Forearm cutaneous vascular and sudomotor responses to whole body passive heat stress in young smokers

2015 ◽  
Vol 309 (1) ◽  
pp. R36-R42 ◽  
Author(s):  
Nicole E. Moyen ◽  
Hannah M. Anderson ◽  
Jenna M. Burchfield ◽  
Matthew A. Tucker ◽  
Melina A. Gonzalez ◽  
...  

The purpose of this study was to compare smokers and nonsmokers' sudomotor and cutaneous vascular responses to whole body passive heat stress. Nine regularly smoking (SMK: 29 ± 9 yr; 10 ± 6 cigarettes/day) and 13 nonsmoking (N-SMK: 27 ± 8 yr) males were passively heated until core temperature (TC) increased 1.5°C from baseline. Forearm local sweat rate (LSR) via ventilated capsule, sweat gland activation (SGA), sweat gland output (SGO), and cutaneous vasomotor activity via laser-Doppler flowmetry (CVC) were measured as mean body temperature increased (ΔTb) during passive heating using a water-perfused suit. Compared with N-SMK, SMK had a smaller ΔTb at the onset of sweating (0.52 ± 0.19 vs. 0.35 ± 0.14°C, respectively; P = 0.03) and cutaneous vasodilation (0.61 ± 0.21 vs. 0.31 ± 0.12°C, respectively; P < 0.01). Increases in LSR and CVC per °C ΔTb (i.e., sensitivity) were similar in N-SMK and SMK (LSR: 0.63 ± 0.21 vs. 0.60 ± 0.40 Δmg/cm2/min/°C ΔTb, respectively, P = 0.81; CVC: 82.5 ± 46.2 vs. 58.9 ± 23.3 Δ%max/°C ΔTb, respectively; P = 0.19). However, the plateau in LSR during whole body heating was higher in N-SMK vs. SMK (1.00 ± 0.13 vs. 0.79 ± 0.26 mg·cm−2·min−1; P = 0.03), which was likely a result of higher SGO (8.94 ± 3.99 vs. 5.94 ± 3.49 μg·gland−1·min−1, respectively; P = 0.08) and not number of SGA (104 ± 7 vs. 121 ± 9 glands/cm2, respectively; P = 0.58). During whole body passive heat stress, smokers had an earlier onset for forearm sweating and cutaneous vasodilation, but a lower local sweat rate that was likely due to lower sweat output per gland. These data provide insight into local (i.e., forearm) thermoregulatory responses of young smokers during uncompensatory whole body passive heat stress.

2015 ◽  
Vol 309 (5) ◽  
pp. R623-R627 ◽  
Author(s):  
Jonathan E. Wingo ◽  
David A. Low ◽  
David M. Keller ◽  
Kenichi Kimura ◽  
Craig G. Crandall

The influence of thermoreceptors in human facial skin on thermoeffector responses is equivocal; furthermore, the presence of thermoreceptors in the respiratory tract and their involvement in thermal homeostasis has not been elucidated. This study tested the hypothesis that hot air directed on the face and inhaled during whole body passive heat stress elicits an earlier onset and greater sensitivity of cutaneous vasodilation and sweating than that directed on an equal skin surface area away from the face. Six men and two women completed two trials separated by ∼1 wk. Participants were passively heated (water-perfused suit; core temperature increase ∼0.9°C) while hot air was directed on either the face or on the lower leg (counterbalanced). Skin blood flux (laser-Doppler flowmetry) and local sweat rate (capacitance hygrometry) were measured at the chest and one forearm. During hot-air heating, local temperatures of the cheek and leg were 38.4 ± 0.8°C and 38.8 ± 0.6°C, respectively ( P = 0.18). Breathing hot air combined with facial heating did not affect mean body temperature onsets ( P = 0.97 and 0.27 for arm and chest sites, respectively) or slopes of cutaneous vasodilation ( P = 0.49 and 0.43 for arm and chest sites, respectively), or the onsets ( P = 0.89 and 0.94 for arm and chest sites, respectively), or slopes of sweating ( P = 0.48 and 0.65 for arm and chest sites, respectively). Based on these findings, respiratory tract thermoreceptors, if present in humans, and selective facial skin heating do not modulate thermoeffector responses during passive heat stress.


