A simple method for the eradication ofLegionella pneumophilafrom potable water systems

1997 ◽  
Vol 43 (12) ◽  
pp. 1189-1196 ◽  
Author(s):  
Carmen Moreno ◽  
Isabel de Blas ◽  
Francisca Miralles ◽  
David Apraiz ◽  
Vicente Catalan

In this paper we describe a simple method, noncorrosive to pipes, for the eradication of Legionella pneumophila from potable water systems. This method is based on the systematic purging of the pipe networks with cold water containing 1 – 1.5 mg residual chlorine/L. In the hot water system, a new pipe bypassing the water heater was installed, whereas in the air conditioning system, the circuit is purged with water from the tap water system. The feasibility of this method was studied in two hotels in which the presence of Legionella was detected despite treatment of the water by the hyperchlorination method. The evolution of the presence of Legionella was studied by culture and polymerase chain reaction. Eighty samples from hotel A and sixty-seven samples from hotel B were analyzed during the time that the eradication method was applied. Our results showed that this method permitted the effective elimination of L. pneumophila after 5 months in hotel A and 7 months in hotel B.Key words: Legionella pneumophila, eradication.

1996 ◽  
Vol 42 (8) ◽  
pp. 811-818 ◽  
Author(s):  
Outi M. Zacheus ◽  
Pertti J. Martikainen

The decontamination of Legionella pneumophila and other heterotrophic microbes by heat flushing in four legionellae-positive hot water systems was studied. Before the decontamination procedure, the concentration of legionellae varied from 3.0 × 10−3 to 3.5 × 10−5 cfu/L and the hot water temperature from 43.6 to 51.5 °C. During the contamination the temperature was raised to 60–70 °C. All taps and showers were cleaned from sediments and flushed with hot water twice a day for several minutes. The decontamination lasted for 2–4 weeks. In a few weeks the heat-flushing method reduced the concentration of legionellae below the detection limit (50 cfu/L) in the hot circulating water system just before and after the heat exchanger. The high hot water temperature also decreased the viable counts of heterotrophic bacteria, fungi, and total microbial cells determined by the epifluorescent microscopy. However, the eradication of legionellae failed in a water system where the water temperature remained below 60 °C in some parts of the system. After the decontamination, the temperature of hot water was lowered to 55 °C. Thereafter, all the studied hot water systems were recolonized by legionellae within a few months, showing that the decontamination by heat flushing was temporary. Also, the contamination of other bacteria increased in a few months to the level before decontamination.Key words: legionellae, hot water system, decontamination, water temperature, heterotrophic bacteria.


2013 ◽  
Vol 6 (2) ◽  
pp. 99-114 ◽  
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing Dutch guidelines for the design of the drinking water and hot water system of non-residential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2006 ◽  
Vol 72 (1) ◽  
pp. 378-383 ◽  
Author(s):  
Matthew R. Moore ◽  
Marsha Pryor ◽  
Barry Fields ◽  
Claressa Lucas ◽  
Maureen Phelan ◽  
...  

ABSTRACT Legionnaires' disease (LD) outbreaks are often traced to colonized potable water systems. We collected water samples from potable water systems of 96 buildings in Pinellas County, Florida, between January and April 2002, during a time when chlorine was the primary residual disinfectant, and from the same buildings between June and September 2002, immediately after monochloramine was introduced into the municipal water system. Samples were cultured for legionellae and amoebae using standard methods. We determined predictors of Legionella colonization of individual buildings and of individual sampling sites. During the chlorine phase, 19 (19.8%) buildings were colonized with legionellae in at least one sampling site. During the monochloramine phase, six (6.2%) buildings were colonized. In the chlorine phase, predictors of Legionella colonization included water source (source B compared to all others, adjusted odds ratio [aOR], 6.7; 95% confidence interval [CI], 2.0 to 23) and the presence of a system with continuously circulating hot water (aOR, 9.8; 95% CI, 1.9 to 51). In the monochloramine phase, there were no predictors of individual building colonization, although we observed a trend toward greater effectiveness of monochloramine in hotels and single-family homes than in county government buildings. The presence of amoebae predicted Legionella colonization at individual sampling sites in both phases (OR ranged from 15 to 46, depending on the phase and sampling site). The routine introduction of monochloramine into a municipal drinking water system appears to have reduced colonization by Legionella spp. in buildings served by the system. Monochloramine may hold promise as community-wide intervention for the prevention of LD.


