scholarly journals Validation and Application of a New Reversed Phase HPLC Method forIn VitroDissolution Studies of Rabeprazole Sodium in Delayed-Release Tablets

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Md. Saddam Nawaz

The purpose of this study was to develop and validate a new reversed phase high performance liquid chromatographic (RP-HPLC) method to quantifyin vitrodissolution assay of rabeprazole sodium in pharmaceutical tablet dosage form. Method development was performed on C 18,100×4.6 mm ID, and 10 μm particle size column, and injection volume was 20 μL using a diode array detector (DAD) to monitor the detection at 280 nm. The mobile phase consisted of buffer: acetonitrile at a ratio of 60 : 40 (v/v), and the flow rate was maintained at 1.0 mL/min. The method was validated in terms of suitability, linearity, specificity, accuracy, precision, stability, and sensitivity. Linearity was observed over the range of concentration 0.05–12.0 μg/mL, and the correlation coefficient was found excellent >0.999. The method was specific with respect to rabeprazole sodium, and the peak purity was found 99.99%. The method was precise and had relative standard deviations (RSD) less than 2%. Accuracy was found in the range of 99.9 to 101.9%. The method was robust in different variable conditions and reproducible. This proposed fast, reliable, cost-effective method can be used as quality control tool for the estimation of rabeprazole sodium in routine dissolution test analysis.

Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


2008 ◽  
Vol 91 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanolwater (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 g/mL. The values for interday and intraday precision (relative standard deviation) were &lt;1. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.


1970 ◽  
Vol 3 (1) ◽  
pp. 49-53 ◽  
Author(s):  
Gaurav Patel ◽  
Sanjay Patel ◽  
Dhamesh Prajapiti ◽  
Rajendra Mehta

A reverse phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in combine dosage form. Amlodipine Besylate (AML) is a long acting calcium channel blocker and in the treatment of CVS disorder. Hydrochlorothiazide (HCT) is a diuretic and antihypertensive. The mobile phase used was a combination of Water: Methanol (70:30). The detection of the combined dosage form was carried out at 245nm and a flow rate employd was 0.5ml/min. The retention time for Amlodipine Besylate and Hydrochlorothiazide was found to be 6.95 and 2.65 min respectively. Linearity was obtained in the concentration range of 6 to 18μg/ml of Amlodipine Besylate and 6 to 18μg/ml of Hydrochlorothiazide with a correlation coefficient of 0.997 and 0.9974. Detector consists of photodiode array detector; the reversed phase column used was RP-C18 (5 μm size, 250mm, 4.6mm i.d.) at ambient temperature. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method is precise, selective and rapid for simultaneous estimation of Amlodipine Besylate and Hydrochlorothiazide in routine analysis. Key Words: Simultaneous Estimation; Amlodipine Besylate; Hydrochlorothiazide; HPLC. DOI: 10.3329/sjps.v3i1.6798S. J. Pharm. Sci. 3(1): 49-53


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


Author(s):  
Grishma H Patel ◽  
Shreya D Adeshra ◽  
Dhananjay B Meshram

A Novel, selective, accurate and rapid Reversed Phase High Performance Liquid Chromatographic (RPHPLC) method for the analysis of Efonidipine Hydrochloride Ethanolate and Telmisartan in binary mixture has been developed and validated. The chromatographic system consisted of a Phenomenex Kinetex ® 5µ C18 Size: 150 * 4.6mm column and the separation was achieved by using ambient temperature with a mobile phase containing mobile Phase Acetonitrile:25mM Phosphate Buffer pH 4.9 (45:55). The samples were monitored at 253 nm for detection at a flow rate of 1.0 mL/min and the retention time was about 7.77 and 4.10 mins for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The calibration curve was linear over the concentration range 5-30 and 10-60 ?g/mL for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The proposed method is accurate in the range of 99.75% - 100.10% recovery and precise (%RSD of intraday variation and % RSD of inter day variation were found to be within the acceptance criteria). Therefore, this method can be used as a more convenient and efficient option for the analysis of Efonidipine Hydrochloride Ehanolate and Telmisartan in Quality control laboratory.


2020 ◽  
Vol 2020 ◽  
pp. 1-9 ◽  
Author(s):  
Mohyeddin Assali ◽  
Murad Abualhasan ◽  
Nihal Zohud ◽  
Noura Ghazal

