scholarly journals A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Nucleic Acid Amplification Tests for Tuberculous Meningitis

2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Ali Pormohammad ◽  
Mohammad Javad Nasiri ◽  
Timothy D. McHugh ◽  
Seyed Mohammad Riahi ◽  
Nathan C. Bahr

ABSTRACTThe diagnosis of tuberculous meningitis (TBM) is difficult and poses a significant challenge to physicians worldwide. Recently, nucleic acid amplification (NAA) tests have shown promise for the diagnosis of TBM, although their performance has been variable. We undertook a systematic review and meta-analysis to evaluate the diagnostic accuracy of NAA tests with cerebrospinal fluid (CSF) samples against that of culture as the reference standard or a combined reference standard (CRS) for TBM. We searched the Embase, PubMed, Web of Science, and Cochrane Library databases for the relevant records. The QUADAS-2 tool was used to assess the quality of the studies. Diagnostic accuracy measures (i.e., sensitivity and specificity) were pooled with a random-effects model. All statistical analyses were performed with STATA (version 14 IC; Stata Corporation, College Station, TX, USA), Meta-DiSc (version 1.4 for Windows; Cochrane Colloquium, Barcelona, Spain), and RevMan (version 5.3; The Nordic Cochrane Centre, the Cochrane Collaboration, Copenhagen, Denmark) software. Sixty-three studies comprising 1,381 cases of confirmed TBM and 5,712 non-TBM controls were included in the final analysis. These 63 studies were divided into two groups comprising 71 data sets (43 in-house tests and 28 commercial tests) that used culture as the reference standard and 24 data sets (21 in-house tests and 3 commercial tests) that used a CRS. Studies which used a culture reference standard had better pooled summary estimates than studies which used CRS. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the NAA tests against culture were 82% (95% confidence interval [CI], 75 to 87%), 99% (95% CI, 98 to 99%), 58.6 (95% CI, 35.3 to 97.3), and 0.19 (95% CI, 0.14 to 0.25), respectively. The pooled sensitivity, specificity, PLR, and NLR of NAA tests against CRS were 68% (95% CI, 41 to 87%), 98% (95% CI, 95 to 99%), 36.5 (95% CI, 15.6 to 85.3), and 0.32 (95% CI, 0.15 to 0.70), respectively. The analysis has demonstrated that the diagnostic accuracy of NAA tests is currently insufficient for them to replace culture as a lone diagnostic test. NAA tests may be used in combination with culture due to the advantage of time to result and in scenarios where culture tests are not feasible. Further work to improve NAA tests would benefit from the availability of standardized reference standards and improvements to the methodology.

2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Emily MacLean ◽  
Giorgia Sulis ◽  
Claudia M. Denkinger ◽  
James C. Johnston ◽  
Madhukar Pai ◽  
...  

ABSTRACT Invasive collection methods are often required to obtain samples for the microbiological evaluation of children with presumptive pulmonary tuberculosis (PTB). Nucleic acid amplification testing of easier-to-collect stool samples could be a noninvasive method of diagnosing PTB. We conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of testing stool with the Xpert MTB/RIF assay (“stool Xpert”) for childhood PTB. Four databases were searched for publications from January 2008 to June 2018. Studies assessing the diagnostic accuracy among children of stool Xpert compared to a microbiological reference standard of conventional specimens tested by mycobacterial culture or Xpert were eligible. Bivariate random-effects meta-analyses were performed to calculate pooled sensitivity and specificity of stool Xpert against the reference standard. From 1,589 citations, 9 studies (n = 1,681) were included. Median participant ages ranged from 1.3 to 10.6 years. Protocols for stool processing and testing varied substantially, with differences in reagents and methods of homogenization and filtering. Against the microbiological reference standard, the pooled sensitivity and specificity of stool Xpert were 67% (95% confidence interval [CI], 52 to 79%) and 99% (95% CI, 98 to 99%), respectively. Sensitivity was higher among children with HIV (79% [95% CI, 68 to 87%] versus 60% [95% CI, 44 to 74%] among HIV-uninfected children). Heterogeneity was high. Data were insufficient for subgroup analyses among children under the age of 5 years, the most relevant target population. Stool Xpert could be a noninvasive method of ruling in PTB in children, particularly those with HIV. However, studies focused on children under 5 years of age are needed, and generalizability of the evidence is limited by the lack of standardized stool preparation and testing protocols.


