scholarly journals Rapid determination of tannin in Danshen and Guanxinning injections using UV spectrophotometry for quality control

2018 ◽  
Vol 11 (06) ◽  
pp. 1850034
Author(s):  
Hongxia Huang ◽  
Yuanyuan Lv ◽  
Xiaoyi Sun ◽  
Shuangshuang Fu ◽  
Xuefang Lou ◽  
...  

A technique for the determination of tannin content in traditional Chinese medicine injections (TCMI) was developed based on ultraviolet (UV) spectroscopy. Chemometrics were used to construct a mathematical model of absorption spectrum and tannin reference content of Danshen and Guanxinning injections, and the model was verified and applied. The results showed that the established UV-based spectral partial least squares regression (PLS) tannin content model performed well with a correlation coefficient ([Formula: see text]) of 0.952, root mean square error of calibration (RMSEC) of 0.476[Formula: see text][Formula: see text]g/ml, root mean square error of validation (RMSEV) of 1.171[Formula: see text][Formula: see text]g/ml, and root mean square error of prediction (RMSEP) of 0.465[Formula: see text][Formula: see text]g/ml. Pattern recognition models using linear discriminant analysis (LDA) and [Formula: see text] nearest neighbor ([Formula: see text]-NN) classifiers based on UV spectrum could successfully classify different types of injections and different manufacturers. The established method to measure tannin content based on UV spectroscopy is simple, rapid and reliable and provides technical support for quality control of tannin in Chinese medicine injections.

2013 ◽  
Vol 807-809 ◽  
pp. 1978-1983 ◽  
Author(s):  
Cai Xia Xie ◽  
Hai Yan Gong ◽  
Jian Ying Liu ◽  
Jing Wei Lei ◽  
Xiao Yan Duan ◽  
...  

To establish a rapid analytical method for Loganin in Qiju Dihuang Pills (condensed) by Near-infrared Diffuse Reflectance Technique. Collecting NIR spectra by NIR Diffuse Reflectance Spectroscopy, the partial least square calibration model was built. The correlation coefficients (R2) and the root-mean-square error of cross-validation (RMSECV) were 0.99764 and 0.09340, respectively. In the external validation,coefficients of determination (r2) between NIRS and HPLC values was 0.97348,the root-mean-square error of prediction (RMSEP) was 0.08491. The results showed that the method was rapid, accurate, and could be applied to the fast determination of Loganin in Qiju Dihuang Pills (condensed).


2020 ◽  
Vol 103 (1) ◽  
pp. 257-264 ◽  
Author(s):  
Ali M Yehia ◽  
Heba T Elbalkiny ◽  
Safa’a M Riad ◽  
Yasser S Elsaharty

Abstract Background: Chemometrics is a discipline that allows the spectral resolution of drugs in a complicated matrix (e.g., environmental water samples) as an alternative to chromatographic methods. Objective: Three analgesics were traced in wastewater samples with simple and cost-effective multivariate approaches using spectrophotometric data. Methods and Results: Four chemometric approaches were applied for the simultaneous determination of diclofenac, paracetamol, and ibuprofen. Partial least squares (PLS), principal component regression (PCR), artificial neural networks (ANN), and multivariate curve resolution (MCR)–alternating least squares (ALS) were selected. The presented methods were compared and validated for their qualitative and quantitative analyses. Moreover, statistical comparison between the results obtained by the proposed methods and the official methods showed no significant differences. Conclusions: The proposed multivariate calibrations were accurate and specific for quantitative analysis of the studied components. MCR-ALS is the only method that has the capacity for both the quantitative and qualitative analysis of the studied drugs. Highlights: Four chemometric approaches were used for analysis of severally overlapped ternary mixture of three analgesics. The analytical performance of PCR, PLS, MCR-ALS, and ANN was compared and validated in terms of root mean square error of calibration (RMSEC), SE of prediction, and recoveries. ANN gave the highest predicted concentrations with the lowest RMSEC and root mean square error of prediction. MCR-ALS has the capacity for both qualitative and quantitative measurement. The methods have been effectively applied for real samples and compared to official methods.


Author(s):  
T.Yu. Galushina ◽  
◽  
O.N. Letner ◽  
O.M. Syusina ◽  
◽  
...  

The paper presents the results of assessment definition precision of the Yarkovsky effect parameter A 2 for asteroids with small perihelion distances, known on epoch January 2021. It is shown that the observation interval has a significant effect on the precision of A 2. As the interval increases, the root mean square error of the parameter decreases. For asteroids (3200) Phaethon and (137924) 2000 BD19 with a large observation interval, an experiment was carried out to reduce the number of real observations. A decrease of the interval and number of observations leads to a loss in the precision of the parameter being determined. Modeling observations based on real ones with an increase in their precision showed that the root mean square error of the A 2 parameter decreases in proportion to the increase in the observation precision. The increase of interval due to model observations confirmed the conclusion about the inverse dependence of the A 2 uncertainty from number and interval of observations.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6438
Author(s):  
Marie Sejkorová ◽  
Branislav Šarkan ◽  
Petr Veselík ◽  
Ivana Hurtová

