scholarly journals Comparing Four Video Laryngoscopes and One Optical Laryngoscope with a Standard Macintosh Blade in a Simulated Trapped Car Accident Victim

2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Florian J. Raimann ◽  
Daniel M. Tepperis ◽  
Dirk Meininger ◽  
Kai Zacharowski ◽  
Richard Schalk ◽  
...  

Background. Tracheal intubation still represents the “gold standard” in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant. Objectives. The aim of the study was to evaluate the performance and intubation success of four different video laryngoscopes, one optical laryngoscope, and a Macintosh blade while intubating from two different positions in a mannequin trial with difficult access to the patient. Methods. A mannequin with a cervical collar was placed on the driver’s seat. Intubation was performed with six different laryngoscopes either through the driver’s window or from the backseat. Success, C/L score, time to best view (TTBV), time to intubation (TTI), and number of attempts were measured. All participants were asked to rate their favored device. Results. Forty-two physicians participated. 100% of all intubations performed from the backseat were successful. Intubation success through the driver’s window was less successful. Only with the Airtraq® optical laryngoscope, 100% success was achieved. Best visualization (window C/L 2a; backseat C/L 2a) and shortest TTBV (window 4.7 s; backseat 4.1 s) were obtained when using the D-Blade video laryngoscope, but this was not associated with a higher success through the driver’s window. Fastest TTI was achieved through the window (14.2 s) when using the C-MAC video laryngoscope and from the backseat (7.3 s) when using a Macintosh blade. Conclusions. Video laryngoscopy revealed better results in visualization but was not associated with a higher success. Success depended on the approach and familiarity with the device. We believe that video laryngoscopy is suitable for securing airways in trapped accident victims. The decision for an optimal device is complicated and should be based upon experience and regular training with the device.

Author(s):  
Jürgen Knapp ◽  
Bettina Eberle ◽  
Michael Bernhard ◽  
Lorenz Theiler ◽  
Urs Pietsch ◽  
...  

Abstract Background Tracheal intubation remains the gold standard of airway management in emergency medicine and maximizing safety, intubation success, and especially first-pass intubation success (FPS) in these situations is imperative. Methods We conducted a prospective observational study on all 12 helicopter emergency medical service (HEMS) bases of the Swiss Air Rescue, between February 15, 2018, and February 14, 2019. All 428 patients on whom out-of-hospital advanced airway management was performed by the HEMS crew were included. The C-MAC video laryngoscope was used as the primary device for tracheal intubation. Intubation procedures were recorded by the video laryngoscope and precise time points were recorded to verify the time necessary for each attempt and the overall procedure time until successful intubation. The videos were further analysed for problems and complications during airway management by an independent reviewer. Additionally, a questionnaire about the intubation procedure, basic characteristics of the patient, circumstances, environmental factors, and the provider’s level of experience in airway management was filled out. Main outcome measures were FPS of tracheal intubation, overall success rate, overall intubation time, problems and complications of video laryngoscopy. Results FPS rate was 87.6% and overall success rate 98.6%. Success rates, overall time to intubation, and subjective difficulty were not associated to the providers’ expertise in airway management. In patients undergoing CPR FPS was 84.8%, in trauma patients 86.4% and in non-trauma patients 93.3%. FPS in patients with difficult airway characteristics, facial trauma/burns or obesity ranges between 87 and 89%. Performing airway management indoors or inside an ambulance resulted in a significantly higher FPS of 91.1% compared to outdoor locations (p < 0.001). Direct solar irradiation on the screen, fogging of the lens, and blood on the camera significantly impaired FPS. Several issues for further improvements in the use of video laryngoscopy in the out-of-hospital setting and for quality control in airway management were identified. Conclusion Airway management using the C-MAC video laryngoscope with Macintosh blade in a group of operators with mixed experience showed high FPS and overall rates of intubation success. Video recording emergency intubations may improve education and quality control.