2021 ◽  
Vol 59 (3) ◽  
Author(s):  
Daniela Glažar Ivče ◽  
Dobrica Rončević ◽  
Marina Šantić ◽  
Arijana Cenov ◽  
Dijana Tomić Linšak ◽  
...  

Research background. Legionella are Gram-negative bacteria that are ubiquitous in the natural environment. Contaminated water in manmade water systems is a potential source of transmission of Legionnaires’ disease (LD). The aim of this study was to explore the prevalence of Legionella pneumophila (L. pneumophila) in the drinking water distribution system (DWDS) of Primorje-Gorski Kotar County (PGK County), Croatia, for the period 2013-2019, coupled with the incidence of LD. A number of L. pneumophila-positive samples (>100 CFU/L), serogroup distribution, and the degree of contamination of specific facilities (health & aged care, tourism, sports) were assessed. Based on the results obtained, the reasoning for the implementation of a mandatory Legionella environmental surveillance program was assessed. Experimental approach. Sample testing for Legionella was carried out according to ISO 1173. A Heterotrophic Plate Count (HPC) and P. aeruginosa were analysed along with the basic physico-chemical indicators of drinking water quality. The research period was divided into two parts, namely, the 2013-2018 period (before implementation of the prevention program, after the outbreak of LD), and year 2019 (proactive approach, no LD cases recorded). Results and conclusion. During the 7-year observation period in PGK County, an increase in the number of samples tested for Legionella was found. An increase in Legionella-positive samples (particularly pronounced during the warmer part of the year) was recorded, along with a growing trend in the number of reported LD cases. In addition to hot water systems, the risk of Legionella colonization also applies to cold water systems. Health & aged care facilities appear to be at highest risk. In addition to the higher proportion of positive samples and a higher degree of microbiological load at these facilities, the highest proportion of L. pneumophila SGs 2-14 was identified. Due to the diagnostic limitations of the applied tests, the number of LD cases is underdiagnosed. Novelty and scientific contribution. The introduction of a mandatory preventive approach to monitoring Legionella in DWDS water samples, along with the definition of national criteria for the interpretation of results, will create the preconditions for diagnosis and adequate treatment of larger numbers of LD cases.


2019 ◽  
Vol 116 ◽  
pp. 00106 ◽  
Author(s):  
Miroslaw Zukowski

In the present work, results of experimental research on the mains water temperature supplying the Solar Domestic Hot Water system in the period from 2016 to 2018 are shown. The test object is located in the Hotel for Research Assistants on Bialystok University of Technology campus in Poland. One of the elements that will guarantee the correct energy balance of a hot tap-water system is the exact determination of the cold water temperature. The aim of this study is estimation of the temperature of the mains water flowing into the district heating substation and the water feeding directly the heat storage tanks. The research results showed that the average value of the cold water was 14.09°C during the 3 years of measurements. Moreover, it was shown that this temperature increased by about 0.4°C as a result of heat exchange with the air inside the substation. In the article, the author proposed modifications of coefficients in a commonly used model developed by National Renewable Energy Laboratory for determining the temperature of mains water in energy simulations. The proposed changes allow for accurate modelling of the cold water temperature under the climate conditions of north-eastern Poland.


2004 ◽  
Vol 70 (3) ◽  
pp. 1651-1657 ◽  
Author(s):  
Helena Aurell ◽  
Philippe Catala ◽  
Pierre Farge ◽  
France Wallet ◽  
Matthieu Le Brun ◽  
...  

ABSTRACT A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.