The TBN (Total Base Number) parameter is generally recognized by both engine oil processors and engine manufacturers as a key factor of oil quality. This is especially true for lubricating oils used in diesel and gas engines, which are exposed to relatively high temperatures and, therefore, require more effective protection against degradation. The FTIR spectrometry method together with a multivariate statistical software helped to create a model for the determination of TBN of worn motor oil SAE 15W-40 ACEA: E5/E7, API: CI-4. The best results were provided using a model FTIR with Partial Least Squares (PLS) regression in an overall range of 4000–650 cm−1 without the use of mathematical adjustments of the scanned spectra by derivation. Individual spectral information was condensed into nine principal components with linear combinations of the original absorbances at given wavenumbers that are mutually not correlated. A correlation coefficient (R) between values of TBN predicted by the FTIR-PLS model and values determined using a potentiometric titration in line with the ČSN ISO 3771 standard reached a value of 0.93. The Root Mean Square Error of Calibration (RMSEC) was determined to be 0.171 mg KOH.g−1, and the Root Mean Square Error of Prediction (RMSEP) was determined to be 0.140 mg KOH.g−1. The main advantage of the proposed FTIR-PLS model can be seen in a rapid determination and elimination of the necessity to work with dangerous chemicals. FTIR-PLS is used mainly in areas of oil analysis where the speed of analysis is often more important than high accuracy.


2015 ◽  
Vol 29 (3) ◽  
pp. 275-282 ◽  
Author(s):  
Konrád Deák ◽  
Tamás Szigedi ◽  
Zoltán Pék ◽  
Piotr Baranowski ◽  
Lajos Helyes

AbstractA rapid non-destructive method for profiling tomato carotenoids was developed using NIR spectrometry. One hundred and twenty tomato samples were produced at the Experimental Farm of Szent István University in Gödöllő (Hungary). The sample preparation was based on homogenization. The mixed samples were scanned with a diode array Perten DA7200 NIR Analyzer (950-1650 nm) and analyzed by high performance liquid chromatography. The calibration was based on partial least squares regression with cross-validation. The performance of the final model was evaluated according to root mean square error of cross-validation. The results indicate that the main carotenoid components were accurately predicted. The correlation between the NIR measurement and the β-carotene content of tomatoes was adequately high [R2CV = 0.89; root mean square error of cross-validation = 0.174 μg g−1]. The NIR method was also performed for the determination of the all-trans lycopene content (R2CV = 0.75; root mean square error of cross-validation = 6.88 μg g−1). It can be concluded that the diode array NIR spectrometer has the potential to be used for the determination of the main carotenoids of tomatoes.


2020 ◽  
Vol 103 (2) ◽  
pp. 504-512
Author(s):  
Yijuan Hu ◽  
Hongjian Zhang ◽  
Weiqing Liang ◽  
Pan Xu ◽  
Kelang Lou ◽  
...  

Abstract Background: Peucedani Radix is a popular traditional Chinese medicine herb with a long history in China. Praeruptorin A (PA), praeruptorin B (PB), and praeruptorin E (PE) are usually taken as important quality indexes of Peucedani Radix. Objective: To establish a rapid method for simultaneous determination of PA, PB, PE, and moisture contents in Peucedani Radix using near-infrared (NIR) spectroscopy and chemometrics. Methods: One hundred twenty Peucedani Radix samples were analyzed with HPLC as a reference method. The NIR spectral scanning range was from 12000 cm−1 to 4000 cm−1. Partial least squares (PLS) regression algorithm was used to establish calibration models. Three variable selection methods were investigated, including variable importance in projection (VIP), competitive adaptive reweighted sampling (CARS), and Monte Carlo uninformative variable elimination (MCUVE). The performances of the established models were evaluated by root-mean-square error (RMSEC) and determination coefficient (Rc2) of calibration set, root-mean-square error (RMSEP) and determination coefficient (Rp2) of prediction set, and residual predictive deviation (RPD). Results: A clear ranking of the performance of the calibration models could be as follows: CARS-PLS > MCUVE-PLS > VIP-PLS > Full-PLS. For CARS-PLS, Rp2, RMSEP, and RPD of the prediction set are as follows: 0.9204, 0.0860%, and 3.5850 for PA; 0.8011, 0.0431%, and 2.0868 for PB; 0.8043, 0.0367%, and 2.1569 for PE; and 0.9249, 0.3350%, and 3.6551 for moisture, respectively. Conclusions: The NIR spectroscopy combined with CARS-PLS calibration models could be used for rapid and accurate determination of PA, PB, PE, and moisture contents in Peucedani Radix samples.


