Thoracoabdominal blood volume change and its effect on lung and chest wall volumes

1986 ◽  
Vol 61 (3) ◽  
pp. 953-959 ◽  
Author(s):  
W. R. Kimball ◽  
K. B. Kelly ◽  
J. Mead

The effects of changing blood volume within the thoracoabdominal cavity (Vtab) have been studied in four male subjects trained in respiratory maneuvers. Subjects were studied lying supine in a pressure plethysmograph with inflatable fracture splints placed around both arms and legs. Changes in Vtab were produced by inflating the splints to 30 cmH2O. Thoracic gas volume (Vtg) measured by Boyle's law, and the change in chest wall volume (delta Vw), measured by anteroposterior magnetometers on rib cage and abdomen, were measured almost simultaneously and at two respiratory system volumes. The quantity of blood moved by splint inflation was estimated for each subject at both respiratory system volumes and varied between 215 and 752 ml. The chest wall increased 64 +/- 11.8% (mean +/- SD) of the increase in Vtab. Thus increases in thoracoabdominal blood volume increase Vw about twice the decrease in Vtg.

1985 ◽  
Vol 58 (6) ◽  
pp. 1783-1787 ◽  
Author(s):  
L. J. Folinsbee ◽  
J. F. Bedi ◽  
S. M. Horvath

We exposed 22 healthy adult nonsmoking male subjects for 2 h to filtered air, 1.0 ppm sulfur dioxide (SO2), 0.3 ppm ozone (O3), or the combination of 1.0 ppm SO2 + 0.3 ppm O3. We hypothesized that exposure to near-threshold concentrations of these pollutants would allow us to observe any interaction between the two pollutants that might have been masked by the more obvious response to the higher concentrations of O3 used in previous studies. Each subject alternated 30-min treadmill exercise with 10-min rest periods for the 2 h. The average exercise ventilation measured during the last 5 min of exercise was 38 1/min (BTPS). Forced expiratory maneuvers were performed before exposure and 5 min after each of the three exercise periods. Maximum voluntary ventilation, He dilution functional residual capacity, thoracic gas volume, and airway resistance were measured before and after the exposure. After O3 exposure alone, forced expiratory measurements (FVC, FEV1.0, and FEF25–75%) were significantly decreased. The combined exposure to SO2 + O3 produced similar but smaller decreases in these measures. There were small but significant differences between the O3 and the O3 + SO2 exposure for FVC, FEV1.0, FEV2.0, FEV3.0, and FEF25–75% at the end of the 2-h exposure. We conclude that, with these pollutant concentrations, there is no additive or synergistic effect of the two pollutants on pulmonary function.


1987 ◽  
Vol 63 (3) ◽  
pp. 951-961 ◽  
Author(s):  
D. R. Hillman ◽  
K. E. Finucane

The interaction of forces that produce chest wall motion and lung volume change is complex and incompletely understood. To aid understanding we have developed a simple model that allows prediction of the effect on chest wall motion of changes in applied forces. The model is a lever system on which the forces generated actively by the respiratory muscles and passively by impedances of rib cage, lungs, abdomen, and diaphragm act at fixed sites. A change in forces results in translational and/or rotational motion of the lever; motion represents volume change. The distribution and magnitude of passive relative to active forces determine the locus and degree of rotation and therefore the effect of an applied force on motion of the chest wall, allowing the interaction of diaphragm, rib cage, and abdomen to be modeled. Analysis of moments allow equations to be derived that express the effect on chest wall motion of the active component in terms of the passive components. These equations may be used to test the model by comparing predicted with empirical behavior. The model is simple, appears valid for a variety of respiratory maneuvers, is useful in interpreting relative motion of rib cage and abdomen and may be useful in quantifying the effective forces acting on the rib cage.


