scholarly journals Corneal Endothelial Cell Density and Morphology in Healthy Egyptian Eyes

2019 ◽  
Vol 2019 ◽  
pp. 1-8 ◽  
Author(s):  
Marwa Mahmoud Abdellah ◽  
Hatem Gamal Ammar ◽  
Mohamed Anbar ◽  
Engy Mohammed Mostafa ◽  
Mahmoud Mohamed Farouk ◽  
...  

Purpose. To evaluate the corneal endothelial cell density and morphology in normal Egyptian eyes. Methods. In total, 568 healthy eyes of 568 Egyptian volunteers aged 20 to 85 years were examined using noncontact specular microscopy for the central corneal thickness (CCT), mean endothelial cell density (MCD), coefficient of variation (CV) in cell area, mean cell area (MCA), and hexagonal cell (Hex) percentage. Variables were compared between sexes and between different age groups. Results. The mean CCT, MCD, and MCA were 514.45 ± 43.04 μm, 2647.50 ± 382.62 cells/mm2, and 390.59 ± 149.94 μm2, respectively. MCD and MCA showed no significant differences between men and women (P=0.171 and 0.099, respectively), whereas CV (%) and Hex (%) showed significant differences (P=0.024 and 0.015, respectively). CCT (P=0.007, r = −0.113) and MCD (P<0.001, r = −0.357) exhibited a significant negative correlation with age, whereas CV (%) (P<0.001, r = 0.341) and MCA (P=0.008, r = 0.111) exhibited a significant positive correlation. The mean rate of endothelial cell loss from 20 to 85 years of age was 0.3% per year. Conclusions. Our results provide normative data for the corneal endothelium in healthy Egyptian eyes, thus increasing the knowledge base for corneal endothelial cell parameters in healthy Egyptian eyes. Furthermore, our findings can be used as baseline values for comparisons between Egyptian and other populations and for studies of the endothelial cell reserve and capacity for intraocular surgery and corneal transplantation.

2017 ◽  
Vol 47 (12) ◽  
Author(s):  
Gustavo Brambatti ◽  
Luciane de Albuquerque ◽  
Eduarda Valim Borges de Vargas ◽  
Carolina Fonseca Neumann ◽  
João Antonio Tadeu Pigatto

ABSTRACT: The goal of this study was to describe the normal values of corneal endothelial cell density and hexagonality in healthy rabbits’ eyes using contact specular microscopy. Both eyes of 18 rabbits, males and females, of different ages were evaluated. The eyes were divided into three groups of 12 each according to the age range of the animals: G1 (6 months old), G2 (12 months old), and G3 (48 months old). Parameters studied included mean endothelial cell density and hexagonality. For Group I, the mean cell density was 2307 cells per mm2. For GII, the mean cell density was 1895 cells per mm2. For G III, the mean cell density was 1818 cells per mm2. Cell density decreased significantly with aging (P<0.001) among the three groups. Pleomorphism in the rabbits of GI was 74.33±10.08. In the rabbits of GII it was 71.83±11.38. In the rabbits of GIII it was 64.02±28.80. Significant differences (P<0.001) were evident between GI and GIII and GII and GIII but not between Groups I and II. The results showed a decrease in number of cells and hexagonality with aging. Corneal endothelium of rabbits suffers changes due to advancing age both in terms of cell density and morphology.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Tatsuya Jujo ◽  
Jiro Kogo ◽  
Hiroki Sasaki ◽  
Reio Sekine ◽  
Keiji Sato ◽  
...  

Abstract Backgrounds However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. Methods Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o’clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. Results The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was − 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


Cornea ◽  
2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Kanae Kayukawa ◽  
Koji Kitazawa ◽  
Koichi Wakimasu ◽  
Sanjay V. Patel ◽  
John Bush ◽  
...  

2018 ◽  
Vol 5 (3) ◽  
pp. 694 ◽  
Author(s):  
Nagaraj G. ◽  
Anasuya Sangaraj Desai ◽  
Nagesh Jayaram

Background: Diabetes mellitus is associated with structural changes in corneal endothelial cells and their thickness. The present study was done to compare the endothelial cell density (ECD), central corneal thickness (CCT) and morphology in diabetic and non-diabetic patients.Methods: A cross-sectional study was conducted at Minto Ophthalmic hospital, BMC and RI Bangalore for a period of 20 months (October 2013 - May 2015). A total of 200 study subjects, 100 diabetics and 100 non-diabetic age matched controls were selected, and complete timed ophthalmic evaluation was performed. Specular microscopy was performed on all patients for endothelial cell count assessment and corneal thickness was measured by Pachymeter. The data was analyzed and represented using descriptive statistics. ‘t’ test was used for comparing the two groups.Results: The mean endothelial cell density in diabetic group was significantly lower (2438.73±250.23cells/mm2) compared to non-diabetic group (2599.88±168.16cells/mm2) (p<0.0001). The mean Central corneal thickness in diabetic group was significantly higher (518.40±28.13 μm) compared to control group (490.14±24.31 μm) (p<0.001). The Co-efficient of variation percentage of the diabetics was higher than the non-diabetics but this difference was not statistically significant (P>0.05). The hexagonality percentage was significantly lower in diabetic group compared to the controls suggesting less pleomorphism in the diabetic group.Conclusions: The study concludes that the endothelial cell density was lower and central corneal thickness was higher in diabetic patients compared with the non-diabetics. The altered endothelial morphology was significantly seen in the form of pleomorphism (hexagonality) but polymegathism was not significantly altered.


2020 ◽  
Author(s):  
Napaporn Tananuvat ◽  
Natawan Khumchoo

Abstract Background: This study aimed to determine the influence of age on central corneal thickness and corneal endothelial morphology as well as to identify the relationship between them in normal Thai eyes.Methods: Non-contact specular microscopy was performed in volunteers stratified into seven age groups ranging from 11-88 years. The corneal endothelial parameters studied included central corneal thickness (CCT), endothelial cell density (ECD), coefficient of variation in cell size (CV), cell area (CA) and percentage of regular hexagonal cells.Results: In a total of 501 subjects (1002 eyes), the mean age was 43.12 ± 18.80 years and 347(69.3%) were females. The mean CCT, ECD, CV, CA, and hexagonality was 533.80 ± 33.00 μm, 2,732±258 cell/mm2, 37.61 ± 6.76%, 369.04 ± 37.90 mm, and 49.03% ± 7.53%, respectively. There was a statistically significant inverse correlation between age and CCT (r = -0.212, P <0.001), ECD (r = -0.484, P <0.001), and hexagonality (r = -0.193, P <0.001). The estimate rate of endothelial cell loss was 0.2% per year, whereas CV and CA had statistically significant correlation with age (r = 0.200, P <0.001 and r = 0.475, P <0.001). CCT correlated directly with ECD (r = 0.177, P <0.001).Conclusion: Normative data for corneal endothelial morphology in healthy Thai eyes showed that ECD, CCT, and hexagonality were significantly decreased, while CV and CA were increased with aging. The central corneal thickness was correlated with the endothelial cell density.


2020 ◽  
Author(s):  
Tatsuya Jujo ◽  
Jiro Kogo ◽  
Hiroki Sasaki ◽  
Reio Sekine ◽  
Keiji Sato ◽  
...  

Abstract Backgrounds: However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. Methods Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o’clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. Results The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was − 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


Sign in / Sign up

Export Citation Format

Share Document