Effect of heat flushing on the concentrations of Legionella pneumophila and other heterotrophic microbes in hot water systems of apartment buildings

1996 ◽  
Vol 42 (8) ◽  
pp. 811-818 ◽  
Author(s):  
Outi M. Zacheus ◽  
Pertti J. Martikainen

The decontamination of Legionella pneumophila and other heterotrophic microbes by heat flushing in four legionellae-positive hot water systems was studied. Before the decontamination procedure, the concentration of legionellae varied from 3.0 × 10−3 to 3.5 × 10−5 cfu/L and the hot water temperature from 43.6 to 51.5 °C. During the contamination the temperature was raised to 60–70 °C. All taps and showers were cleaned from sediments and flushed with hot water twice a day for several minutes. The decontamination lasted for 2–4 weeks. In a few weeks the heat-flushing method reduced the concentration of legionellae below the detection limit (50 cfu/L) in the hot circulating water system just before and after the heat exchanger. The high hot water temperature also decreased the viable counts of heterotrophic bacteria, fungi, and total microbial cells determined by the epifluorescent microscopy. However, the eradication of legionellae failed in a water system where the water temperature remained below 60 °C in some parts of the system. After the decontamination, the temperature of hot water was lowered to 55 °C. Thereafter, all the studied hot water systems were recolonized by legionellae within a few months, showing that the decontamination by heat flushing was temporary. Also, the contamination of other bacteria increased in a few months to the level before decontamination.Key words: legionellae, hot water system, decontamination, water temperature, heterotrophic bacteria.

2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
S Vincenti ◽  
D I La Milia ◽  
F Boninti ◽  
E Marchetti ◽  
M Wachocka ◽  
...  

Abstract The prevention of Legionella colonization of water systems is one of the goals of hospital management. Among chemical disinfection methods, chlorine dioxide (ClO2) has been largely used to control Legionella in water systems. We analysed the distribution of Legionella pneumophila serogroups (sg) and Legionella other spp before (PRE) and after (POST) installation of chlorine dioxide (ClO2) continuous disinfection systems in a Teaching Hospital in Rome. According to the Italian National Guidelines, our surveillance plan involved a systematic sampling of the water system. The sampling was performed from Jan. 2010 to Dec. 2019. From 2011 to 2019, ClO2 continuous disinfection systems were installed in all hot water system of the hospital, and maintained at a concentration of 0.25 mg/l at the end point. The isolated strains of Legionella were first serotyped using a kit that identifies sg1, other species and that discriminate sg from 2 to 15. 1505 hot water samples were collected from the Hospital and analysed. 363 samples are PRE and 1142 are POST activation of ClO2. Only the 16.74% of monitored sampling points were colonized by Legionella during the study period. This percentage decrease from 31.40% of PRE samples, to 12.08% of POST samples (p ≤ 0.000). The sg isolated were: sg3 (60.31%), sg8 (17.12%), sg1 (16.73%), sg6 (1.95%) and other species (3.89%). Comparing the distribution of sg between the PRE and POST samples, the sg8 showed a high increase (+136.84%) and the sg3 a slight decrease (-17.94%). These variations were statistically significative. The results showed a predominance of Legionella pneumophila sg3, compared to what was observed in a multicenter study conducted between different hospitals of various regions of Italy, where sg6 was the major isolate. The ClO2 affect the distribution of sg, in particular for sg8. This interesting result will be further investigated. Key messages Our data deriving from an environmental monitoring plan, show that the ClO2 affects the distribution of Legionella’s serogroups. The ClO2 reduces the percentage of samples colonized by Legionella. The ClO2 reduces the percentage of samples colonized by Legionella.


2020 ◽  
Author(s):  
Emilie Bédard ◽  
Hana Trigui ◽  
Jeffrey Liang ◽  
Margot Doberva ◽  
Kiran Paranjape ◽  
...  