2017 ◽  
Vol 312 (5) ◽  
pp. R637-R642 ◽  
Author(s):  
Matthew A. Tucker ◽  
Ashley Six ◽  
Nicole E. Moyen ◽  
Alf Z. Satterfield ◽  
Matthew S. Ganio

Hypohydration decreases cutaneous vasodilation and sweating during heat stress, but it is unknown if these decrements are from postsynaptic (i.e., sweat gland/blood vessel) alterations. The purpose of this study was to determine if hypohydration affects postsynaptic cutaneous vasodilation and sweating responses. Twelve healthy men participated in euhydrated (EU) and hypohydrated (HY) trials, with hypohydration induced via fluid restriction and passive heat stress. Changes in cutaneous vascular conductance (CVC; %max) in response to incremental intradermal infusion of the endothelium-independent vasodilator sodium nitroprusside (SNP) and the endothelium-dependent vasodilator methacholine chloride (MCh) were assessed by laser Doppler flowmetry. Local sweat rate (LSR) was simultaneously assessed at the MCh site via ventilated capsule. At the end of the last dose, maximal CVC was elicited by delivering a maximal dose of SNP (5 × 10−2 M) for 30 min to both sites with simultaneous local heating (~44°C) at the SNP site. The concentration of drug needed to elicit 50% of the maximal response (log EC50) was compared between hydration conditions. The percent body mass loss was greater with HY vs. EU (−2.2 ± 0.7 vs. −0.1 ± 0.7%, P < 0.001). Log EC50 of endothelium-dependent CVC was lower with EU (−3.62 ± 0.22) vs. HY (−2.93 ± 0.08; P = 0.044). Hypohydration did not significantly alter endothelium-independent CVC or LSR (both P > 0.05). In conclusion, hypohydration attenuated endothelium-dependent CVC but did not affect endothelium-independent CVC or LSR responses. These data suggest that reductions in skin blood flow accompanying hypohydration can be partially attributed to altered postsynaptic function.


2009 ◽  
Vol 107 (5) ◽  
pp. 1438-1444 ◽  
Author(s):  
Dean L. Kellogg ◽  
Joan L. Zhao ◽  
Yubo Wu

Nitric oxide (NO) participates in the cutaneous vasodilation caused by increased local skin temperature (Tloc) and whole body heat stress in humans. In forearm skin, endothelial NO synthase (eNOS) participates in vasodilation due to elevated Tloc and neuronal NO synthase (nNOS) participates in vasodilation due to heat stress. To explore the relative roles and interactions of these isoforms, we examined the effects of a relatively specific eNOS inhibitor, Nω-amino-l-arginine (LNAA), and a specific nNOS inhibitor, Nω-propyl-l-arginine (NPLA), both separately and in combination, on skin blood flow (SkBF) responses to increased Tloc and heat stress in two protocols. In each protocol, SkBF was monitored by laser-Doppler flowmetry (LDF) and mean arterial pressure (MAP) by Finapres. Cutaneous vascular conductance (CVC) was calculated (CVC = LDF/MAP). Intradermal microdialysis was used to treat one site with 5 mM LNAA, another with 5 mM NPLA, a third with combined 5 mM LNAA and 5 mM NPLA (Mix), and a fourth site with Ringer only. In protocol 1, Tloc was controlled with combined LDF/local heating units. Tloc was increased from 34°C to 41.5°C to cause local vasodilation. In protocol 2, after a period of normothermia, whole body heat stress was induced (water-perfused suits). At the end of each protocol, all sites were perfused with 58 mM nitroprusside to effect maximal vasodilation for data normalization. In protocol 1, at Tloc = 34°C, CVC did not differ between sites ( P > 0.05). LNAA and Mix attenuated CVC increases at Tloc = 41.5°C to similar extents ( P < 0.05, LNAA or Mix vs. untreated or NPLA). In protocol 2, in normothermia, CVC did not differ between sites ( P > 0.05). During heat stress, NPLA and Mix attenuated CVC increases to similar extents, but no significant attenuation occurred with LNAA ( P < 0.05, NPLA or Mix vs. untreated or LNAA). In forearm skin, eNOS mediates the vasodilator response to increased Tloc and nNOS mediates the vasodilator response to heat stress. The two isoforms do not appear to interact during either response.


2012 ◽  
Vol 112 (5) ◽  
pp. 791-797 ◽  
Author(s):  
Anna E. Stanhewicz ◽  
Rebecca S. Bruning ◽  
Caroline J. Smith ◽  
W. Larry Kenney ◽  
Lacy A. Holowatz