Author(s):  
Özge Can ◽  
Sercan Yalcinli ◽  
Yusuf Ali Altunci

Introduction: Pre-hospital intubation is a challenging but essential intervention. During intubation, it is difficult to identify vocal cords when using a cervical collar and trauma board. Therefore, the success rate of intubation by paramedics decreases in trauma patients. Video laryngoscopy increases intubation success rate and has been recommended for difficult airways in studies. Objective: In this study, we compared the intubation success rates when using a video laryngoscope and a direct laryngoscope in a manikin with simulated cervical immobilization.  Methods: In this cross-sectional study, the manikin’s neck collar and spine board created a complicated airway model with cervical immobilization. Inexperienced paramedic students tried intubation with both methods, and their trial periods were recorded. Students answered a question evaluating the convenience of the procedure for both methods after the trial. Results: In this study, 83 volunteers, who were first-year and second-year paramedics, participated; 32 (38.6%) of the volunteers were first-year students, while 51 (61.4%) were second-year students. All volunteers had previous intubation experience with direct laryngoscopy, but not with video laryngoscopy. There was a statistically significant difference in the first-attempt success rates of the procedure between the groups in favor of video laryngoscope (p=0.022). Note that there was no significant difference between the groups in terms of first attempt durations (p=0.337). Conclusion: Video laryngoscopy in airway management can increase the success rate of first-attempt intubation by inexperienced pre-hospital healthcare personnel.


2012 ◽  
Vol 116 (3) ◽  
pp. 629-636 ◽  
Author(s):  
Michael F. Aziz ◽  
Dawn Dillman ◽  
Rongwei Fu ◽  
Ansgar M. Brambrink

Background Video laryngoscopy may be useful in the setting of the difficult airway, but it remains unclear if intubation success is improved in routine difficult airway management. This study compared success rates for tracheal intubation with the C-MAC® video laryngoscope (Karl Storz, Tuttlingen, Germany) with conventional direct laryngoscopy in patients with predicted difficult airway. Methods We conducted a two arm, single-blinded randomized controlled trial that involved 300 patients. Inclusion required at least one of four predictors of difficult intubation. The primary outcome was successful tracheal intubation on first attempt. Results The use of video laryngoscopy resulted in more successful intubations on first attempt (138/149; 93%) as compared with direct laryngoscopy (124/147; 84%), P = 0.026. Cormack-Lehane laryngeal view was graded I or II in 139/149 of C-MAC attempts versus 119/147 in direct laryngoscopy attempts (P &lt; 0.01). Laryngoscopy time averaged 46 s (95% CI, 40-51) for the C-MAC group and was shorter in the direct laryngoscopy group, 33 s (95% CI, 29-36), P &lt; 0.001. The use of a gum-elastic bougie and/or external laryngeal manipulation were required less often in the C-MAC intubations (24%, 33/138) compared with direct laryngoscopy (37%, 46/124, P = 0.020). The incidence of complications was not significantly different between the C-MAC (20%, 27/138) versus direct laryngoscopy (13%, 16/124, P = 0.146). Conclusion A diverse group of anesthesia providers achieved a higher intubation success rate on first attempt with the C-MAC in a broad range of patients with predictors of difficult intubation. C-MAC laryngoscopy seems to be a useful technique for the initial approach to a potentially difficult airway.


2020 ◽  
Author(s):  
Jürgen Knapp ◽  
Bettina Eberle ◽  
Michael Bernhard ◽  
Lorenz Theiler ◽  
Urs Pietsch ◽  
...  