AbstractIn large-building water systems, Legionella pneumophila is exposed to common environmental stressors such as copper. The aim of this study was to evaluate the susceptibility to copper of L. pneumophila isolates recovered from various sites: two clinical and seven environmental from hot water systems biofilm & water, and from cooling tower water. After one-week acclimation in simulated drinking water, strains were exposed to various copper concentrations (0.8 to 5 mg/L) for over 672 hours. Complete loss of culturability was observed for three isolates, following copper exposure to 5 mg/L for 672h. Two ST1427-like isolates were highly sensitive to copper, while the other two, isolated from biofilm samples, were resistant. The expression of the copper resistance gene copA evaluated by RT-qPCR was significantly higher for the biofilm isolates. All four ST1427-like isolates were recovered from the same water system during an outbreak. Whole genome sequencing results confirmed that the four isolates are very close phylogenetically, differing by only 29 single nucleotide polymorphisms, suggesting in situ adaptation to microenvironmental conditions, possibly due to epigenetic regulation. These results indicate that the immediate environment within a building water distribution system influences the tolerance of L. pneumophila to copper. Increased contact of L. pneumophila biofilm strains with copper piping or copper alloys in the heat exchanger might lead to local adaptation. The phenotypic differences observed between water and biofilm isolates from the hot water system of a healthcare facility warrants further investigation to assess the relevance of evaluating disinfection performances based on water sampling alone.ImportanceLegionella pneumophila is a pathogen indigenous to natural and large building water systems in the bulk and the biofilm phases. The immediate environment within a system can impact the tolerance of L. pneumophila to environmental stressors, including copper. In healthcare facilities, copper levels in water can vary, depending on water quality, plumbing materials and age. This study evaluated the impact of the isolation site (water vs biofilm, hot water system vs cooling tower) within building water systems. Closely related strains isolated from a healthcare facility hot water system exhibited variable tolerance to copper stress shown by differential expression of copA, with biofilm isolates displaying highest expression and tolerance. Relying on the detection of L. pneumophila in water samples following exposure to environmental stressor such as copper may underestimate the prevalence of L. pneumophila, leading to inappropriate risk management strategies and increasing the risk of exposure for vulnerable patients.


Pathogens ◽  
2019 ◽  
Vol 8 (1) ◽  
pp. 27 ◽  
Author(s):  
Deanna Hayes-Phillips ◽  
Richard Bentham ◽  
Kirstin Ross ◽  
Harriet Whiley

Legionnaires’ disease is a potentially fatal pneumonia like infection caused by inhalation or aspiration of water particles contaminated with pathogenic Legionella spp. Household showers have been identified as a potential source of sporadic, community-acquired Legionnaires’ disease. This study used qPCR to enumerate Legionella spp. and Legionella pneumophila in water samples collected from domestic showers across metropolitan Adelaide, South Australia. A survey was used to identify risk factors associated with contamination and to examine awareness of Legionella control in the home. The hot water temperature was also measured. A total of 74.6% (50/68) and 64.2% (43/68) showers were positive for Legionella spp. and L. pneumophila, respectively. Statistically significant associations were found between Legionella spp. concentration and maximum hot water temperature (p = 0.000), frequency of shower use (p = 0.000) and age of house (p = 0.037). Lower Legionella spp. concentrations were associated with higher hot water temperatures, showers used at least every week and houses less than 5 years old. However, examination of risk factors associated with L. pneumophila found that there were no statistically significant associations (p > 0.05) with L. pneumophila concentrations and temperature, type of hot water system, age of system, age of house or frequency of use. This study demonstrated that domestic showers were frequently colonized by Legionella spp. and L. pneumophila and should be considered a potential source of sporadic Legionnaires’ disease. Increasing hot water temperature and running showers every week to enable water sitting in pipes to be replenished by the municipal water supply were identified as strategies to reduce the risk of Legionella in showers. The lack of public awareness in this study identified the need for public health campaigns to inform vulnerable populations of the steps they can take to reduce the risk of Legionella contamination and exposure.


Author(s):  
Emilie Bédard ◽  
Hana Trigui ◽  
Jeffrey Liang ◽  
Margot Doberva ◽  
Kiran Paranjape ◽  
...  