Functional constitutive nitric oxide synthase (NOS) is required for full expression of reflex cutaneous vasodilation that is attenuated in aged skin. Both the essential cofactor tetrahydrobiopterin (BH4) and adequate substrate concentrations are necessary for the functional synthesis of nitric oxide (NO) through NOS, both of which are reduced in aged vasculature through increased oxidant stress and upregulated arginase, respectively. We hypothesized that acute local BH4 administration or arginase inhibition would similarly augment reflex vasodilation in aged skin during passive whole body heat stress. Four intradermal microdialysis fibers were placed in the forearm skin of 11 young (22 ± 1 yr) and 11 older (73 ± 2 yr) men and women for local infusion of 1) lactated Ringer, 2) 10 mM BH4, 3) 5 mM ( S)-(2-boronoethyl)-l-cysteine + 5 mM Nω-hydroxy-nor-l-arginine to inhibit arginase, and 4) 20 mM NG-nitro-l-arginine methyl ester (l-NAME) to inhibit NOS. Red cell flux was measured at each site by laser-Doppler flowmetry (LDF) as reflex vasodilation was induced. After a 1.0°C rise in oral temperature (Tor), mean body temperature was clamped and 20 mM l-NAME was perfused at each site. Cutaneous vascular conductance was calculated (CVC = LDF/mean arterial pressure) and expressed as a percentage of maximum (%CVCmax; 28 mM sodium nitroprusside and local heat, 43°C). Vasodilation was attenuated at the control site of the older subjects compared with young beginning at a 0.3°C rise in Tor. BH4 and arginase inhibition both increased vasodilation in older (BH4: 55 ± 5%; arginase-inhibited: 47 ± 5% vs. control: 37 ± 3%, both P < 0.01) but not young subjects compared with control (BH4: 51 ± 4%CVCmax; arginase-inhibited: 55 ± 4%CVCmax vs. control: 56 ± 6%CVCmax, both P > 0.05) at a 1°C rise in Tor. With a 1°C rise in Tor, local BH4 increased NO-dependent vasodilation in the older (BH4: 31.8 ± 2.4%CVCmax vs. control: 11.7 ± 2.0%CVCmax, P < 0.001) but not the young (BH4: 23 ± 4%CVCmax vs. control: 21 ± 4%CVCmax, P = 0.718) subject group. Together these data suggest that reduced BH4 contributes to attenuated vasodilation in aged human skin and that BH4 NOS coupling mechanisms may be a potential therapeutic target for increasing skin blood flow during hyperthermia in older humans.


2013 ◽  
Vol 304 (8) ◽  
pp. R651-R656 ◽  
Author(s):  
Brett J. Wong

We tested the hypothesis that inhibition of cutaneous sensory nerves would attenuate reflex cutaneous vasodilation in response to an increase in core temperature. Nine subjects were equipped with four microdialysis fibers on the forearm. Two sites were treated with topical anesthetic EMLA cream for 120 min. Sensory nerve inhibition was verified by lack of sensation to a pinprick. Microdialysis fibers were randomly assigned as 1) lactated Ringer (control); 2) 10 mM nitro-l-arginine methyl ester (l-NAME) to inhibit nitric oxide synthase; 3) EMLA + lactated Ringer; and 4) EMLA + l-NAME. Laser-Doppler flowmetry was used as an index of skin blood flow, and blood pressure was measured via brachial auscultation. Subjects wore a water-perfused suit, and oral temperature was monitored as an index of core temperature. The suit was perfused with 50°C water to initiate whole body heat stress to raise oral temperature 0.8°C above baseline. Cutaneous vascular conductance (CVC) was calculated and normalized to maximal vasodilation (%CVCmax). There was no difference in CVC between control and EMLA sites (67 ± 5 vs. 69 ± 6% CVCmax), but the onset of vasodilation was delayed at EMLA compared with control sites. The l-NAME site was significantly attenuated compared with control and EMLA sites (45 ± 5% CVCmax; P < 0.01). Combined EMLA + l-NAME site (25 ± 6% CVCmax) was attenuated compared with control and EMLA ( P < 0.001) and l-NAME only ( P < 0.01). These data suggest cutaneous sensory nerves contribute to reflex cutaneous vasodilation during the early, but not latter, stages of heat stress, and full expression of reflex cutaneous vasodilation requires functional sensory nerves and NOS.


Author(s):  
Naoto Fujii ◽  
Glen P. Kenny ◽  
Gregory W. McGarr ◽  
Tatsuro Amano ◽  
Yasushi Honda ◽  
...  

