scholarly journals Pooled Versus Individualized Load–Velocity Profiling in the Free-Weight Back Squat and Power Clean

Author(s):  
Steve W. Thompson ◽  
David Rogerson ◽  
Alan Ruddock ◽  
Harry G. Banyard ◽  
Andrew Barnes

Purpose: This study compared pooled against individualized load–velocity profiles (LVPs) in the free-weight back squat and power clean. Methods: A total of 10 competitive weightlifters completed baseline 1-repetition maximum assessments in the back squat and power clean. Three incremental LVPs were completed, separated by 48 to 72 hours. Mean and peak velocity were measured via a linear-position transducer (GymAware). Linear and nonlinear (second-order polynomial) regression models were applied to all pooled and individualized LVP data. A combination of coefficient of variation (CV), intraclass correlation coefficient, typical error of measurement, and limits of agreement assessed between-subject variability and within-subject reliability. Acceptable reliability was defined a priori as intraclass correlation coefficient > .7 and CV < 10%. Results: Very high to practically perfect inverse relationships were evident in the back squat (r = .83–.96) and power clean (r = .83–.89) for both regression models; however, stronger correlations were observed in the individualized LVPs for both exercises (r = .85–.99). Between-subject variability was moderate to large across all relative loads in the back squat (CV = 8.2%–27.8%) but smaller in the power clean (CV = 4.6%–8.5%). The power clean met our criteria for acceptable reliability across all relative loads; however, the back squat revealed large CVs in loads ≥90% of 1-repetition maximum (13.1%–20.5%). Conclusions: Evidently, load–velocity characteristics are highly individualized, with acceptable levels of reliability observed in the power clean but not in the back squat (≥90% of 1-repetition maximum). If practitioners want to adopt load–velocity profiling as part of their testing and monitoring procedures, an individualized LVP should be utilized over pooled LVPs.

2018 ◽  
Vol 13 (6) ◽  
pp. 763-769 ◽  
Author(s):  
Harry G. Banyard ◽  
Kazunori Nosaka ◽  
Alex D. Vernon ◽  
G. Gregory Haff

Purpose: To examine the reliability of peak velocity (PV), mean propulsive velocity (MPV), and mean velocity (MV) in the development of load–velocity profiles (LVP) in the full-depth free-weight back squat performed with maximal concentric effort. Methods: Eighteen resistance-trained men performed a baseline 1-repetition maximum (1-RM) back-squat trial and 3 subsequent 1-RM trials used for reliability analyses, with 48-h intervals between trials. 1-RM trials comprised lifts from 6 relative loads including 20%, 40%, 60%, 80%, 90%, and 100% 1-RM. Individualized LVPs for PV, MPV, or MV were derived from loads that were highly reliable based on the following criteria: intraclass correlation coefficient (ICC) >.70, coefficient of variation (CV) ≤10%, and Cohen d effect size (ES) <0.60. Results: PV was highly reliable at all 6 loads. MPV and MV were highly reliable at 20%, 40%, 60%, 80%, and 90% but not 100% 1-RM (MPV: ICC = .66, CV = 18.0%, ES = 0.10, SEM = 0.04 m·s−1; MV: ICC = .55, CV = 19.4%, ES = 0.08, SEM = 0.04 m·s−1). When considering the reliable ranges, almost perfect correlations were observed for LVPs derived from PV20–100% (r = .91–.93), MPV20–90% (r = .92–.94), and MV20–90% (r = .94–.95). Furthermore, the LVPs were not significantly different (P > .05) between trials or movement velocities or between linear regression versus 2nd-order polynomial fits. Conclusions: PV20–100%, MPV20–90%, and MV20–90% are reliable and can be utilized to develop LVPs using linear regression. Conceptually, LVPs can be used to monitor changes in movement velocity and employed as a method for adjusting sessional training loads according to daily readiness.