Abstract Objective. Tracheal intubation remains the gold standard of airway management in emergency medicine and maximizing safety, intubation success and especially first-pass intubation success (FPS) in these situations is imperative.Methods. We conducted a prospective observational study on all twelve helicopter emergency medical service (HEMS) bases of the Swiss Air Rescue, between February 15, 2018, and February 14, 2019. All 428 patients on whom out-of-hospital advanced airway management was performed by the HEMS crew were included. The C-MAC video laryngoscope was used as primary device for tracheal intubation. Intubation procedures were recorded by the video laryngoscope and precise time points were recorded to verify the time necessary for each attempt and the overall procedure time until successful intubation. The videos were further analysed for problems and complications during airway management by an independent reviewer. Additionally, a questionnaire about the intubation procedure, basic characteristics of the patient, as well as circumstances and environmental factors, and the level of experience in airway management of the provider had to be filled out. Main outcome measures were FPS of tracheal intubation, overall success rate, overall intubation time, problems and complications of video laryngoscopy.Results. FPS rate was 87.6% and overall success rate 98.6%. Success rates, overall time to intubation, and subjective difficulty were not associated to the providers’ expertise in airway management. In patients undergoing CPR FPS was 84.8%, in trauma patients 86.4% and in non-trauma patients 93.3%. FPS in patients with difficult airway characteristics, facial trauma/burns or obesity ranges between 87 and 89%. Performing airway management indoors or inside an ambulance resulted in a significantly higher FPS of 91.1% compared to outdoor locations (p<0.001). Direct solar irradiation on the screen, fogging of the lens, and blood on the camera significantly impaired FPS. Several issues for further improvements in the use of video laryngoscopy in the out-of-hospital setting and for quality control in airway management were identified.Conclusion. Airway management using the C-MAC video laryngoscope with Macintosh blade in a group of operators with mixed experience showed high FPS and overall rates of intubation success. Video recording emergency intubations may improve education and quality control.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Bradley Boehringer ◽  
Michael Choate ◽  
Shelley Hurwitz ◽  
Peter V. R. Tilney ◽  
Thomas Judge

Accurate endotracheal intubation for patients in extremis or at risk of physiologic decompensation is the gold standard for emergency medicine. Field intubation is a complex process and time to intubation, number of attempts, and hypoxia have all been shown to correlate with increases in morbidity and mortality. Expanding laryngoscope technology which incorporates active video, in addition to direct laryngoscopy, offers providers improved and varied tools to employ in management of the advanced airway. Over a nine-year period a helicopter emergency medical services team, comprised of a flight paramedic and flight nurse, intended to intubate 790 patients. Comparative data analysis was performed and demonstrated that the introduction of the CMAC video laryngoscope improved nearly every measure of success in airway management. Overall intubation success increased from 94.9% to 99.0%, first pass success rates increased from 75.4% to 94.9%, combined first and second pass success rates increased from 89.2% to 97.4%, and mean number of intubation attempts decreased from 1.33 to 1.08.


2020 ◽  
Author(s):  
Souvik Maitra ◽  
Anirban Som ◽  
Sulagna Bhattacharjee

AbstractPurposeTo identify the benefit of video laryngoscope (VL) over direct laryngoscope (DL) for intubation in the intensive care unit (ICU)Material & MethodsRandomized controlled trials (RCTs) comparing VL with DL for intubation in ICU by was conducted in conventional frequentist methodology and also incorporated of the previous evidences from observational studies in Bayesian methodology.ResultsData of 1464 patients from six RCTs have been included in this meta-analysis. In conventional meta-analysis of RCTs, first attempt intubation success rate was similar between VL and DL group [p=0.39]. Rate of esophageal intubation was significantly less with VL [p=0.03] and glottic visualization was significantly improved with VL in comparison to DL [p=0.009]. Time to intubation was similar in both the group [p=0.48]. When evidences from a meta-analysis of observational studies incorporated in Bayesian model, first attempt intubation success is significantly higher with VL [posterior median log OR (95% credible interval) 0.50 (0.06, 1.00)].ConclusionEvidences from both observational studies and RCTs synthesized in Bayesian methodology suggest that use of VL for endotracheal intubation in critically patients may be associated with higher first intubation success when compared to DL.