2020 ◽  
pp. 084653712090206 ◽  
Author(s):  
Waleed Abdellatif ◽  
Mahmoud Ahmed Ebada ◽  
Souad Alkanj ◽  
Ahmed Negida ◽  
Nicolas Murray ◽  
...  

Purpose: In this systematic review and meta-analysis, we aimed to investigate the accuracy of dual-energy computed tomography (DECT) in the detection of acute pulmonary embolism (PE). Methods: We searched Medline (via PubMed), EBSCO, Web of Science, Scopus, and the Cochrane Library for relevant published studies. We selected studies assessing the accuracy of DECT in the detection of PE. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 tool. Meta-analysis was performed to calculate mean estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). The summary receiver operating characteristic (sROC) curve was drawn to get the Cochran Q-index and the area under the curve (AUC). Results: Seven studies were included in our systematic review. Of the 182 patients included, 108 patients had PEs. The pooled analysis showed an overall sensitivity and specificity of 88.9% (95% confidence interval [CI]: 81.4%-94.1%) and 94.6% (95% CI: 86.7%-98.5%), respectively. The pooled PLR was 8.186 (95% CI: 3.726-17.986), while the pooled NLR was 0.159 (95% CI: 0.093-0.270). Cochran-Q was 0.8712, and AUC was 0.935 in the sROC curve. Conclusion: Dual-energy computed tomography shows high sensitivity, specificity, and diagnostic accuracy in the detection of acute PE. The high PLR highlights the high clinical importance of DECT as a prevalence-independent, rule-in test. Studies with a larger sample size with standardized reference tests are still needed to increase the statistical power of the study and support these findings.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243765
Author(s):  
Yanqin Shen ◽  
Likui Fang ◽  
Bo Ye ◽  
Guocan Yu

Background Abdominal tuberculosis is a severe extrapulmonary tuberculosis, which can lead to serious complications. Early diagnosis and treatment are very important for the prognosis and the diagnosis of abdominal tuberculosis is still difficult. This study aims to evaluate the diagnostic accuracy of nucleic acid amplification tests (NAATs) for abdominal tuberculosis using meta-analysis method. Methods We will search PubMed, the Cochrane Library, Embase, China National Knowledge Infrastructure, and the Wanfang database for studies evaluating the diagnostic accuracy of NAATs for abdominal tuberculosis until May 2020. We will include a systematic review and meta-analysis that evaluated the accuracy of NAATs for abdominal tuberculosis. Any types of study design with full text will be sought and included. The risk of bias will be assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Stata version 15.0 with the midas command packages will be used to carry out meta-analyses. Results The results will provide clinical evidence for diagnostic accuracy of NAATs for abdominal tuberculosis, and this systematic review and meta-analysis will be submitted to a peer-reviewed journal for publication. Conclusion This overview will provide evidence of NAATs for diagnosis of abdominal tuberculosis. Systematic review registration INPLASY202060030.


2020 ◽  
Vol 58 (9) ◽  
Author(s):  
Ke Chen ◽  
Sarfraz Ahmed ◽  
Yun-Juan Sheng ◽  
Changfeng Sun ◽  
Cun-Liang Deng ◽  
...  

