Film Cooling Performance for Cylindrical Holes Embedded in Contoured Craters: Effect of the Crater Depth

2019 ◽  
Vol 60 (6) ◽  
pp. 1068-1076 ◽  
Author(s):  
J. L. Fu ◽  
L. C. Bai ◽  
C. Zhang ◽  
P. F. Ju
2019 ◽  
Vol 36 (4) ◽  
pp. 425-433
Author(s):  
Wei Zhang ◽  
Shuai Zhou ◽  
Zhuang Wu ◽  
Guangchao Li ◽  
Zhihai Kou

Abstract Film cooling performance of one row of cylindrical holes integrated with saw-tooth slots was numerically studied at blowing ratios of 0.5, 1.0 1.5 and 2.0 respectively. The saw-tooth slot concept combines the advantages both of easy machining for the slot and of the high film cooling effectiveness caused by the anti-vortex induced by the shaped hole. The film holes have an inclination angles of 30°, length to diameter ratio of 4 and pitch to diameter ratio of 3. The corner angles of the saw-tooth are 60°, 90°, 120°, 150° and 180° respectively. The 180° corner angle corresponds to a standard transverse slot. The emphasis of this other is on the influence of the corner angles of the saw-tooth on film cooling effectiveness. The flow field and thermal field were obtained to explain the mechanism of film cooling performance improvement by the saw-tooth slot. The results show that the numerical data agrees with the experimental values for the cylindrical holes. Relatively small corner angles generate uniform local film cooling effectiveness and high spanwise averaged film cooling effectiveness due to the coolant ejected from the hole smoothly flowing into the slot. The effect of corner angles strongly depends on blowing ratios. The increase of x/D decreases the differences of film cooling effectiveness between various corner angles. At low blowing ratios, an anti-vortex can be found with the spanwise angle of 60° and 120°. At high blowing ratios, an anti-vortex can be found with the spanwise angle of 60°.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


Author(s):  
H. Abdeh ◽  
G. Barigozzi ◽  
S. Ravelli ◽  
S. Rouina

Abstract In this study a parametric analysis of the thermal performance of a nozzle vane cascade with a showerhead cooling system made of four rows of cylindrical holes was carried out by using the Pressure Sensitive Paint (PSP) technique. Coolant-to-mainstream blowing ratio (BR), density ratio (DR), main flow isentropic exit Mach number (Ma2is) and turbulence intensity level (Tu1) were the considered parameters. The cascade was tested in an atmospheric wind tunnel at Ma2is values ranging from 0.2 to 0.6, with an inlet turbulence intensity level of 1.6% and 9%, at variable injection conditions of BR = 2.0, 3.0, 4.0. Moreover, the influence of DR on the leading edge film cooling performance was investigated: testing was carried out at DR = 1.0, using nitrogen as foreign gas, and DR = 1.5, with carbon dioxide serving as coolant. In the near-hole region, higher BR and Ma2is resulted in higher effectiveness, while higher mainstream turbulence intensity reduced the thermal coverage in between the rows of holes, whatever the BR. Further downstream along the vane pressure side, the effectiveness was negatively affected by rising BR, but positively influenced by lowering the mainstream turbulence intensity. Moreover, a decrease in DR caused a reduction in the film cooling performance, whose extent depends on the injection condition.


2008 ◽  
Vol 131 (1) ◽  
Author(s):  
Ruwan P. Somawardhana ◽  
David G. Bogard

Recent studies have shown that film cooling with holes embedded in a shallow trench significantly improves cooling performance. In this study, the performance of shallow trench configurations was investigated for simulated deteriorated surface conditions, i.e., increased surface roughness and near-hole obstructions. Experiments were conducted on the suction side of a scaled-up simulated turbine vane. Results from the study indicated that as much as 50% degradation occurred with upstream obstructions, but downstream obstructions actually enhanced film cooling effectiveness. However, the transverse trench configuration performed significantly better than the traditional cylindrical holes, both with and without obstructions and almost eliminated the effects of both surface roughness and obstructions.


Author(s):  
Katharine L. Harrison ◽  
David G. Bogard

Recent studies have shown that film cooling adiabatic effectiveness can be significantly improved when holes are embedded in shallow, transverse trenches. In this study computational simulations were made using the commercial CFD code FLUENT to determine if the dramatic improvement in film cooling performance was predictable. Simulations were made of a baseline cylindrical hole configuration, and narrow and wide trench configurations. Simulations correctly predicted that the narrow trench outperformed the baseline row of cylindrical holes and the wide trench at all blowing ratios. Furthermore, the simulations showed that enhanced performance with the trench could be attributed to decreased separation of the coolant jets. The success of these predictions show that computational simulations can be used as a tool for studying and identifying promising film cooling configurations.


Author(s):  
D. H. Zhang ◽  
L. Sun ◽  
Q. Y. Chen ◽  
M. Lin ◽  
M. Zeng ◽  
...  