2020 ◽  
Vol 46 (5) ◽  
pp. 1039-1045 ◽  
Author(s):  
Wim Breeman ◽  
Mark G. Van Vledder ◽  
Michael H. J. Verhofstad ◽  
Albert Visser ◽  
Esther M. M. Van Lieshout

Abstract Purpose The aim of this study was to compare the rate of first attempt success of endotracheal intubation performed by ambulance nurses in patients with a Glasgow Coma Scale (GCS)  of 3 using video laryngoscopy versus direct laryngoscopy. Methods A prospective cohort study was conducted in a single, independent ambulance service. Twenty of a total of 65 nurse-staffed ambulances were equipped with a video laryngoscope; a classic direct laryngoscope (Macintosh) was available on all 65 ambulances. The primary outcome was first attempt success of the intubation. Secondary outcomes were overall success, time needed for intubation, adverse events, technical or environmental issues encountered, and return of spontaneous circulation (ROSC). Ambulance nurses were asked if the intubation device had affected the outcome of the intubation. Results The first attempt success rate in the video laryngoscopy group [53 of 93 attempts (57%)] did not differ from that in the direct laryngoscopy group [61 of 126 (48%); p = 0.221]. However, the second attempt success rate was higher in the video laryngoscopy group [77/93 (83%) versus 80/126 (63%), p = 0.002]. The median time needed for the intubation (53 versus 56 s) was similar in both groups. Ambulance nurses more often expected a positive effect when performing endotracheal intubation with a video laryngoscope (n = 72, 81%) compared with a direct laryngoscope (n = 49, 52%; p < 0.001). Conclusion Although no significant effect on the first attempt success was found, video laryngoscopy did increase the overall success rate. Ambulance nurses had a more positive valuation of the video laryngoscope with respect to success chances.


2009 ◽  
Vol 24 (3) ◽  
pp. 265-270 ◽  
Author(s):  
Lars P. Bjoernsen ◽  
Bruce Lindsay

AbstractIn the prehospital setting, the emergency care provider must anticipate that some patients will manifest with difficult airways. The use of video laryngoscopy to secure an airway in the prehospital setting has not been explored widely, but has the potential to be a useful tool. This article briefly reviews some of the major video laryngoscopes on the market and their usefulness in the prehospital setting. Studies and case reports indicate that the video laryngoscope is a promising device for emergency intubation, and it has been predicted that, in the future, video laryngoscopy will dominate the field of emergency airway management.Direct laryngoscopy always should be retained as a primary skill; however, the video laryngoscope has the potential to be a good primary choice for the patient with potential cervical spine injuries or limited jaw or spine mobility, and in the difficult-to-access patient.The role of video laryngoscopes in securing an airway in head and neck trauma victims in the prehospital setting has yet to be determined, but offers interesting possibilities. Further clinical studies are necessary to evaluate its role in airway management by prehospital emergency medical services.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Joni E. Rabiner ◽  
Marc Auerbach ◽  
Jeffrey R. Avner ◽  
Dina Daswani ◽  
Hnin Khine

Objective. To compare novice clinicians’ performance using GlideScope videolaryngoscopy (GVL) to direct laryngoscopy (DL).Methods. This was a prospective, randomized crossover study. Incoming pediatric interns intubated pediatric simulators in four normal and difficult airway scenarios with GVL and DL. Primary outcomes included time to intubation and rate of successful intubation. Interns rated their satisfaction of the devices and chose the preferred device.Results. Twenty-five interns were included. In the normal airway scenario, there were no differences in mean time for intubation with GVL or DL (61.4 versus 67.4 seconds, ) or number of successful intubations (19 versus 18, ). In the difficult airway scenario, interns took longer to intubate with GVL than DL (87.7 versus 61.3 seconds, ), but there were no differences in successful intubations (14 versus 15, ). There was a trend towards higher satisfaction for GVL than DL (7.3 versus 6.4, ), and GVL was chosen as the preferred device by a majority of interns (17/25, 68%).Conclusions. For novice clinicians, GVL does not improve time to intubation or intubation success rates in a pediatric simulator model of normal and difficult airway scenarios. Still, these novice clinicians overall preferred GVL.


Sign in / Sign up

Export Citation Format

Share Document