scholarly journals Effect of Phosphorus on Survival of Escherichia coli in Drinking Water Biofilms

2007 ◽  
Vol 73 (11) ◽  
pp. 3755-3758 ◽  
Author(s):  
Talis Juhna ◽  
Dagne Birzniece ◽  
Janis Rubulis

ABSTRACT The effect of phosphorus addition on survival of Escherichia coli in an experimental drinking water distribution system was investigated. Higher phosphorus concentrations prolonged the survival of culturable E. coli in water and biofilms. Although phosphorus addition did not affect viable but not culturable (VBNC) E. coli in biofilms, these structures could act as a reservoir of VBNC forms of E. coli in drinking water distribution systems.

2019 ◽  
Vol 5 (10) ◽  
pp. 1689-1698
Author(s):  
Xu Ma ◽  
Guiwei Li ◽  
Ying Yu ◽  
Ruya Chen ◽  
Yao Zhang ◽  
...  

Discoloration problems have occurred in drinking water distribution systems continuously for several years in a rural area of eastern China.


2013 ◽  
Vol 6 (1) ◽  
pp. 25-31 ◽  
Author(s):  
L. Mezule ◽  
S. Larsson ◽  
T. Juhna

Abstract. Sporadic detection of live (viable) Escherichia coli in drinking water and biofilm with molecular methods but not with standard plate counts has raised concerns about the reliability of this indicator in the surveillance of drinking water safety. The aim of this study was to determine spatial distribution of different viability forms of E. coli in a drinking water distribution system which complies with European Drinking Water Directive (98/83/EC). For two years coupons (two week old) and pre-concentrated (100 times with ultrafilters) water samples were collected after treatment plants and from four sites in the distribution network at several distances. The samples were analyzed for total, viable (able to divide as DVC-FISH positive) and cultivable E. coli. The results showed that low numbers of E. coli enters the distribution sytem from the treatment plants and tend to accumulate in the biofilm of water distribution system. Almost all of the samples contained metabolically active E. coli in the range of 1 to 50 cells per litre or cm2 which represented approximately 53% of all E. coli detected. The amount of viable E. coli significantly increased into the network irrespective of the season. The study has shown that DVC-FISH method in combination with water pre-concentration and biofilm sampling allows to better understand the behaviour of E. coli in water distribution networks, thus, it provides new evidences for water safety control.


2006 ◽  
Vol 6 (2) ◽  
pp. 147-151 ◽  
Author(s):  
X.-J. Zhang ◽  
W. Lu

Biofilm growth in drinking water distribution systems was studied in an annular reactor system which was designed to model the hydraulic conditions in water mains. Experiments were performed with chlorine-free water as well as with different disinfectant (chlorine or chloramine) residuals and different AOC concentrations added to the reactor influent to examine the effect of disinfectant residuals and AOC concentrations on biofilm accumulation and planktonic cell numbers. The dynamic parameters of bacteria growth were calculated in water with different disinfectant (chlorine or chloramine) and the results indicated that monochloramine may be more effective than free chlorine for control of biofilm accumulation.


2003 ◽  
Vol 3 (1-2) ◽  
pp. 239-246 ◽  
Author(s):  
G. Kastl ◽  
I. Fisher ◽  
V. Jegatheesan ◽  
J. Chandy ◽  
K. Clarkson

Nearly all drinking water distribution systems experience a “natural” reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the “optimum level”, considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne’s Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water’s Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.


2016 ◽  
Vol 4 (1) ◽  
Author(s):  
Vicente Gomez-Alvarez ◽  
Randy P. Revetta

We report here the draft genome sequences of four Mycobacterium chelonae strains from biofilms subjected to a “chlorine burn” in a chloraminated drinking water distribution system simulator. These opportunistic pathogens have been detected in hospital and municipal water distribution systems, in which biofilms have been recognized as an important factor for their persistence.


2002 ◽  
Vol 68 (11) ◽  
pp. 5318-5325 ◽  
Author(s):  
Corinne Le Dantec ◽  
Jean-Pierre Duguet ◽  
Antoine Montiel ◽  
Nadine Dumoutier ◽  
Sylvie Dubrou ◽  
...  