ABSTRACT Timely and accurate methods for detecting Clostridium perfringens-associated diseases (CPAD) are crucial to improve patient care. A number of studies have evaluated the accuracy of nucleic acid amplification tests (NAAT) in detecting CPAD, but decisive results about their effectiveness have not been reported. We conducted a meta-analysis to evaluate the diagnostic performance of NAAT for detecting C. perfringens in clinical diarrheal samples. Five databases including PubMed, Embase, Scopus, Web of Science, and the Cochrane library were systematically probed for studies published before 6 December 2019. From 2,632 citations, we identified five eligible studies comprising 817 samples. Three studies (n = 695 samples) compared NAAT with a microbiological culture while the other three studies (n = 322 samples) compared NAAT with an immunoassay. NAAT revealed higher diagnostic accuracy against immunoassay (sensitivity, 0.53 [95% confidence interval [CI], 0.35 to 0.7]; specificity, 0.97 [95% CI, 0.95 to 0.99]; positive likelihood ratio [PLR], 23.2 [95% CI, 3.49 to 153.98]; negative likelihood ratio [NLR], 0.25 [95% CI, 0 to 245.28]; diagnostic odds ratio [DOR], 74.11 [95% CI, 2.11 to 2,593.7]) than microbiological culture (sensitivity, 0.31 [95% CI, 0.22 to 0.41]; specificity, 0.95 [95% CI, 0.93 to 0.97]; PLR, 11.56 [95% CI, 3.87 to 34.6]; NLR, 0.57 [95% CI, 0.27 to 1.21]; DOR, 18.1 [95% CI, 4.83 to 67.8]). NAAT pooled specificity was consistently ≥95% against that of applied reference standards. A meta-regression and subgroup analysis of sample condition, gene target, study design, and reference standards could not explain the heterogeneity (P > 0.05) in the diagnostic efficiency. The analysis has demonstrated that the diagnostic accuracy of NAAT is relatively insufficient to replace traditional reference standards as a single diagnostic test. NAAT can be applied in combination with microbiological culture because of the advantage of time to result and in scenarios where traditional tests are not feasible. Further investigations in this direction with larger sample sizes are still warranted to support our findings.


10.2196/26167 ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. e26167
Author(s):  
Tien Yun Yang ◽  
Li Huang ◽  
Shwetambara Malwade ◽  
Chien-Yi Hsu ◽  
Yang Ching Chen

Background Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide. Early diagnosis of AF is crucial for preventing AF-related morbidity, mortality, and economic burden, yet the detection of the disease remains challenging. The 12-lead electrocardiogram (ECG) is the gold standard for the diagnosis of AF. Because of technological advances, ambulatory devices may serve as convenient screening tools for AF. Objective The objective of this review was to investigate the diagnostic accuracy of 2 relatively new technologies used in ambulatory devices, non-12-lead ECG and photoplethysmography (PPG), in detecting AF. We performed a meta-analysis to evaluate the diagnostic accuracy of non-12-lead ECG and PPG compared to the reference standard, 12-lead ECG. We also conducted a subgroup analysis to assess the impact of study design and participant recruitment on diagnostic accuracy. Methods This systematic review and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. MEDLINE and EMBASE were systematically searched for articles published from January 1, 2015 to January 23, 2021. A bivariate model was used to pool estimates of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and area under the summary receiver operating curve (SROC) as the main diagnostic measures. Study quality was evaluated using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool. Results Our search resulted in 16 studies using either non-12-lead ECG or PPG for detecting AF, comprising 3217 participants and 7623 assessments. The pooled estimates of sensitivity, specificity, PLR, NLR, and diagnostic odds ratio for the detection of AF were 89.7% (95% CI 83.2%-93.9%), 95.7% (95% CI 92.0%-97.7%), 20.64 (95% CI 10.10-42.15), 0.11 (95% CI 0.06-0.19), and 224.75 (95% CI 70.10-720.56), respectively, for the automatic interpretation of non-12-lead ECG measurements and 94.7% (95% CI 93.3%-95.8%), 97.6% (95% CI 94.5%-99.0%), 35.51 (95% CI 18.19-69.31), 0.05 (95% CI 0.04-0.07), and 730.79 (95% CI 309.33-1726.49), respectively, for the automatic interpretation of PPG measurements. Conclusions Both non-12-lead ECG and PPG offered high diagnostic accuracies for AF. Detection employing automatic analysis techniques may serve as a useful preliminary screening tool before administering a gold standard test, which generally requires competent physician analyses. Subgroup analysis indicated variations of sensitivity and specificity between studies that recruited low-risk and high-risk populations, warranting future validity tests in the general population. Trial Registration PROSPERO International Prospective Register of Systematic Reviews CRD42020179937; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=179937


