Shear strength of disturbed regions with corroded stirrups in reinforced concrete beams

2010 ◽  
Vol 37 (8) ◽  
pp. 1045-1056 ◽  
Author(s):  
Christopher Suffern ◽  
Ahmed El-Sayed ◽  
Khaled Soudki

This paper reports experimental data on the structural performance of disturbed regions in reinforced concrete beams with corrosion damage to the embedded steel stirrups. A total of 15 reinforced concrete beams were constructed and tested. The test beams were 350 mm deep, 125 mm wide, and 1850 mm long. The beams were tested in three-point bending under a simply supported span of 1500 mm. Nine beams had the embedded stirrups subjected to accelerated corrosion. The test variables were the corrosion damage level and the shear span-to-depth ratio. The test results indicated that the corroded beams exhibited reduced shear strength in comparison to the uncorroded control specimens. The shear strength reduction was up to 53%. Furthermore, the reduction in shear strength due to the corrosion was found to be greater at smaller shear span-to-depth ratios.

2015 ◽  
Vol 22 (4) ◽  
pp. 491-499 ◽  
Author(s):  
Ahmed K. EL-SAYED ◽  
Raja R. HUSSAIN ◽  
Ahmed B. SHURAIM

The effect of stirrups damage due to corrosion on the shear strength and behaviour of reinforced concrete beams was experimentally investigated. A total of fourteen full-scale reinforced concrete beams were constructed and tested under four-point bending up to failure. The test beams were 200 mm wide, 350 mm deep, and 2800 mm long. The reinforcing stirrups of nine of the beams were subjected to accelerated corrosion prior to structural testing. The test variables were the corrosion damage level, spacing of stirrups, and shear span to depth ratio. The beams were tested under shear span to depth ratio of 2 or 1 representing short or deep members. The test results indicated that the corroded beams exhibited degradation in stiffness and shear strength in comparison to the uncorroded control specimens. This degradation appeared to increase as the corrosion level increases and as stirrup spacing as well as shear span to depth ratio decreases.


2014 ◽  
Vol 931-932 ◽  
pp. 468-472
Author(s):  
Piyoros Tasenhod ◽  
Jaruek Teerawong

Shear strength prediction of simple deep reinforced concrete beams by method of strut-and-tie model is presented in this paper. The tested specimens were designed according to Appendix A of ACI 318-11 code with variations of shear span-to-effective depth ratios and ratios of horizontal and vertical crack-controlling reinforcement. Test results revealed that at the same shear span-to-effective depth ratio, the various crack-controlling reinforcements significantly influenced on strength reduction coefficients of strut and failure modes. When the shear span-to-effective depth ratios were increased, failure modes changed from splitting diagonal strut to flexural-shear failure. Based on the test results, the proposed model was compared with Appendix A of ACI 318-11code.


2019 ◽  
Vol 22 (14) ◽  
pp. 2998-3010 ◽  
Author(s):  
Zhao-Hui Lu ◽  
Hai Li ◽  
Wengui Li ◽  
Yan-Gang Zhao ◽  
Zhuo Tang ◽  
...  

Reinforcement corrosion exhibits an adverse effect on the shear strength of reinforced concrete structures. In order to investigate the effects of chloride-induced corrosion of reinforcing steel on the shear behavior and failure pattern of reinforced concrete beams, a total of 24 reinforced concrete beams with different concrete strength grades and arrangements of stirrups were fabricated, among which 22 beams were subjected to accelerated corrosion to achieve different degrees of reinforcement corrosion. The failure pattern, crack propagation, load–displacement response, and ultimate strength of these beams were investigated under a standard four-point loading test in this study. Extensive comparative analysis was conducted to investigate the effects of the concrete strength, shear span-to-depth ratio, and stirrup type on the shear behavior of the corroded reinforced concrete beams. The results show that increasing the stirrup yielding strength is more effective in improving the shear strength of corroded reinforced concrete beams than that of concrete compressive strength. In terms of three types of stirrups, the shear strength of the beams with deformed HRB-335 is least sensitive to stirrup corrosion, followed by the beams with smooth HPB-235 and the beams with deformed HRB-400. The effect of the different stirrups on the shear strength depends on the corrosion degree of stirrup and shear span-to-depth ratio of the beam. The predicted results of shear strength of corroded reinforced concrete beams by a proposed analytical model are well consistent with the experimental results.


