantom.MethodThe image of the H&N phantom was obtained by computed tomography scan which was then transferred to Pinnacle@3 treatment planning system (TPS) for treatment planning. The contouring of the target volumes and critical organ were done manually and dose constraints were set for each organ according to IROC prescription. The plan was optimised by adoptive convolution algorithm to meet the IROC criteria and collapse cone convolution algorithm calculated the delivered doses for treatment. Varian Clinac 2110 was used to deliver the treatment plan to the phantom, the process of irradiation and measurement were repeated three times for reproducibility and reliability. The treatment plan was verified by measuring the doses from thermoluminescent dosimeters (TLDs) and GafChromic external beam therapy 2 films. The agreement between the planned and delivered doses were checked by calculating the percentage dose differences, analysing their isodose line profiles and 2D gamma maps.ResultsThe average percent dose difference of 1·8% was obtained between computed doses by TPS and measured doses from TLDs, however these differences were found to be higher for organ at risk. The film dose profile was well in agreement with the planned dose distribution with distance to agreement of 1·5 mm. The gamma analysis of the computed and recorded doses passed the criteria of 3%/3 mm with passing percentages of >96%, which shows successful authentication of delivered doses for IMRT.ConclusionIMRT pre-treatment validation can be done with IROC anthropomorphic phantoms, which is essential for the delivery of modulated radiotherapies. It was concluded that films and TLDs can be used as quality assurance tools for IMRT.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
K. Abdul Haneefa ◽  
K. K. Shakir ◽  
A. Siddhartha ◽  
T. Siji Cyriac ◽  
M. M. Musthafa ◽  
...  

Dosimetric studies of mixed field photon beam intensity modulated radiation therapy (IMRT) for prostate cancer using pencil beam (PB) and collapsed cone convolution (CCC) algorithms using Oncentra MasterPlan treatment planning system (v. 4.3) are investigated in this study. Three different plans were generated using 6 MV, 15 MV, and mixed beam (both 6 and 15 MV). Fifteen patients with two sets of plans were generated: one by using PB and the other by using CCC for the same planning parameters and constraints except the beam energy. For each patient’s plan of high energy photons, one set of photoneutron measurements using solid state neutron track detector (SSNTD) was taken for this study. Mean percentage of V66 Gy in the rectum is 18.55±2.8, 14.58±2.1, and 16.77±4.7 for 6 MV, 15 MV, and mixed-energy plans, respectively. Mean percentage of V66 Gy in bladder is 16.54±2.1, 17.42±2.1, and 16.94±41.9 for 6 MV, 15 MV, and mixed-energy plans, respectively. Mixed fields neutron contribution at the beam entrance surface is 45.62% less than at 15 MV photon beam. Our result shows that, with negligible neutron contributions, mixed field IMRT has considerable dosimetric advantage.


Sign in / Sign up

Export Citation Format

Share Document