2012 ◽  
Vol 5 (1) ◽  
pp. 455-471
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing guidelines related to the water demand of non-residential buildings are outdated and do not cover hot water demand for the appropriate selection of hot water devices. Moreover, they generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM® to derive design rules for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, i.e. offices, hotels and nursing homes. In this paper, the design rules are validated with measurements of cold and hot water patterns on a per second base. The good correlation between the simulated patterns and the measured patterns indicates that the basis of the design rules, the SIMDEUM simulated standardised buildings, is solid. Moreover, the SIMDEUM based rules give a better prediction of the measured peak values for cold water flow than the existing guidelines. Furthermore, the new design rules can predict hot water use well. In this paper it is illustrated that the new design rules lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
S Vincenti ◽  
D I La Milia ◽  
F Boninti ◽  
E Marchetti ◽  
M Wachocka ◽  
...  

Abstract The prevention of Legionella colonization of water systems is one of the goals of hospital management. Among chemical disinfection methods, chlorine dioxide (ClO2) has been largely used to control Legionella in water systems. We analysed the distribution of Legionella pneumophila serogroups (sg) and Legionella other spp before (PRE) and after (POST) installation of chlorine dioxide (ClO2) continuous disinfection systems in a Teaching Hospital in Rome. According to the Italian National Guidelines, our surveillance plan involved a systematic sampling of the water system. The sampling was performed from Jan. 2010 to Dec. 2019. From 2011 to 2019, ClO2 continuous disinfection systems were installed in all hot water system of the hospital, and maintained at a concentration of 0.25 mg/l at the end point. The isolated strains of Legionella were first serotyped using a kit that identifies sg1, other species and that discriminate sg from 2 to 15. 1505 hot water samples were collected from the Hospital and analysed. 363 samples are PRE and 1142 are POST activation of ClO2. Only the 16.74% of monitored sampling points were colonized by Legionella during the study period. This percentage decrease from 31.40% of PRE samples, to 12.08% of POST samples (p ≤ 0.000). The sg isolated were: sg3 (60.31%), sg8 (17.12%), sg1 (16.73%), sg6 (1.95%) and other species (3.89%). Comparing the distribution of sg between the PRE and POST samples, the sg8 showed a high increase (+136.84%) and the sg3 a slight decrease (-17.94%). These variations were statistically significative. The results showed a predominance of Legionella pneumophila sg3, compared to what was observed in a multicenter study conducted between different hospitals of various regions of Italy, where sg6 was the major isolate. The ClO2 affect the distribution of sg, in particular for sg8. This interesting result will be further investigated. Key messages Our data deriving from an environmental monitoring plan, show that the ClO2 affects the distribution of Legionella’s serogroups. The ClO2 reduces the percentage of samples colonized by Legionella. The ClO2 reduces the percentage of samples colonized by Legionella.


Author(s):  
Antonios Papadakis ◽  
Maria Keramarou ◽  
Dimosthenis Chochlakis ◽  
Vassilios Sandalakis ◽  
Varvara Mouchtouri ◽  
...  

Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease and cases, clusters or outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ Disease Surveillance Network, were inspected and tested for Legionella spp. during 2000–2019 by the public health authorities of the island of Crete (Greece). A total of 3,311 samples were collected: 1,885 (56.93%) from cold water supply systems, 1,387 (41.89%) from hot water supply systems, 37 (1.12%) were swab samples and two (0.06%) were soil. Of those, 685 (20.69%), were collected from 83 (62.89%) hotels, testing positive (≥ 50CFU/L) for Legionella pneumophila) serogroups 1-10, 12-14 and non-pneumophila species (L. anisa, L. erythra, L. tusconensis, L. taurinensis, L. birminghamensis, L. rubrilucens, L. londiniesis, L. oakridgensis, L. santicrusis, L. brunensis, L. maceacherii). The most frequently isolated L. pneumophila serogroups were 1 (27.92%) and 3 (17.08%). Significantly higher isolation rates were obtained from hot water supply systems (25.96%) versus cold water systems (16.98%) and swab samples (13.51%). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for hot water temperature <55 °C (R.R.: 4.43), chlorine concentrations <0.2 mg/L (R.R.: 2.69), star rating <4 (R.R.: 1.73) and absence of Water Safety Plan implementation (R.R.: 1.57).


Sign in / Sign up

Export Citation Format

Share Document