2017 ◽  
Vol 12 (2) ◽  
pp. 39-45 ◽  
Author(s):  
Pavlo Vegera ◽  
Rostyslav Vashkevych ◽  
Roman Khmil ◽  
Zinoviy Blikharskyy

Abstract In this article, results of experimental testing of reinforced concrete beams without transverse shear reinforcement are given. Three prototypes for improved testing methods were tested. The testing variable parameter was the shear span to the effective depth ratio. In the result of the tests we noticed that bearing capacity of RC beams is increased with the decreasing shear span to the effective depth ratio. The design method according to current codes was applied to test samples and it showed a significant discrepancy results. Than we proposed the improved design method using the adjusted value of shear strength of concrete CRd,c. The results obtained by the improved design method showed satisfactory reproducibility.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1711
Author(s):  
Changyong Li ◽  
Na Liang ◽  
Minglei Zhao ◽  
Kunqi Yao ◽  
Jie Li ◽  
...  

This paper is the outcome of experiments on the shear performance of reinforced concrete beams with approved composite-recycled aggregates. The strength grade of composite-recycled aggregate concrete (CRAC) was between 30 MPa and 60 MPa. The shear span-to-depth ratio varied from 1 to 3. The adaptability of HRB400 rebar, with critical yield strength of 400 MPa, used as stirrups was also verified. As the composite technology overcame the shortcomings of recycled coarse aggregate, CRAC had similar mechanical properties with those of conventional concrete. Details on the shear behaviors of test beams under a four-point loading test are presented. The results indicated that the changes of CRAC strain, stirrup strain, and shear-crack width depended on the failure patterns, which are controlled by the shear-span to depth ratio. The stirrups yield at the failure of reinforced CRAC beams. The shear cracking resistance and the shear capacity of reinforced CRAC beams can be predicted by the statistical equations. Based on the design codes GB50010, ACI318-19, Model Code 2010 and DIN-1045-1-2008 for conventional reinforced concrete beams, the shear strengths provided by CRAC and stirrups are statistical analyzed. The rationality of the design equations is examined by the utilization level of shear strength provided by CRAC. The maximum shear-crack widths are extracted from the test data of reinforced CRAC beams at normal service state. Comparatively, by specifying the lower limit of shear strength provided by the CRAC with various shear-span to depth ratios, China code GB50010 gives a rational method for utilizing CRAC. Under the premise that the design of shear capacity would give considerations to meet the normal serviceability, the factored strength of HRB400 rebar should be 360 MPa for the calculation of shear strength provided by stirrups. The design methods in codes of GB50010, ACI318-19 and Model Code 2010 are conservative for the shear capacity of reinforced CRAC beams.


2010 ◽  
Vol 163-167 ◽  
pp. 1460-1465
Author(s):  
Lei Yu ◽  
Yi Che ◽  
Xin Feng Zheng ◽  
Jin Xin Gong ◽  
Yu Pu Song

Seven beams were tested to investigate the effects of beam depth and longitudinal reinforcement ratio on the shear strength of reinforced concrete beams. To investigate the effects of beam depth on shear strength, beams of five different sizes were tested. Two beams were designed to investigate the shear behaviour of beams with small percentage of longitudinal reinforcement. In addition to an experimental investigation, a survey of data in the literature was performed to gain insight into the influence of beam depth and longitudinal reinforcement ratio. Based on test results and a data analysis, conclusions regarding the influence of beam depth and longitudinal reinforcement ratio on shear strength of reinforced concrete beams are presented herein.


Materials ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 837 ◽  
Author(s):  
Sun-Jin Han ◽  
Hyo-Eun Joo ◽  
Seung-Ho Choi ◽  
Inwook Heo ◽  
Kang Kim ◽  
...  

In this study, shear tests were conducted to investigate the effects of longitudinal reinforcement corrosion on the shear capacity of reinforced concrete (RC) members with transverse reinforcement. To this end, a total of eight test specimens were fabricated, and the corrosion rates and anchorage details of rebars were set as test variables. In addition, an accelerated corrosion technique was used to introduce corrosion into the longitudinal reinforcement without corroding shear reinforcement. The test results indicated that the capacities of the specimens in which tension reinforcement was not properly anchored at the ends of the members decreased rapidly at high corrosion rates, whereas the capacities of the specimens in which tension reinforcement was properly anchored by hooks were similar to or higher than those of the non-corroded specimens, despite bond loss caused by corrosion.


2014 ◽  
Vol 578-579 ◽  
pp. 164-167 ◽  
Author(s):  
Peng Li ◽  
Xian Tang Zhang ◽  
Ming Ping Wang

To investigate the influence of shear span ratio for the shear behavior of reinforced concrete beam with HRBF500 high strength rebars as stirrups, an experiment was carried out, which included 8 simply supported beams with HRBF500 rebars as stirrups. Under concentrated loads, the crack, deflection, strain of rebars, bearing capacity and failure mode are observed under different shear span ratios. Some comparisons are made between test results and calculated outcome. It shows that the shear span ratio has very important influent on the shear behavior of reinforced concrete beam with HRBF500 high strength bars as stirrups. Formula in code for design of concrete structures can be used to calculate its shear capacity with enough safety.


Sign in / Sign up

Export Citation Format

Share Document