2018 ◽  
Vol 20 (2) ◽  
pp. 164 ◽  
Author(s):  
Fajin Dong ◽  
Lei Zhang ◽  
Shuxia Wang ◽  
Duo Dong ◽  
Jinfeng Xu ◽  
...  

Aim: To evaluate the diagnostic accuracy of meniscal tears using B-mode ultrasound and high-frequency linear probe by conducting a systematic review and pooled meta-analysis. Material and methods: The Cochrane library, Embase, and Pubmed were searched for relevant studies up to 29 July 2017. The arthroscopy was used as the reference standard. The results were estimated by pooled sensitivity, specificity, diagnostic odds ratio, likelihood ratio, and the area under the summary receiver operating characteristic (SROC). Results: Seven prospective studies met the selection criteria, comprising 321meniscal tears from 472 patients. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the SROC curve were 88.80% (95%CI: 82.83-92.87), 84.66% (95%CI: 75.89-90.64), 5.79(95%CI: 3.66-9.15), 0.13 (95%CI: 0.09-0.20), and 43.74 (95%CI: 24.01-79.68), respectively. The area under the SROC curve was 93% (95%CI: 91-95). Conclusions: This meta-analysis indicates that 2-dimensional ultrasound is useful, and could be routinely used for estimating meniscal injuries in the human knee joint


2019 ◽  
Vol 32 (3) ◽  
Author(s):  
Colleen S. Kraft ◽  
J. Scott Parrott ◽  
Nancy E. Cornish ◽  
Matthew L. Rubinstein ◽  
Alice S. Weissfeld ◽  
...  

SUMMARY The evidence base for the optimal laboratory diagnosis of Clostridioides (Clostridium) difficile in adults is currently unresolved due to the uncertain performance characteristics and various combinations of tests. This systematic review evaluates the diagnostic accuracy of laboratory testing algorithms that include nucleic acid amplification tests (NAATs) to detect the presence of C. difficile. The systematic review and meta-analysis included eligible studies (those that had PICO [population, intervention, comparison, outcome] elements) that assessed the diagnostic accuracy of NAAT alone or following glutamate dehydrogenase (GDH) enzyme immunoassays (EIAs) or GDH EIAs plus C. difficile toxin EIAs (toxin). The diagnostic yield of NAAT for repeat testing after an initial negative result was also assessed. Two hundred thirty-eight studies met inclusion criteria. Seventy-two of these studies had sufficient data for meta-analysis. The strength of evidence ranged from high to insufficient. The uses of NAAT only, GDH-positive EIA followed by NAAT, and GDH-positive/toxin-negative EIA followed by NAAT are all recommended as American Society for Microbiology (ASM) best practices for the detection of the C. difficile toxin gene or organism. Meta-analysis of published evidence supports the use of testing algorithms that use NAAT alone or in combination with GDH or GDH plus toxin EIA to detect the presence of C. difficile in adults. There is insufficient evidence to recommend against repeat testing of the sample using NAAT after an initial negative result due to a lack of evidence of harm (i.e., financial, length of stay, or delay of treatment) as specified by the Laboratory Medicine Best Practices (LMBP) systematic review method in making such an assessment. Findings from this systematic review provide clarity to diagnostic testing strategies and highlight gaps, such as low numbers of GDH/toxin/PCR studies, in existing evidence on diagnostic performance, which can be used to guide future clinical research studies.


Sign in / Sign up

Export Citation Format

Share Document