2020 ◽  
Vol 15 (3) ◽  
pp. 441-443
Author(s):  
Kamila Grandolfi ◽  
Vandre Sosciarelli ◽  
Marcos Polito

Purpose: To compare performance in successive 1-repetition maximum (1RM) tests with the load known or unknown. Methods: Thirty-two resistance-trained men were randomly divided into 2 groups: load blinding (BLI; n = 16; age 28.1 [6.9] y, body mass 83.1 [11.5] kg, height 175.3 [5.8] cm) and load nonblinding (nBLI; n = 16; age 27.7 [4.1] y, body mass 83.2 [12.8] kg, height 178.7 [7.3] cm). The groups performed a 1RM test during 4 days (with an interval of 24–48 h) in the horizontal bench press with free weight. Results: In the BLI, there were no significant changes throughout the tests, with a difference of 1.6% between the first and fourth 1RM tests. In the nBLI, there was a significant interaction with time, and the values of the second (P = .03), third (P = .02), and fourth (P = .01) tests were higher than the first test; in addition, the fourth test was significantly higher than the second test (P = .02). The percentage difference between the last and first 1RM tests was 7.1%. The comparison between the groups demonstrated differences in the third (P = .04) and fourth (P = .02) tests with higher values in the nBLI. The intraclass correlation coefficient between the first and fourth 1RM tests was .93 for the BLI and .91 for the nBLI. Conclusion: BLI does not influence 1RM testing in the bench press exercise.


2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Bo Zhang ◽  
Jianjun Gu ◽  
Xiaoxiao Zhang ◽  
Bin Yang ◽  
Zheng Wang ◽  
...  

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device.Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mmHg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated.Results. All parameters showed good intraobserver reliability (Cronbach’s alpha; intraclass correlation coefficient,α, ICC > 0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated.Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15–75 mmHg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Lloyd Roberts ◽  
Tom Rozen ◽  
Deirdre Murphy ◽  
Adam Lawler ◽  
Mark Fitzgerald ◽  
...  

Abstract Background Multiple screening Duplex ultrasound scans (DUS) are performed in trauma patients at high risk of deep vein thrombosis (DVT) in the intensive care unit (ICU). Intensive care physician performed compression ultrasound (IP-CUS) has shown promise as a diagnostic test for DVT in a non-trauma setting. Whether IP-CUS can be used as a screening test in trauma patients is unknown. Our study aimed to assess the agreement between IP-CUS and vascular sonographer performed DUS for proximal lower extremity deep vein thrombosis (PLEDVT) screening in high-risk trauma patients in ICU. Methods A prospective observational study was conducted at the ICU of Alfred Hospital, a major trauma center in Melbourne, Australia, between Feb and Nov 2015. All adult major trauma patients admitted with high risk for DVT were eligible for inclusion. IP-CUS was performed immediately before or after DUS for PLEDVT screening. The paired studies were repeated twice weekly until the DVT diagnosis, death or ICU discharge. Written informed consent from the patient, or person responsible, or procedural authorisation, was obtained. The individuals performing the scans were blinded to the others’ results. The agreement analysis was performed using Cohen’s Kappa statistics and intraclass correlation coefficient for repeated binary measurements. Results During the study period, 117 patients had 193 pairs of scans, and 45 (39%) patients had more than one pair of scans. The median age (IQR) was 47 (28–68) years with 77% males, mean (SD) injury severity score 27.5 (9.53), and a median (IQR) ICU length of stay 7 (3.2–11.6) days. There were 16 cases (13.6%) of PLEDVT with an incidence rate of 2.6 (1.6–4.2) cases per 100 patient-days in ICU. The overall agreement was 96.7% (95% CI 94.15–99.33). The Cohen’s Kappa between the IP-CUS and DUS was 0.77 (95% CI 0.59–0.95), and the intraclass correlation coefficient for repeated binary measures was 0.75 (95% CI 0.67–0.81). Conclusions There is a substantial agreement between IP-CUS and DUS for PLEDVT screening in trauma patients in ICU with high risk for DVT. Large multicentre studies are needed to confirm this finding.


Author(s):  
Daniela Claessens ◽  
Alexander K. Schuster ◽  
Ronald V. Krüger ◽  
Marian Liegl ◽  
Laila Singh ◽  
...  

AbstractIn this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.


Sign in / Sign up

Export Citation Format

Share Document