ABSTRACT The frequency of recovery of atypical mycobacteria was estimated in two treatment plants providing drinking water to Paris, France, at some intermediate stages of treatment. The two plants use two different filtration processes, rapid and slow sand filtration. Our results suggest that slow sand filtration is more efficient for removing mycobacteria than rapid sand filtration. In addition, our results show that mycobacteria can colonize and grow on granular activated carbon and are able to enter distribution systems. We also investigated the frequency of recovery of mycobacteria in the water distribution system of Paris (outside buildings). The mycobacterial species isolated from the Paris drinking water distribution system are different from those isolated from the water leaving the treatment plants. Saprophytic mycobacteria (present in 41.3% of positive samples), potentially pathogenic mycobacteria (16.3%), and unidentifiable mycobacteria (54.8%) were isolated from 12 sites within the Paris water distribution system. Mycobacterium gordonae was preferentially recovered from treated surface water, whereas Mycobacterium nonchromogenicum was preferentially recovered from groundwater. No significant correlations were found among the presence of mycobacteria, the origin of water, and water temperature.


2021 ◽  
Vol 2139 (1) ◽  
pp. 012013
Author(s):  
C A Bonilla-Granados ◽  
N J Cely-Calixto ◽  
G A Carrillo Soto

Abstract Drinking-water distribution systems are generally designed with methodologies based on trial-and-error tests, which generate feasible results. However, these trials are not the most economical and reliable solution since they do not consider the optimization of the network. For the present work, the hydraulic model of the drinking water distribution network of San José de Cúcuta, Colombia, was optimized by applying the concept of resilience rate and minimum cost. The development of the work consisted of the hydraulic modeling of the physical components of the network in EPANET software, as well as the application of calculations of the connectivity coefficient and the unitary power of each section. With the data obtained from the modeling and calculations, the physical parameters were optimized, and the cost-benefit ratio was estimated. It was found that the current drinking water distribution system does not have a power surplus to overcome a system failure. The optimization increased the total energy surplus of the network (261%) and the resilience rate (585%). Also, the connectivity coefficient was improved with an average value of 0.95. The hydraulic optimization methodology applied resulted in a network resilient to system failures.


1998 ◽  
Vol 64 (1) ◽  
pp. 197-202 ◽  
Author(s):  
I. Sibille ◽  
T. Sime-Ngando ◽  
L. Mathieu ◽  
J. C. Block

ABSTRACT The development of bacterial communities in drinking water distribution systems leads to a food chain which supports the growth of macroorganisms incompatible with water quality requirements and esthetics. Nevertheless, very few studies have examined the microbial communities in drinking water distribution systems and their trophic relationships. This study was done to quantify the microbial communities (especially bacteria and protozoa) and obtain direct and indirect proof of protozoan feeding on bacteria in two distribution networks, one of GAC water (i.e., water filtered on granular activated carbon) and the other of nanofiltered water. The nanofiltered water-supplied network contained no organisms larger than bacteria, either in the water phase (on average, 5 × 107bacterial cells liter−1) or in the biofilm (on average, 7 × 106 bacterial cells cm−2). No protozoa were detected in the whole nanofiltered water-supplied network (water plus biofilm). In contrast, the GAC water-supplied network contained bacteria (on average, 3 × 108 cells liter−1 in water and 4 × 107 cells cm−2 in biofilm) and protozoa (on average, 105cells liter−1 in water and 103 cells cm−2 in biofilm). The water contained mostly flagellates (93%), ciliates (1.8%), thecamoebae (1.6%), and naked amoebae (1.1%). The biofilm had only ciliates (52%) and thecamoebae (48%). Only the ciliates at the solid-liquid interface of the GAC water-supplied network had a measurable grazing activity in laboratory test (estimated at 2 bacteria per ciliate per h). Protozoan ingestion of bacteria was indirectly shown by adding Escherichia colito the experimental distribution systems. Unexpectedly, E. coli was lost from the GAC water-supplied network more rapidly than from the nanofiltered water-supplied network, perhaps because of the grazing activity of protozoa in GAC water but not in nanofiltered water. Thus, the GAC water-supplied network contained a functional ecosystem with well-established and structured microbial communities, while the nanofiltered water-supplied system did not. The presence of protozoa in drinking water distribution systems must not be neglected because these populations may regulate the autochthonous and allochthonous bacterial populations.


2016 ◽  
Vol 4 (2) ◽  
Author(s):  
Vicente Gomez-Alvarez ◽  
Stacy Pfaller ◽  
Randy P. Revetta

We report the draft genomes of two Sphingopyxis sp. strains isolated from a chloraminated drinking water distribution system simulator. Both strains are ubiquitous residents and early colonizers of water distribution systems. Genomic annotation identified a class 1 integron ( intI1 ) gene associated with sulfonamide ( sul1 ) and puromycin ( pac ) antibiotic resistance genes.


Sign in / Sign up

Export Citation Format

Share Document