Calculations of Polarizabilities and Their Gradients for Electron Energy-Loss Spectroscopy

2008 ◽  
Vol 73 (11) ◽  
pp. 1509-1524 ◽  
Author(s):  
Ivana Paidarová ◽  
Roman Čurík ◽  
Stephan P. A. Sauer

We illustrate for a set of small hydrocarbons, CH4, C2H4, C3H6 and C3H8, the important role of the electric dipole polarizability tensor and its geometric derivatives in theoretical models of electron energy-loss spectra (EELS). The coupled cluster linear response method together with Sadlej's polarized valence triple zeta basis set of atomic orbitals were used to calculate the polarizabilities and polarizability gradients. Incorporation of these ab initio data into the discrete momentum representation method (DMR) leads to perfect agreement between theory and collision experiments.

Author(s):  
P. Trebbia ◽  
P. Ballongue ◽  
C. Colliex

An effective use of electron energy loss spectroscopy for chemical characterization of selected areas in the electron microscope can only be achieved with the development of quantitative measurements capabilities.The experimental assembly, which is sketched in Fig.l, has therefore been carried out. It comprises four main elements.The analytical transmission electron microscope is a conventional microscope fitted with a Castaing and Henry dispersive unit (magnetic prism and electrostatic mirror). Recent modifications include the improvement of the vacuum in the specimen chamber (below 10-6 torr) and the adaptation of a new electrostatic mirror.The detection system, similar to the one described by Hermann et al (1), is located in a separate chamber below the fluorescent screen which visualizes the energy loss spectrum. Variable apertures select the electrons, which have lost an energy AE within an energy window smaller than 1 eV, in front of a surface barrier solid state detector RTC BPY 52 100 S.Q. The saw tooth signal delivered by a charge sensitive preamplifier (decay time of 5.10-5 S) is amplified, shaped into a gaussian profile through an active filter and counted by a single channel analyser.


Author(s):  
C. Colliex ◽  
P. Trebbia

The physical foundations for the use of electron energy loss spectroscopy towards analytical purposes, seem now rather well established and have been extensively discussed through recent publications. In this brief review we intend only to mention most recent developments in this field, which became available to our knowledge. We derive also some lines of discussion to define more clearly the limits of this analytical technique in materials science problems.The spectral information carried in both low ( 0<ΔE<100eV ) and high ( >100eV ) energy regions of the loss spectrum, is capable to provide quantitative results. Spectrometers have therefore been designed to work with all kinds of electron microscopes and to cover large energy ranges for the detection of inelastically scattered electrons (for instance the L-edge of molybdenum at 2500eV has been measured by van Zuylen with primary electrons of 80 kV). It is rather easy to fix a post-specimen magnetic optics on a STEM, but Crewe has recently underlined that great care should be devoted to optimize the collecting power and the energy resolution of the whole system.


Author(s):  
R. F. Egerton

An important parameter governing the sensitivity and accuracy of elemental analysis by electron energy-loss spectroscopy (EELS) or by X-ray emission spectroscopy is the signal/noise ratio of the characteristic signal.


Author(s):  
R.D. Leapman ◽  
C.R. Swyt

The intensity of a characteristic electron energy loss spectroscopy (EELS) image does not, in general, directly reflect the elemental concentration. In fact, the raw core loss image can give a misleading impression of the elemental distribution. This is because the measured core edge signal depends on the amount of plural scattering which can vary significantly from region to region in a sample. Here, we show how the method for quantifying spectra due to Egerton et al. can be extended to maps.


Author(s):  
L. Reimer ◽  
R. Oelgeklaus

Quantitative electron energy-loss spectroscopy (EELS) needs a correction for the limited collection aperture α and a deconvolution of recorded spectra for eliminating the influence of multiple inelastic scattering. Reversely, it is of interest to calculate the influence of multiple scattering on EELS. The distribution f(w,θ,z) of scattered electrons as a function of energy loss w, scattering angle θ and reduced specimen thickness z=t/Λ (Λ=total mean-free-path) can either be recorded by angular-resolved EELS or calculated by a convolution of a normalized single-scattering function ϕ(w,θ). For rotational symmetry in angle (amorphous or polycrystalline specimens) this can be realised by the following sequence of operations :(1)where the two-dimensional distribution in angle is reduced to a one-dimensional function by a projection P, T is a two-dimensional Fourier transform in angle θ and energy loss w and the exponent -1 indicates a deprojection and inverse Fourier transform, respectively.