1995 ◽  
Vol 78 (3) ◽  
pp. 938-947 ◽  
Author(s):  
M. Rotger ◽  
R. Farre ◽  
R. Peslin ◽  
D. Navajas

The aim of this work was to demonstrate that the three compartments of the lung T network and the chest wall impedance (Zcw) can be identified from input and transfer impedances of the respiratory system if the pleural pressure is recorded during the measurements. The method was tested in six healthy volunteers in the range of 8–32 Hz. The impedances resulting from the decomposition confirm the adequacy of the monoalveolar structure commonly used in healthy subjects. Indeed, the T shunt impedance is well modeled by a purely compliant element, the mean compliance [0.038 +/- 0.081 (SD) l/kPa], which coincides within 9.5 +/- 6.3% of the alveolar gas compressibility derived from thoracic gas volume (0.036 +/- 0.011 l/kPa). The results obtained provide experimental evidence that the alveolar gas compression is predominantly isothermal and that lung tissue impedance is negligible throughout the whole frequency range. The shape of Zcw is consistent with a low compliance-low inertance pathway in parallel with a high compliance-high inertance pathway. We conclude that the proposed method is able to reliably identify the T network featuring the lung and Zcw.


1998 ◽  
Vol 84 (4) ◽  
pp. 1475-1479 ◽  
Author(s):  
Megan A. McCrory ◽  
Paul A. Molé ◽  
Terri D. Gomez ◽  
Kathryn G. Dewey ◽  
Edmund M. Bernauer

The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle’s law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtgpred). The validity of using Vtgpred in place of measured Vtg (Vtgmeas) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18–56 yr). There was no significant difference between Vtgmeas and Vtgpred (mean difference ± SE, 53.5 ± 63.3 ml) nor in %BF by using Vtgmeas vs. Vtgpred (0.2 ± 0.2 %BF). On an individual basis, %BF measured by using Vtgmeas vs. Vtgpred differed within ±2.0% BF for 82% of the subjects; maximum differences were −2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (Vr pred vs. Vr meas, respectively). Differences between Vr meas and Vr pred and in %BF calculated by using Vr meas vs. Vr pred were significant (187 ± 46 ml and 1.4 ± 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using Vr meas vs. Vr preddiffered within ±2.0% BF for 46% of the subjects; maximum differences were −2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtgpred for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of Vr pred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtgpred has some application, determining Vtgmeas is relatively simple in most cases. Therefore, we recommend that the use of Vtgmeas remain as standard experimental and clinical practice.


1992 ◽  
Vol 72 (1) ◽  
pp. 186-193 ◽  
Author(s):  
H. J. Colebatch ◽  
C. K. Ng ◽  
N. Berend ◽  
F. J. Maccioni

To determine the reason for increased pulmonary distensibility in excised lungs, we performed deflation pressure-volume (PV) studies in 24 dogs. Exponential analysis of PV data gave K, an index of distensibility. Lung volume was measured by dilution of neon. Compared with measurements obtained in the supine position, with the chest closed, and with esophageal pressure (Pes) to obtain transpulmonary pressure, K was not changed significantly with the chest strapped, with pleural pressure to obtain transpulmonary pressure, or with the chest open. From displacement of PV curves obtained in the supine position and with the chest closed or open, we estimated that Pes was 0.18 kPa greater than average lung surface pressure. An increase in K in the prone and head-up positions was attributed to a traction artifact decreasing Pes. Exsanguination increased K and produced a relative increase in gas volume. These results show that overall pulmonary distensibility is unaffected by an intact chest wall. An increase in K and gas volume after exsanguination probably reflects a decreased pulmonary blood volume, with collapse of capillaries increasing the alveolar volume-to-surface ratio.


1982 ◽  
Vol 52 (3) ◽  
pp. 798-801 ◽  
Author(s):  
A. Harf ◽  
H. Lorino ◽  
G. Atlan ◽  
A. M. Lorino ◽  
D. Laurent

To improve the computer determination of thoracic gas volume (TGV), two new approaches were worked out. 1) A new program was designed, which overcomes the difficulties encountered in the time recognition of the panting maneuver and rules out the artifacts. Such a procedure is based on the data analysis in the pressure-volume time derivatives plane. 2) A hyperbolic fitting of the signals recorded during the panting maneuver was introduced. This last procedure, lying on Boyle's law, has proved to be useful in case of large mouth pressure changes. In fact the error induced by the conventional linear fitting may reach 500 ml (9% of the TGV value).


2019 ◽  
Vol 127 (6) ◽  
pp. 1640-1650 ◽  
Author(s):  
Antonella LoMauro ◽  
Andrea Aliverti ◽  
Peter Frykholm ◽  
Daniela Alberico ◽  
Nicola Persico ◽  
...  