Background. Indomethacin is considered a potent nonsteroidal anti-inflammatory drug that could be combined with Paracetamol to have superior and synergist activity to manage pain and inflammation. To reduce the gastric side effect, they could be combined with Famotidine. Methodology. A codrug of Indomethacin and Paracetamol was synthesized and combined in solution with Famotidine. The quantification of the pharmaceutically active ingredients is pivotal in the development of pharmaceutical formulations. Therefore, a novel reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated according to the International Council for Harmonization (ICH) Q2R1 guidelines. A reverse phase C18 column with a mobile phase acetonitrile: sodium acetate buffer 60 : 40 at a flow rate of 1.4 mL/min and pH 5 was utilized. Results. The developed method showed good separation of the four tested drugs with a linear range of 0.01–0.1 mg/mL (R2 > 0.99). The LODs for FAM, PAR, IND, and codrug were 3.076 × 10−9, 3.868 × 10−10, 1.066 × 10−9, and 4.402 × 10−9 mg/mL respectively. While the LOQs were 9.322 × 10−9, 1.172 × 10−10, 3.232 × 10−9, and 1.334 × 10−8 mg/mL, respectively. Furthermore, the method was precise, accurate, selective, and robust with values of relative standard deviation (RSD) less than 2%. Moreover, the developed method was applied to study the in vitro hydrolysis and conversion of codrug into Indomethacin and Paracetamol. Conclusion. The codrug of Indomethacin and Paracetamol was successfully synthesized for the first time. Moreover, the developed analytical method, to our knowledge, is the first of its kind to simultaneously quantify four solutions containing the following active ingredients of codrug, Indomethacin, Paracetamol, and Famotidine mixture with added pharmaceutical inactive ingredients in one HPLC run.


2008 ◽  
Vol 91 (2) ◽  
pp. 332-338 ◽  
Author(s):  
Branislava Mielji ◽  
Gordana Popovi ◽  
Danica Agbaba ◽  
Slavko Markovi ◽  
Breda Simonovska ◽  
...  

Abstract A gradient reversed-phase column high-performance liquid chromatographic method was developed for the detection and quantification of norfloxacin and its major impurities in norfloxacin-containing pharmaceuticals. Chromatographic separations were performed under the following experimental conditions: column, Zorbax SB RP-18 (5 m, 250 4.6 mm); injection volume, 20 L; mobile phase, 0.05 M NaH2PO4 (pH 2.5)acetonitrile (87 + 13) for 16 min and (58 + 42) for 9 min (stepwise gradient); and flow rate, 1.3 mL/min. All analyses were performed at 25C, and the eluate was monitored at 275 nm using a diode array detector. Linearity (correlation coefficient = 0.999), recovery (99.3101.8), relative standard deviation (0.20.7), and quantitation limit (0.120.47 g/mL) were evaluated and found to be satisfactory. The method is simple, rapid, and convenient for purity control of norfloxacin in both raw materials and dosage forms.


2010 ◽  
Vol 2010 ◽  
pp. 1-5 ◽  
Author(s):  
Ayman Khdair ◽  
Mohammad K. Mohammad ◽  
Khaled Tawaha ◽  
Eman Al-Hamarsheh ◽  
Hatim S. AlKhatib ◽  
...  

A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup. Separation of hederacoside C was achieved using a Phenomenex-Gemini C18 column isothermally at C. A mobile phase system constituted of solvent A (water: acetonitrile: orthophosphoric acid (85%), 860 : 140 : 2 v/v) and solvent B (acetonitrile: orthophosphoric acid (85%), 998 : 2 v/v) was used, at gradient conditions, at a flow rate of 1.5 mL/min. Analysis was performed using UV-detection (205 nm). The method was linear over the range (0.03–0.15) mg/mL of hederacoside C (). Repeatability and intermediate precision were acceptable (RSD %). Limits of detection (LOD) and quantitation (LOQ) were 0.011 and 0.032 mg/mL, respectively. Percentage recovery was found to lie between 99.69% and 100.90% (RSD %). The method was also proved to be specific (peak-purity ).


2013 ◽  
Vol 5 (2) ◽  
pp. 335-342 ◽  
Author(s):  
R. Kayesh ◽  
M. Z. Sultan ◽  
A. Rahman ◽  
M. G. Uddin ◽  
F. Aktar ◽  
...  

A rapid and highly sensitive reversed phase high performance liquid chromatographic method has been developed for quantitative estimation of omeprazole in pharmaceutical preparations. The method has been validated according to FDA and USP guidelines with respect to accuracy, precision, specificity and linearity. The method was developed by using a gradient condition of mobile phase comprising 90% aqueous acetonitrile to 100% acetonitrile for 10 minutes at a flow rate of 0.7 mL/min over C-18 (ODS, 250 x 4.6 mm) column at ambient temperature. More than 97% recovery demonstrated the accuracy of the protocol. Intra-day and inter-day precision studies of the new method were less than the maximum allowable limit (RSD% £ 2.0 according to FDA). The method showed linear response with correlation coefficient (r2) value of 0.998.  Therefore, it was found to be accurate, reproducible, sensitive and less time consuming and can be successfully applied for the assay of omeprazole formulations.Keywords: HPLC; Method development; Gradient condition; Validation; Omeprazole.© 2013 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.doi: http://dx.doi.org/10.3329/jsr.v5i2.12779        J. Sci. Res. 5 (2), 335-342  (2013)