Embedding a row of typical cylindrical holes in a transverse slot can improve the cooling performance. Rectangular slots can increase the cooling effectiveness but is at the cost of decreasing of discharge coefficients. An experiment is conducted to examine the effects of an overlying transverse inclined trench on the film cooling performance of axial holes. Four different trench configurations are tested including the baseline inclined cylindrical holes. The influence of the geometry of the upstream lip of the exit trench and the geometry of the inlet trench on cooling performance is examined. Detailed film cooling effectiveness and heat transfer coefficients are obtained separately using the steady state IR thermography technique. The discharge coefficients are also acquired to evaluate the aerodynamic performance of different hole configurations. The results show that the film cooling holes with both ends embedded in slots can provide higher film cooling effectiveness and lower heat transfer coefficients; it also can provide higher discharge coefficients whilst retaining the mechanical strength of a row of discrete holes. The cooling performance and the aerodynamic performance of the holes with both ends embedded in inclined slots are superior to the holes with only exit trenched. To a certain extent, the configuration of the upstream lip of the exit trench affects the cooling performance of the downstream of the trench. The filleting for the film hole inlet avail the improvement of the cooling effect, but not for the film hole outlet. Comparing film cooling with embedded holes to unembedded holes, the overall heat flux ratio shows that the film holes with both ends embedded in slots and filleting for the film hole inlet can produce the highest heat flux reduction.


Author(s):  
Radheesh Dhanasegaran ◽  
Girish Venkatachalapathy ◽  
Nagarajan Gnanasekaran

A computational investigation is carried out to understand the film cooling performance and flow phenomenon on a pressure side of gas turbine airfoil. A specific geometry with multiple rows of cylindrical holes is considered on the pressure surface and opposite to which a flat surface is kept so as to avoid effect of imposed flow conditions. Meshing of the present model is done by using GAMBIT. Computations are carried out with K-epsilon Realizable model available in the commercial code FLUENT. The film cooling performance is discussed with flow structure followed by the effectiveness distribution on the pressure surface. The blowing ratio is varied from 0.4–2.4 and it is found that, at very low blowing ratio cases in the initial part of the pressure surface higher effectiveness values are observed but at higher blowing ratio these values become very low whereas close to the trailing edge side the effectiveness distribution is just the reverse. It was found that the optimum blowing ratio was close to unity where better flow and temperature distribution were observed.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo ◽  
Ying-ni Zhai

This paper presents an experimental and numerical investigation on the film cooling with different coolant feeding channel structures. Two ribbed cross-flow channels with rib-orientation of 135° and 45° respectively and the plenum coolant channel have been studied and compared to find out the effect of rib orientation on the film cooling performances of cylindrical holes. The film cooling effectiveness and heat transfer coefficient were measured by the transient heat transfer measurement technique with narrow-band thermochromic liquid crystal. Numerical simulations with realizable k-ε turbulence model were also performed to analyze the flow mechanism. The results show that the coolant channel structure has a notable effect on the flow structure of film jet which is the most significant mechanism affecting the film cooling performance. Generally, film cooling cases fed with ribbed cross-flow channels have asymmetric counter-rotating vortex structures and related asymmetric temperature distributions, which make the film cooling effectiveness and the heat transfer coefficient distributions asymmetric to the hole centerline. The discharge coefficient of the 45° rib case is the lowest among the three cases under all the blowing ratios. And the plenum case has higher discharge coefficient than the 135° rib case under low blowing ratio. With the increase of blowing ratio, the discharge coefficient of the 135° rib case gets larger than the plenum case gradually, because the vortex in the upper half region of the coolant channel rotates in the same direction with the film hole inclination direction and makes the jet easy to flow into the film hole in the 135° rib case.


Author(s):  
Alok Dhungel ◽  
Yiping Lu ◽  
Wynn Phillips ◽  
Srinath V. Ekkad ◽  
James Heidmann

The primary focus of this paper is to study the film cooling performance for a row of cylindrical holes each supplemented with two symmetrical anti vortex holes which branch out from the main holes. The anti-vortex design was originally developed at NASA-Glenn Research Center by Dr. James Heidmann, co-author of this paper. This “anti-vortex” design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film cooling holes. The geometry and orientation of the anti vortex holes greatly affect the cooling performance downstream, which is thoroughly investigated. By performing experiments at a single mainstream Reynolds number of 9683 based on the free stream velocity and film hole diameter at four different coolant-to-mainstream blowing ratio of 0.5, 1, 1.5, 2 and using the transient IR thermography technique, detailed film cooling effectiveness and heat transfer coefficients are obtained simultaneously from a single test. When the anti vortex holes are nearer to the primary film cooling holes and are developing from the base of the primary holes, better film cooling is accomplished as compared to other anti vortex hole orientations. When the anti vortex holes are laid back in the upstream region, film cooling diminishes considerably. Although an enhancement in heat transfer coefficient is seen in cases with high film cooling effectiveness, the overall heat flux ratio as compared to standard cylindrical holes is much lower. Thus cases with anti vortex holes placed near the main holes certainly show promising results.