scholarly journals Occurrence of Mycobacteria in Water Treatment Lines and in Water Distribution Systems

2002 ◽  
Vol 68 (11) ◽  
pp. 5318-5325 ◽  
Author(s):  
Corinne Le Dantec ◽  
Jean-Pierre Duguet ◽  
Antoine Montiel ◽  
Nadine Dumoutier ◽  
Sylvie Dubrou ◽  
...  

ABSTRACT The frequency of recovery of atypical mycobacteria was estimated in two treatment plants providing drinking water to Paris, France, at some intermediate stages of treatment. The two plants use two different filtration processes, rapid and slow sand filtration. Our results suggest that slow sand filtration is more efficient for removing mycobacteria than rapid sand filtration. In addition, our results show that mycobacteria can colonize and grow on granular activated carbon and are able to enter distribution systems. We also investigated the frequency of recovery of mycobacteria in the water distribution system of Paris (outside buildings). The mycobacterial species isolated from the Paris drinking water distribution system are different from those isolated from the water leaving the treatment plants. Saprophytic mycobacteria (present in 41.3% of positive samples), potentially pathogenic mycobacteria (16.3%), and unidentifiable mycobacteria (54.8%) were isolated from 12 sites within the Paris water distribution system. Mycobacterium gordonae was preferentially recovered from treated surface water, whereas Mycobacterium nonchromogenicum was preferentially recovered from groundwater. No significant correlations were found among the presence of mycobacteria, the origin of water, and water temperature.

2016 ◽  
Vol 4 (1) ◽  
Author(s):  
Vicente Gomez-Alvarez ◽  
Randy P. Revetta

We report here the draft genome sequences of four Mycobacterium chelonae strains from biofilms subjected to a “chlorine burn” in a chloraminated drinking water distribution system simulator. These opportunistic pathogens have been detected in hospital and municipal water distribution systems, in which biofilms have been recognized as an important factor for their persistence.


2021 ◽  
Vol 2139 (1) ◽  
pp. 012013
Author(s):  
C A Bonilla-Granados ◽  
N J Cely-Calixto ◽  
G A Carrillo Soto

Abstract Drinking-water distribution systems are generally designed with methodologies based on trial-and-error tests, which generate feasible results. However, these trials are not the most economical and reliable solution since they do not consider the optimization of the network. For the present work, the hydraulic model of the drinking water distribution network of San José de Cúcuta, Colombia, was optimized by applying the concept of resilience rate and minimum cost. The development of the work consisted of the hydraulic modeling of the physical components of the network in EPANET software, as well as the application of calculations of the connectivity coefficient and the unitary power of each section. With the data obtained from the modeling and calculations, the physical parameters were optimized, and the cost-benefit ratio was estimated. It was found that the current drinking water distribution system does not have a power surplus to overcome a system failure. The optimization increased the total energy surplus of the network (261%) and the resilience rate (585%). Also, the connectivity coefficient was improved with an average value of 0.95. The hydraulic optimization methodology applied resulted in a network resilient to system failures.


2019 ◽  
Vol 5 (10) ◽  
pp. 1689-1698
Author(s):  
Xu Ma ◽  
Guiwei Li ◽  
Ying Yu ◽  
Ruya Chen ◽  
Yao Zhang ◽  
...  

Discoloration problems have occurred in drinking water distribution systems continuously for several years in a rural area of eastern China.


2007 ◽  
Vol 73 (11) ◽  
pp. 3755-3758 ◽  
Author(s):  
Talis Juhna ◽  
Dagne Birzniece ◽  
Janis Rubulis

ABSTRACT The effect of phosphorus addition on survival of Escherichia coli in an experimental drinking water distribution system was investigated. Higher phosphorus concentrations prolonged the survival of culturable E. coli in water and biofilms. Although phosphorus addition did not affect viable but not culturable (VBNC) E. coli in biofilms, these structures could act as a reservoir of VBNC forms of E. coli in drinking water distribution systems.


2016 ◽  
Vol 4 (2) ◽  
Author(s):  
Vicente Gomez-Alvarez ◽  
Stacy Pfaller ◽  
Randy P. Revetta

We report the draft genomes of two Sphingopyxis sp. strains isolated from a chloraminated drinking water distribution system simulator. Both strains are ubiquitous residents and early colonizers of water distribution systems. Genomic annotation identified a class 1 integron ( intI1 ) gene associated with sulfonamide ( sul1 ) and puromycin ( pac ) antibiotic resistance genes.


2010 ◽  
Vol 76 (16) ◽  
pp. 5631-5635 ◽  
Author(s):  
Pei-Ying Hong ◽  
Chiachi Hwang ◽  
Fangqiong Ling ◽  
Gary L. Andersen ◽  
Mark W. LeChevallier ◽  
...  

ABSTRACT The applicability of 454 pyrosequencing to characterize bacterial biofilm communities from two water meters of a drinking water distribution system was assessed. Differences in bacterial diversity and composition were observed. A better understanding of the bacterial ecology of drinking water biofilms will allow for effective management of water quality in distribution systems.


2018 ◽  
Vol 19 (1) ◽  
pp. 291-302 ◽  
Author(s):  
Amanda Mussared ◽  
Rolando Fabris ◽  
Jan Vreeburg ◽  
Jenny Jelbart ◽  
Mary Drikas

Abstract Sediment accumulates in distribution systems over time, and can potentially result in dirty water events. The primary origin of these particles in most networks has not been examined. Controlled sediment resuspension (flushing) events were performed at 10 sites in a drinking water distribution system and repeated six months later to observe redeposition. Different patterns of sediment deposition observed are suspected to be related to particle origin. A large proportion of pipe sediment resuspended during the first flushing event was composed of iron, most likely arising from corrosion of distribution system infrastructure. This sediment appears to play a role in sheltering microbial cells from secondary disinfection. In this study, a source of particles was identified that may provide an alternate explanation for the presence of iron deposits in systems not dominated by iron pipework.


2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


2009 ◽  
Vol 43 (20) ◽  
pp. 5005-5014 ◽  
Author(s):  
Jeffrey G. Szabo ◽  
Christopher A. Impellitteri ◽  
Shekar Govindaswamy ◽  
John S. Hall

Sign in / Sign up

Export Citation Format

Share Document