In large-building water systems, Legionella pneumophila is exposed to common environmental stressors such as copper. The aim of this study was to evaluate the susceptibility to copper of L. pneumophila isolates recovered from various sites: two clinical and seven environmental from hot water systems biofilm & water, and from cooling tower water. After one-week acclimation in simulated drinking water, strains were exposed to various copper concentrations (0.8 to 5 mg/L) for over 672 hours. Complete loss of culturability was observed for three isolates, following copper exposure to 5 mg/L for 672h. Two ST1427-like isolates were highly sensitive to copper, while the other two, isolated from biofilm samples, maintained higher culturability. The expression of the copper resistance gene copA evaluated by RT-qPCR was significantly higher for the biofilm isolates. All four ST1427-like isolates were recovered from the same water system during an outbreak. Whole genome sequencing results confirmed that the four isolates are very close phylogenetically, differing by only 29 single nucleotide polymorphisms, suggesting in situ adaptation to microenvironmental conditions, possibly due to epigenetic regulation. These results indicate that the immediate environment within a building water distribution system influences the tolerance of L. pneumophila to copper. Increased contact of L. pneumophila biofilm strains with copper piping or copper alloys in the heat exchanger might lead to local adaptation. The phenotypic differences observed between water and biofilm isolates from the hot water system of a healthcare facility warrants further investigation to assess the relevance of evaluating disinfection performances based on water sampling alone. Importance Legionella pneumophila is a pathogen indigenous to natural and large building water systems in the bulk and the biofilm phases. The immediate environment within a system can impact the tolerance of L. pneumophila to environmental stressors, including copper. In healthcare facilities, copper levels in water can vary, depending on water quality, plumbing materials and age. This study evaluated the impact of the isolation site (water vs biofilm, hot water system vs cooling tower) within building water systems. Closely related strains isolated from a healthcare facility hot water system exhibited variable tolerance to copper stress shown by differential expression of copA, with biofilm isolates displaying highest expression and tolerance. Relying on the detection of L. pneumophila in water samples following exposure to environmental stressor such as copper may underestimate the prevalence of L. pneumophila, leading to inappropriate risk management strategies and increasing the risk of exposure for vulnerable patients.


1997 ◽  
Vol 43 (12) ◽  
pp. 1189-1196 ◽  
Author(s):  
Carmen Moreno ◽  
Isabel de Blas ◽  
Francisca Miralles ◽  
David Apraiz ◽  
Vicente Catalan

In this paper we describe a simple method, noncorrosive to pipes, for the eradication of Legionella pneumophila from potable water systems. This method is based on the systematic purging of the pipe networks with cold water containing 1 – 1.5 mg residual chlorine/L. In the hot water system, a new pipe bypassing the water heater was installed, whereas in the air conditioning system, the circuit is purged with water from the tap water system. The feasibility of this method was studied in two hotels in which the presence of Legionella was detected despite treatment of the water by the hyperchlorination method. The evolution of the presence of Legionella was studied by culture and polymerase chain reaction. Eighty samples from hotel A and sixty-seven samples from hotel B were analyzed during the time that the eradication method was applied. Our results showed that this method permitted the effective elimination of L. pneumophila after 5 months in hotel A and 7 months in hotel B.Key words: Legionella pneumophila, eradication.


2021 ◽  
Vol 676 (1) ◽  
pp. 012099
Author(s):  
Yao Yang ◽  
Xiaona Li ◽  
Xiang Li ◽  
Yuchao Li ◽  
Tianqi Meng ◽  
...  

1969 ◽  
Vol 46 (4) ◽  
pp. 272-283
Author(s):  
William Pennock ◽  
Gilberto Maldonado

1. Anthracnose damage was greatly reduced in mango fruit picked at shipping maturity and immersed in hot water before storage and subsequent ripening. 2. The equipment and method of treating the fruits are described and discussed. 3. A precise technique which was devised for measuring anthracnose damage before and after storage is also described. 4. Immersion of the fruit for 15 minutes in water held at temperatures between 51° C. and 51.5° C., with a safety margin of 0.5° C., is recommended for commercial practice before packing and shipment. Water temperature must be kept below 52° C. to prevent possible scalding of the fruit.