Author(s):  
Eckhard Quandt ◽  
Stephan laBarré ◽  
Andreas Hartmann ◽  
Heinz Niedrig

Due to the development of semiconductor detectors with high spatial resolution -- e.g. charge coupled devices (CCDs) or photodiode arrays (PDAs) -- the parallel detection of electron energy loss spectra (EELS) has become an important alternative to serial registration. Using parallel detection for recording of energy spectroscopic large angle convergent beam patterns (LACBPs) special selected scattering vectors and small detection apertures lead to very low intensities. Therefore the very sensitive direct irradiation of a cooled linear PDA instead of the common combination of scintillator, fibre optic, and semiconductor has been investigated. In order to obtain a sufficient energy resolution the spectra are optionally magnified by a quadrupole-lens system.The detector used is a Hamamatsu S2304-512Q linear PDA with 512 diodes and removed quartz-glas window. The sensor size is 13 μm ∗ 2.5 mm with an element spacing of 25 μm. Along with the dispersion of 3.5 μm/eV at 40 keV the maximum energy resolution is limited to about 7 eV, so that a magnification system should be attached for experiments requiring a better resolution.


Author(s):  
J. Kulik ◽  
Y. Lifshitz ◽  
G.D. Lempert ◽  
S. Rotter ◽  
J.W. Rabalais ◽  
...  

Carbon thin films with diamond-like properties have generated significant interest in condensed matter science in recent years. Their extreme hardness combined with insulating electronic characteristics and high thermal conductivity make them attractive for a variety of uses including abrasion resistant coatings and applications in electronic devices. Understanding the growth and structure of such films is therefore of technological interest as well as a goal of basic physics and chemistry research. Recent investigations have demonstrated the usefulness of energetic ion beam deposition in the preparation of such films. We have begun an electron microscopy investigation into the microstructure and electron energy loss spectra of diamond like carbon thin films prepared by energetic ion beam deposition.The carbon films were deposited using the MEIRA ion beam facility at the Soreq Nuclear Research Center in Yavne, Israel. Mass selected C+ beams in the range 50 to 300 eV were directed onto Si {100} which had been etched with HF prior to deposition.


Author(s):  
D W McComb ◽  
R S Payne ◽  
P L Hansen ◽  
R Brydson

Electron energy-loss near-edge structure (ELNES) is an effective probe of the local geometrical and electronic environment around particular atomic species in the solid state. Energy-loss spectra from several silicate minerals were mostly acquired using a VG HB501 STEM fitted with a parallel detector. Typically a collection angle of ≈8mrad was used, and an energy resolution of ≈0.5eV was achieved.Other authors have indicated that the ELNES of the Si L2,3-edge in α-quartz is dominated by the local environment of the silicon atom i.e. the SiO4 tetrahedron. On this basis, and from results on other minerals, the concept of a coordination fingerprint for certain atoms in minerals has been proposed. The concept is useful in some cases, illustrated here using results from a study of the Al2SiO5 polymorphs (Fig.l). The Al L2,3-edge of kyanite, which contains only 6-coordinate Al, is easily distinguished from andalusite (5- & 6-coordinate Al) and sillimanite (4- & 6-coordinate Al). At the Al K-edge even the latter two samples exhibit differences; with careful processing, the fingerprint for 4-, 5- and 6-coordinate aluminium may be obtained.


Author(s):  
David C. Joy ◽  
Suichu Luo ◽  
John R. Dunlap ◽  
Dick Williams ◽  
Siqi Cao

In Physics, Chemistry, Materials Science, Biology and Medicine, it is very important to have accurate information about the stopping power of various media for electrons, that is the average energy loss per unit pathlength due to inelastic Coulomb collisions with atomic electrons of the specimen along their trajectories. Techniques such as photoemission spectroscopy, Auger electron spectroscopy, and electron energy loss spectroscopy have been used in the measurements of electron-solid interaction. In this paper we present a comprehensive technique which combines experimental and theoretical work to determine the electron stopping power for various materials by electron energy loss spectroscopy (EELS ). As an example, we measured stopping power for Si, C, and their compound SiC. The method, results and discussion are described briefly as below.The stopping power calculation is based on the modified Bethe formula at low energy:where Neff and Ieff are the effective values of the mean ionization potential, and the number of electrons participating in the process respectively. Neff and Ieff can be obtained from the sum rule relations as we discussed before3 using the energy loss function Im(−1/ε).


Sign in / Sign up

Export Citation Format

Share Document