Transient receptor potential vanilloid 4 (TRPV4) channels exist on vascular endothelial cells and eccrine sweat gland secretory cells in human skin. Here, we assessed if TRPV4 channels contribute to cutaneous vasodilation and sweating during whole-body passive heat stress (protocol 1) and to cutaneous vasodilation during post-occlusive reactive hyperemia and local thermal hyperemia (protocol 2). Intradermal microdialysis was employed to locally deliver pharmacological agents to forearm skin sites where cutaneous vascular conductance (CVC) and sweat rate were assessed. In protocol 1 (twelve young adults), CVC and sweat rate were increased by passive whole-body heating resulting in a body core temperature elevation of 1.2±0.1ºC. The elevated CVC and sweat rate assessed at sites treated with TRPV4 channel antagonist (either 200 µM HC-067047 or 125 µM GSK2193874) were not different from the vehicle control site (5 % dimethyl sulfoxide). After whole-body heating, a TRPV4 channel agonist (100 µM GSK1016790A) was administered to each skin site, eliciting elevations in CVC. Relative to control, this response was partly attenuated by both TRPV4 channel antagonists, confirming drug efficacy. In protocol 2 (ten young adults), CVC was increased following a 5-min arterial occlusion and during local heating from 33 to 42ºC. These responses did not differ between the control and the TRPV4 channel antagonist sites (200 µM HC-067047). We show that TRPV4 channels are not required for regulating cutaneous vasodilation or sweating during a whole-body passive heat stress. Further, they are not required for regulating cutaneous vasodilation during post-occlusive reactive hyperemia and local thermal hyperemia.


2019 ◽  
Vol 126 (4) ◽  
pp. 1129-1137 ◽  
Author(s):  
Robert D. Meade ◽  
Naoto Fujii ◽  
Gregory W. McGarr ◽  
Lacy M. Alexander ◽  
Pierre Boulay ◽  
...  

Age-related impairments in cutaneous vascular conductance (CVC) and sweat rate (SR) during exercise may result from increased arginase activity, which can attenuate endogenous nitric oxide (NO) production. We therefore evaluated whether arginase inhibition modulates these heat-loss responses in young ( n = 9, 23 ± 3 yr) and older ( n = 9, 66 ± 6 yr) men during two 30-min bouts of moderate-intensity cycling (Ex1 and Ex2) in the heat (35°C). CVC and SR were measured at forearm skin sites perfused with 1) lactated Ringer’s (control), 2) NG-nitro-L-arginine methyl ester (L-NAME; NO synthase-inhibited), or 3) Nω-hydroxy-nor-arginine and S-(2-boronoethyl)-l-cysteine (Nor-NOHA + BEC; arginase-inhibited). In both groups, CVC was reduced at L-NAME relative to control and Nor-NOHA + BEC (both P < 0.01). Likewise, SR was attenuated with L-NAME compared with control and Nor-NOHA + BEC during each exercise bout in the young men (all P ≤ 0.05); however, no influence of treatment on SR in the older men was observed ( P = 0.14). Based on these findings, we then evaluated responses in 7 older men (64 ± 7 yr) during passively induced elevations in esophageal temperature (∆Tes) equal to those in Ex1 (0.6°C) and Ex2 (0.8°C). L-NAME reduced CVC by 18 ± 20% CVCmax at a ∆Tes of 0.8°C ( P = 0.03) compared with control, whereas Nor-NOHA + BEC augmented CVC by 20 ± 18% CVCmax, on average, throughout heating (both P ≤ 0.03). SR was not influenced by either treatment ( P = 0.80) Thus, arginase inhibition does not modulate CVC or SR during exercise in the heat but, consistent with previous findings, does augment CVC in older men during passive heating. NEW & NOTEWORTHY In the current study, we demonstrate that local arginase inhibition does not influence forearm cutaneous vasodilatory and sweating responses in young or older men during exercise-heat stress. Consistent with previous findings, however, we observed augmented cutaneous blood flow with arginase inhibition during whole-body passive heat stress. Thus, arginase differentially affects cutaneous vasodilation depending on the mode of heat stress but does not influence sweating during exercise or passive heating.


2001 ◽  
Vol 281 (2) ◽  
pp. R591-R595 ◽  
Author(s):  
Ken Aoki ◽  
Dan P. Stephens ◽  
John M. Johnson

It is not clear whether the diurnal variation in the cutaneous circulatory response to heat stress is via the noradrenergic vasoconstrictor system or the nonadrenergic active vasodilator system. We conducted whole body heating experiments in eight male subjects at 0630 (AM) and 1630 (PM). Skin blood flow was monitored by laser-Doppler flowmetry at control sites and at sites pretreated with bretylium (BT) to block noradrenergic vasoconstriction. Noninvasive blood pressure was used to calculate cutaneous vascular conductance. The sublingual temperature (Tor) threshold for cutaneous vasodilation was significantly higher in PM at control and at BT-treated sites (both P < 0.01), suggesting the diurnal shift in threshold depends on the active vasodilator system. The slope of cutaneous vascular conductance as a percentage of its maximum with respect to Tor was significantly lower in AM at control sites only. Also, in the AM, the slope at control sites was significantly lower than that at BT-treated sites ( P < 0.05), suggesting that the diurnal change in the sensitivity of cutaneous vasodilation depends on vasoconstrictor system function. Overall, the diurnal variation in the reflex control of skin blood flow during heat stress involves both vasoconstrictor and active vasodilator systems.