A plethora of physiological and biochemical changes occur during normal pregnancy. The changes in the respiratory system have not been as well elucidated, in part because radioimaging is usually avoided during pregnancy. We aimed to use several noninvasive methods to characterize the adaptation of the respiratory system during the full course of pregnancy in preparation for childbirth. Eighteen otherwise healthy women (32.3 ± 2.8 yr) were recruited during early pregnancy. Spirometry, optoelectronic plethysmography, and ultrasonography were used to study changes in chest wall geometry, breathing pattern, lung and thoraco-abdominal volume variations, and diaphragmatic thickness in the first, second, and third trimesters. A group of nonpregnant women were used as control subjects. During the course of pregnancy, we observed a reorganization of rib cage geometry, in shape but not in volume. Despite the growing uterus, there was no lung restriction (forced vital capacity: 101 ± 15% predicted), but we did observe reduced rib cage expansion. Breathing frequency and diaphragmatic contribution to tidal volume and inspiratory capacity increased. Diaphragm thickness was maintained (1st trimester: 2.7 ± 0.8 mm, 3rd trimester: 2.5 ± 0.9 mm; P = 0.187), possibly indicating a conditioning effect to compensate for the effects of the growing uterus. We conclude that pregnancy preserved lung volumes, abdominal muscles, and the diaphragm at the expense of rib cage muscles. NEW & NOTEWORTHY Noninvasive analysis of the kinematics of the chest wall and the diaphragm during resting conditions in pregnant women revealed significant changes in the pattern of thoracoabdominal breathing across the trimesters. That is, concomitant with the progressive changes of chest wall shape, the diaphragm increased its contribution to both spontaneous and maximal breathing, maintaining its thickness despite its lengthening due to the growing uterus. These results suggest that during pregnancy the diaphragm is conditioned to optimize its active role provided during parturition.


1978 ◽  
Vol 44 (3) ◽  
pp. 469-473 ◽  
Author(s):  
R. Brown ◽  
F. G. Hoppin ◽  
R. H. Ingram ◽  
N. A. Saunders ◽  
E. R. McFadden

In a body plethysmograph we have demonstrated differences in total lung capacity (TLC) derived from panting maneuvers performed at different levels in the vital capacity. In almost all cases, the discrepancies were due to the magnitude of the abdominal gas volume (AGV) and the relative magnitude of abdominal and thoracic pressure swings during the panting mandeuver. When panting was performed at functional residual capacity (FRC), the effect of AGV compression on the determination of thoracid gas volume (TGV) was small. Of 11 individuals studied 2 were known to have mild asthma. Compression and decompression of AGV appeared to be an insufficient explanation for discrepancies in derived TLC's in these two, suggesting that other as yet unidentified factors may influence the plethysmographic determination of TGV.


1989 ◽  
Vol 67 (4) ◽  
pp. 1472-1478 ◽  
Author(s):  
B. R. Boynton ◽  
G. Glass ◽  
I. D. Frantz ◽  
J. J. Fredberg

Allen et al. (J. Clin. Invest. 76: 620–629, 1985) reported that during oscillatory forcing the base of isolated canine lungs distends preferentially relative to the apex as frequency and tidal volume increase. The tendency toward such nonuniform phasic lung distension might influence phasic displacement of the rib cage (RC) relative to the abdomen (ABD). To test this hypothesis we measured RC and ABD displacement in four anesthetized dogs during forced oscillation. Sinusoidal volume changes were delivered through a tracheostomy at 1–32 Hz and measured by body plethysmography. RC and ABD displacements were measured by inductive plethysmography. During oscillation with air at fixed tidal volumes (10–80 ml) RC, normalized to unity at 1 Hz, increased to 2.06–2.22 at 8 Hz (P less than 0.001) and then decreased to 1.06–1.35 (P less than 0.0025) at 32 Hz. ABD, normalized to unity at 1 Hz, was 1.12–1.16 at 4 Hz (P less than 0.001) and decreased to 0.12–0.14 at 32 Hz (P less than 0.001). Displacement of ABD relative to RC did not increase systematically with increasing tidal volume during sinusoidal forcing at any frequency. Thus we found no discernible influence of nonuniform phasic lung distension on chest wall behavior. We infer that in the dog the nonuniform mechanical behavior of the chest wall dominates the nonuniform (but opposing) mechanical tendency of the lung.


Sign in / Sign up

Export Citation Format

Share Document