INFLUENCE OF WINDOW EFFECT OF SEMICONDUCTOR X-RAY DETECTORS ON THE RESPONSE FUNCTION AND DETECTION EFFICIENCY

1992 ◽  
Vol 02 (03) ◽  
pp. 255-262
Author(s):  
K. SHIMA

In order to search the dead layer of a Si(Li) x-ray detector, the jump ratio of the detection efficiency observed at the Si-K-edge energy was precisely measured by changing the incident photon energies at around 1.84 keV by using monoenergetic photons provided by SOR. Here, the dead layer is meant to be the Si region where the charge collection efficiency, η, is zero. As the result, the dead layers for two detectors investigated at present turned out to be absent. On the other hand, the Si front layers in which the charge collection is incomplete (0<η<1) were estimated to be 0.26 µm and 0.17 µm from a simple analysis for low energy tail spectrum. From these results, the effect of detector window on the response function and detection efficiency is discussed.

2016 ◽  
Vol 59 (2) ◽  
pp. 295-300
Author(s):  
A. N. Zarubin ◽  
I. I. Kolesnikova ◽  
A. D. Lozinskaya ◽  
V. A. Novikov ◽  
M. S. Skakunov ◽  
...  

1993 ◽  
Vol 302 ◽  
Author(s):  
W. Bencivelli ◽  
E. Bertolucci ◽  
U. Bottigli ◽  
A. Cavallini ◽  
S. D'Auria ◽  
...  

ABSTRACTGallium Arsenide crystals are among the most efficient detectors of X-rays at room temperature. Different GaAs crystals have been irradiated with photons from radioactive sources, to compare their response in view of a possible application for Digital Radiology. The detectors have been obtained by various manufacturers and with different techniques (LEC and LPE crystals). Experimental results include I-V curves, charge collection efficiency and detection efficiency as a function of bias. A comparison is made with a simulation program.


2020 ◽  
Vol 127 (8) ◽  
pp. 084502 ◽  
Author(s):  
S. O. Kasap ◽  
J. Yang ◽  
B. Simonson ◽  
E. Adeagbo ◽  
M. Walornyj ◽  
...  

2002 ◽  
Vol 16 (06n07) ◽  
pp. 1018-1023 ◽  
Author(s):  
J. AHN ◽  
B. GAN ◽  
Q. ZHANG ◽  
S. F. YOON ◽  
V. LIGATCHEV ◽  
...  

The CVD diamond UV photodetector shows more than four orders of photoresponsivity discrimination between UV and visible light. Post-treatment on as-fabricated photodetector is essential for a good response to UV light and blindness to visible light. The CVD diamond X-ray detector shows linear dependence of photocurrent on X-ray intensity and high response speed. The mapping of charge collection efficiency on the whole sensing area of a CVD diamond alpha particle detector has been obtained using ion-beam-induced charge microscopy technique. Three peaks have been observed in the charge collection spectrum.


Sign in / Sign up

Export Citation Format

Share Document