scholarly journals Study on the Depth, Rate, Shape, and Strength of Pulse with Cardiovascular Simulator

2017 ◽  
Vol 2017 ◽  
pp. 1-11 ◽  
Author(s):  
Ju-Yeon Lee ◽  
Min Jang ◽  
Sang-Hoon Shin

Pulse diagnosis is important in oriental medicine. The purpose of this study is explaining the mechanisms of pulse with a cardiovascular simulator. The simulator is comprised of the pulse generating part, the vessel part, and the measurement part. The pulse generating part was composed of motor, slider-crank mechanism, and piston pump. The vessel part, which was composed with the aorta and a radial artery, was fabricated with silicon to implement pulse wave propagation. The pulse parameters, such as the depth, rate, shape, and strength, were simulated. With changing the mean pressure, the floating pulse and the sunken pulse were generated. The change of heart rate generated the slow pulse and the rapid pulse. The control of the superposition time of the reflected wave generated the string-like pulse and the slippery pulse. With changing the pulse pressure, the vacuous pulse and the replete pulse were generated. The generated pulses showed good agreements with the typical pulses.

2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Min Jang ◽  
Min-Woo Lee ◽  
Jaeuk U. Kim ◽  
See-Yoon Seo ◽  
Sang-Hoon Shin

This research was undertaken to develop a cardiovascular simulator for use in the study of pulse diagnosis. The physical (i.e., pulse wave transmission and reflection) and physiological (i.e., systolic and diastolic pressure, pulse pressure, and mean pressure) characteristics of the radial pulse wave were reproduced by our simulator. The simulator consisted of an arterial component and a pulse-generating component. Computer simulation was used to simplify the arterial component while maintaining the elastic modulus and artery size. To improve the reflected wave characteristics, a palmar arch was incorporated within the simulator. The simulated radial pulse showed good agreement with clinical data.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Piayda ◽  
A Wimmer ◽  
H Sievert ◽  
K Hellhammer ◽  
S Afzal ◽  
...  

Abstract Background In the era of transcatheter aortic valve replacement (TAVR), there is renewed interest in percutaneous balloon aortic valvuloplasty (BAV), which may qualify as the primary treatment option of choice in special clinical situations. Success of BAV is commonly defined as a significant mean pressure gradient reduction after the procedure. Purpose To evaluate the correlation of the mean pressure gradient reduction and increase in the aortic valve area (AVA) in different flow and gradient patterns of severe aortic stenosis (AS). Methods Consecutive patients from 01/2010 to 03/2018 undergoing BAV were divided into normal-flow high-gradient (NFHG), low-flow low-gradient (LFLG) and paradoxical low-flow low-gradient (pLFLG) AS. Baseline characteristics, hemodynamic and clinical information were collected and compared. Additionally, the clinical pathway of patients (BAV as a stand-alone procedure or BAV as a bridge to aortic valve replacement) was followed-up. Results One-hundred-fifty-six patients were grouped into NFHG (n=68, 43.5%), LFLG (n=68, 43.5%) and pLFLG (n=20, 12.8%) AS. Underlying reasons for BAV and not TAVR/SAVR as the primary treatment option are displayed in Figure 1. Spearman correlation revealed that the mean pressure gradient reduction had a moderate correlation with the increase in the AVA in patients with NFHG AS (r: 0.529, p<0.001) but showed no association in patients with LFLG (r: 0.145, p=0.239) and pLFLG (r: 0.030, p=0.889) AS. Underlying reasons for patients to undergo BAV and not TAVR/SAVR varied between groups, however cardiogenic shock or refractory heart failure (overall 46.8%) were the most common ones. After the procedure, independent of the hemodynamic AS entity, patients showed a functional improvement, represented by substantially lower NYHA class levels (p<0.001), lower NT-pro BNP levels (p=0.003) and a numerical but non-significant improvement in other echocardiographic parameters like the left ventricular ejection fraction (p=0.163) and tricuspid annular plane systolic excursion (TAPSE, p=0.066). An unplanned cardiac re-admission due to heart failure was necessary in 23.7% patients. Less than half of the patients (44.2%) received BAV as a bridge to TAVR/SAVR (median time to bridge 64 days). Survival was significantly increased in patients having BAV as a staged procedure (log-rank p<0.001). Conclusion In daily clinical practice, the mean pressure gradient reduction might be an adequate surrogate of BAV success in patients with NFHG AS but is not suitable for patients with other hemodynamic entities of AS. In those patients, TTE should be directly performed in the catheter laboratory to correctly assess the increase of the AVA. BAV as a staged procedure in selected clinical scenarios increases survival and is a considerable option in all flow states of severe AS. (NCT04053192) Figure 1 Funding Acknowledgement Type of funding source: None


1993 ◽  
Vol 75 (1) ◽  
pp. 148-154 ◽  
Author(s):  
S. Isono ◽  
D. L. Morrison ◽  
S. H. Launois ◽  
T. R. Feroah ◽  
W. A. Whitelaw ◽  
...  

The static mechanics of the hypotonic pharynx were endoscopically evaluated in nine sleeping patients with obstructive sleep apnea, having a primary narrowing only at the velopharynx. The velopharynx closed completely at a mean pressure of 0.18 +/- 1.21 cmH2O, and the mean half-dilation pressure was 1.93 cmH2O above closing pressure. The dependence of area on pressure was distinctly curvilinear, being steep near closing pressure and asymptotically approaching maximum area (mean = 1.32 cm2). The data for each patient were satisfactorily fitted by an exponential function (mean R2 = 0.98), and a single exponential relationship usefully represented the dependence of relative area on pressure above closing pressure for the population (R2 = 0.85). During the test inspiration, flow limitation was consistently observed when mask pressure exceeded closing pressure by 0.5–3.0 cmH2O. In summary, the static mechanics of the hypotonic velopharynx of patients with obstructive sleep apnea can be described by an exponential pressure-area relationship, with a closing pressure near atmospheric pressure and a high compliance in the range of airway pressure 0–3 cmH2O above closing pressure.


1977 ◽  
Vol 99 (3) ◽  
pp. 503-509 ◽  
Author(s):  
B. E. Lee ◽  
B. F. Soliman

A study has been made of the influence of grouping parameters on the mean pressure distributions experienced by three dimensional bluff bodies immersed in a turbulent boundary layer. The range of variable parameters has included group density, group pattern and incident flow type and direction for a simple cuboid element form. The three flow regimes associated with increasing group density are reflected in both the mean drag forces acting on the body and their associated pressure distributions. A comparison of both pressure distributions and velocity profile parameters with established work on two dimensional bodies shows close agreement in identifying these flow regime changes. It is considered that the application of these results may enhance our understanding of some common flow phenomena, including turbulent flow over rough surfaces, building ventilation studies and environmental wind around buildings.


Sign in / Sign up

Export Citation Format

Share Document