2009 ◽  
Vol 92 (1) ◽  
pp. 248-256
Author(s):  
Aamna Balouch ◽  
Najma Memon ◽  
Muhammad I Bhanger ◽  
Muhammad Y Khuhawar

Abstract Partial least-squares regression was applied for the simultaneous determination of iron, vanadium, and cobalt after complexation with picolinaldehyde-4-phenyl-3-thiosemicarbazone (PAPT) in the presence of anionic sodium dodecylsulfate (SDS) micelles. These 3 complexed metal ions exhibited overlapping spectra in the 390510 nm region with a maximum absorbance at 415 nm at pH 3.0 and enhanced absorbance in the presence of SDS. The data for the simultaneous determination of these metal ions were analyzed using a simple partial least-squares (SIMPLS) algorithm. Formation constants (log Kf) were found to be 4.65, 3.29, and 4.85 for PAPT complexes of Fe, V, and Co, respectively, and the detection limits for Fe, V, and Co were 0.013, 0.002, and 0.010 g/mL, respectively. Common anions and cations did not interfere with the proposed method. The method was validated by calculating root mean square error of cross-validation, root mean square error of calibration, and root mean square error of prediction and was applied to determine these 3 metal ions in real crude oil samples.


2013 ◽  
Vol 807-809 ◽  
pp. 1972-1977
Author(s):  
Yan Bai ◽  
Hai Yan Gong ◽  
Xiao Qing Li ◽  
Cai Xia Xie ◽  
Xiao Yan Duan ◽  
...  

The objective of the present research was to establish a rapid analytical method for paeoniflorin and moisture in Xiaoyao Pills (condensed) by near-infrared spectroscopy. The near-infrared spectral data of 97 samples was collected by Nicolet 6700 NIR spectrograph,and the reference value of index component content were obtained by HPLC and oven-drying method. Then the multivariate calibration model of paeoniflorin and moisture were established by patrical least square (PLS) and predicting the content of unknow samples. The results showed that the correlation coefficients (R2) of the quantitative calibration model for paeoniflorin and moisture were 0.99774,0.95352, the root-mean-square error of calibration (RMSEC) were 0.00489,0.132,the root-mean-square error of prediction (RMSEP) were 0.00827,0.177. The results indicated that NIRS can provide a simple and accurate way for the fast determination of index component in large numbers of Xiaoyao Pills (concentrated).


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Weihao Zhu ◽  
Hao Hong ◽  
Zhihui Hong ◽  
Xianjie Kang ◽  
Weifeng Du ◽  
...  

In order to identify the quality of crude and processed Corydalis Rhizoma decoction pieces, the research established a simple, fast, reliable, and validated near-infrared qualitative and quantitative model combined with chemometrics. 51 batches of crude and 40 batches of processed Corydalis Rhizoma from the Zhejiang and Jiangsu provinces of China were collected and analyzed. Crude and processed Corydalis Rhizoma samples were crushed to obtain NIR spectra. The content of seven alkaloids in crude and processed Corydalis Rhizoma was determined by high-performance liquid chromatography (HPLC). Pretreatment methods were screened such as normalization methods, offset filtering methods, and smoothing. Combined with partial least squares-discriminant analysis (PLS-DA) and partial least squares (PLS), the qualitative and quantitative models of crude and processed Corydalis Rhizoma were established, and the correlation coefficient (R2), root mean square error of calibration (RMSEC), and root mean square error of prediction (RMSEP) were used as evaluation indexes. Tetrahydropalmatine was used as an example for screening pretreatment methods; the results showed that MSC combined with the second derivative and no smoothing and the model with the wavelength range of 10000–5000 cm−1 had the best predictive ability and applied to all seven alkaloid components. Among them, the correlation coefficients were all higher than 0.99, and RMSEC and RMSEP were all less than 1%. The qualitative and quantitative model of the seven alkaloids in Corydalis Rhizoma can effectively identify the crude and processed Corydalis Rhizoma and determine the content of the seven alkaloids. By studying the NIR qualitative and quantitative models of crude and processed Corydalis Rhizoma, we can achieve rapid discrimination and quantitative prediction of crude and processed Corydalis Rhizoma. These methods can greatly improve the efficiency of traditional Chinese medicine analysis and provide a strong scientific basis for the quality identification and control of traditional Chinese medicine.


2021 ◽  
Vol 4 (2) ◽  
pp. 67
Author(s):  
Etik Zukhronah ◽  
Winita Sulandari ◽  
Isnandar Slamet ◽  
Sugiyanto Sugiyanto ◽  
Irwan Susanto

<p><strong>Abstract.</strong> Grojogan Sewu visitors experience a significant increase during school holidays, year-end holidays, and also Eid al-Fitr holidays. The determination of Eid Al-Fitr uses the Hijriyah calendar so that the occurrence of Eid al-Fitr will progress 10 days when viewed from the Gregorian calendar, this causes calendar variations. The objective of this paper is to apply a calendar variation model based on time series regression and SARIMA models for forecasting the number of visitors in Grojogan Sewu. The data are Grojogan Sewu visitors from January 2009 until December 2019. The results show that time series regression with calendar variation yields a better forecast compared to the SARIMA model. It can be seen from the value of  root mean square error (<em>RMSE</em>) out-sample of time series regression with calendar variation is less than of SARIMA model.</p><p><strong>Keywords: </strong>Calendar variation, time series regression, SARIMA, Grojogan Sewu</p>


Sign in / Sign up

Export Citation Format

Share Document