1991 ◽  
Vol 71 (6) ◽  
pp. 2476-2482 ◽  
Author(s):  
D. L. Kellogg ◽  
J. M. Johnson ◽  
W. A. Kosiba

Exercise induces shifts in the internal temperature threshold at which cutaneous vasodilation begins. To find whether this shift is accomplished through the vasoconstrictor system or the cutaneous active vasodilator system, two forearm sites (0.64 cm2) in each of 11 subjects were iontophoretically treated with bretylium tosylate to locally block adrenergic vasoconstrictor control. Skin blood flow was monitored by laser-Doppler flowmetry (LDF) at those sites and at two adjacent untreated sites. Mean arterial pressure (MAP) was measured noninvasively. Cutaneous vascular conductance was calculated as LDF/MAP. Forearm sweat rate was also measured in seven of the subjects by dew point hygrometry. Whole body skin temperature was raised to 38 degrees C, and supine bicycle ergometer exercise was then performed for 7–10 min. The internal temperature at which cutaneous vasodilation began was recorded for all sites, as was the temperature at which sweating began. The same subjects also participated in studies of heat stress without exercise to obtain vasodilator and sudomotor thresholds from rest. The internal temperature thresholds for cutaneous vasodilation were higher during exercise at both bretylium-treated (36.95 +/- 0.07 degrees C rest, 37.20 +/- 0.04 degrees C exercise, P less than 0.05) and untreated sites (36.95 +/- 0.06 degrees C rest, 37.23 +/- 0.05 degrees C exercise, P less than 0.05). The thresholds for cutaneous vasodilation during rest or during exercise were not statistically different between untreated and bretylium-treated sites (P greater than 0.05). The threshold for the onset of sweating was not affected by exercise (P greater than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


2017 ◽  
Vol 118 (1) ◽  
pp. 7-14 ◽  
Author(s):  
Dustin R. Allen ◽  
Mu Huang ◽  
Iqra M. Parupia ◽  
Ariana R. Dubelko ◽  
Elliot M. Frohman ◽  
...  

Multiple sclerosis (MS) is an autoimmune disease that affects the central nervous system (CNS), disrupting autonomic function. The aim of this study was to test the hypothesis that individuals with MS have blunted control of thermoregulatory reflex increases in sweat rate (SR) and cutaneous vasodilation compared with controls during a passive whole body heat stress (WBH). Eighteen individuals with relapsing-remitting MS and 18 healthy controls (Con) participated in the study. Core temperature (Tcore), skin temperature, heart rate, arterial blood pressure (10-min intervals), skin blood flow (laser-Doppler flux, LDF), and SR were continuously measured during normothermic baseline (34°C water perfusing a tube-lined suit) and WBH (increased Tcore 0.8°C via 48°C water perfusing the suit). Following WBH, local heaters were warmed to 42°C, inducing peak cutaneous vasodilation at the site of LDF collection. Cutaneous vascular conductance (CVC) was calculated as the ratio of LDF to mean arterial pressure and expressed as a percentage of peak achieved during local heating. Individuals with MS had attenuated SR responses to WBH (ΔSR from baseline: Con, 0.65 ± 0.27; MS, 0.42 ± 0.17 mg·cm−2·min−1, P = 0.003), whereas Δ%CVC42C from baseline was similar between groups (Con, 42 ± 16%; MS, 38 ± 12%, P = 0.39). SR responses were blunted as a function of Tcore in MS (interaction: group × Tcore, P = 0.03), of which differences were evident at ΔTcore 0.7°C and 0.8°C ( P < 0.05). No interaction was observed in Δ%CVC42C. Taken together, the findings show MS blunts sweating responses, whereas control of the cutaneous vasculature is preserved, in response to WBH. NEW & NOTEWORTHY This study is the first to assess the reflex control of the thermoregulatory system in individuals living with multiple sclerosis (MS). The novel findings are twofold. First, attenuated increases in sweat rate in subjects with MS compared with healthy controls were observed in response to a moderate increase (0.8°C) in core temperature via passive whole body heat stress. Second, it appears the reflex control of the cutaneous vasculature is preserved in MS.


Sign in / Sign up

Export Citation Format

Share Document