The Accuracy of Hemoglobin A1c and Fructosamine Evaluated by Long-Term Continuous Glucose Monitoring in Patients with Type 2 Diabetes Undergoing Hemodialysis

2021 ◽  
pp. 1-9
Author(s):  
Tobias Bomholt ◽  
Marianne Rix ◽  
Thomas Almdal ◽  
Filip K. Knop ◽  
Susanne Rosthøj ◽  
...  

<b><i>Introduction:</i></b> The accuracy of hemoglobin A1c (HbA1c) as a glycemic marker in patients with type 2 diabetes (T2D) receiving hemodialysis (HD) remains unknown. To assess accuracy, we compared HbA1c and fructosamine levels with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with T2D receiving HD. <b><i>Methods:</i></b> Thirty patients in the HD group and 36 patients in the control group (T2D and an estimated glomerular filtration rate &#x3e;60 mL/min/1.73 m<sup>2</sup>) completed the study period of 17 weeks. CGM (Ipro2<sup>®</sup>, Medtronic) was performed 5 times for periods of up to 7 days (with 4-week intervals) during a 16-week period. HbA1c (mmol/mol), the estimated mean plasma glucose from HbA1c (eMPGA1c [mmol/L]) and fructosamine (μmol/L) was measured at week 17 and compared with mean sensor glucose levels from CGM. <b><i>Findings:</i></b> In the HD group, mean sensor glucose was 1.4 mmol/L (95% confidence interval [CI]: 1.0–1.8) higher than the eMPGA1c, whereas the difference for controls was 0.1 mmol/L (95% CI: −0.1–[0.4]; <i>p</i> &#x3c; 0.001). Adjusted for mean sensor glucose, HbA1c was lower in the HD group (−7.3 mmol/mol, 95% CI: −10.0–[−4.7]) than in the control group (<i>p</i> &#x3c; 0.001), with no difference detected for fructosamine (<i>p</i> = 0.64). <b><i>Discussion:</i></b> HbA1c evaluated by CGM underestimates plasma glucose levels in patients receiving HD. The underestimation represents a clinical challenge in optimizing glycemic control in the HD population. Fructosamine is unaffected by the factors affecting HbA1c and appears to be more accurate for glycemic monitoring. CGM or fructosamine could thus complement HbA1c in obtaining more accurate glycemic control in this patient group.

Nephron ◽  
2021 ◽  
pp. 1-7
Author(s):  
Tobias Bomholt ◽  
Bo Feldt-Rasmussen ◽  
Rizwan Butt ◽  
Rikke Borg ◽  
Mir Hassan Sarwary ◽  
...  

<b><i>Introduction:</i></b> Shortened erythrocyte life span and erythropoietin-stimulating agents may affect hemoglobin A<sub>1c</sub> (HbA<sub>1c</sub>) levels in patients receiving peritoneal dialysis (PD). We compared HbA<sub>1c</sub> with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with type 2 diabetes receiving PD. <b><i>Methods:</i></b> Fourteen days of CGM (Ipro2, Medtronic) were performed in 23 patients with type 2 diabetes receiving PD and in 23 controls with type 2 diabetes and an estimated glomerular filtration rate over 60 mL/min/1.73 m<sup>2</sup>. Patients were matched on gender and age (±5 years). HbA<sub>1c</sub> (mmol/mol), its derived estimate of mean plasma glucose (eMPG<sub>A1c</sub>) (mmol/L), and fructosamine (µmol/L) were measured at the end of the CGM period and compared with the mean sensor glucose (mmol/L) from CGM. <b><i>Results:</i></b> In the PD group, mean sensor glucose was 0.98 (95% con­fidence interval (CI): 0.43–1.54) mmol/L higher than the eMPG<sub>A1c</sub> compared with the control group (<i>p</i> = 0.002) where glucose levels were nearly identical (−0.05 (95% CI: −0.35–0.25) mmol/L). A significant association was found between fructosamine and mean sensor glucose using linear regression with no difference between slopes (<i>p</i> = 0.89) or y-intercepts (<i>p</i> = 0.28). <b><i>Discussion/Conclusion:</i></b> HbA<sub>1c</sub> underestimates mean plasma glucose levels in patients with type 2 diabetes receiving PD. However, the clinical significance of this finding is undetermined. Fructosamine seems to more accurately reflect glycemic status. CGM or fructosamine could complement HbA<sub>1c</sub> to increase the accuracy of glycemic monitoring in the PD population.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Dulce Adelaida Rivera-Ávila ◽  
Alejandro Iván Esquivel-Lu ◽  
Carlos Rafael Salazar-Lozano ◽  
Kyla Jones ◽  
Svetlana V. Doubova

Abstract Background The study objective was to evaluate the effects of professional continuous glucose monitoring (CGM) as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes (T2D). Methods We conducted a three-month quasi-experimental study with an intervention (IGr) and control group (CGr) and ex-ante and ex-post evaluations in one family medicine clinic in Mexico City. Participants were T2D patients with HbA1c > 8% attending a comprehensive diabetes care program. In addition to the program, the IGr wore a professional CGM sensor (iPro™2) during the first 7 days of the study. Following this period, IGr participants had a medical consultation for the CGM results and treatment adjustments. Additionally, they received an educational session and personalized diet plan from a dietitian. After 3 months, the IGr again wore the CGM sensor for 1 week. The primary outcome variable was HbA1c level measured at baseline and 3 months after the CGM intervention. We analyzed the effect of the intervention on HbA1c levels by estimating the differences-in-differences treatment effect (Diff-in-Diff). Additionally, baseline and three-month CGM and dietary information were recorded for the IGr and analyzed using the Student’s paired t-test and mixed-effects generalized linear models to control for patients’ baseline characteristics. Results Overall, 302 T2D patients participated in the study (IGr, n = 150; control, n = 152). At the end of the three-month follow-up, we observed 0.439 mean HbA1C difference between groups (p = 0.004), with an additional decrease in HbA1c levels in the IGr compared with the CGr (Diff-in-Diff HbA1c mean of − 0.481% points, p = 0.023). Moreover, compared with the baseline, the three-month CGM patterns showed a significant increase in the percentage of time in glucose range (+ 7.25; p = 0.011); a reduction in the percentage of time above 180 mg/dl (− 6.01; p = 0.045), a decrease in glycemic variability (− 3.94, p = 0.034); and improvements in dietary patterns, shown by a reduction in total caloric intake (− 197.66 Kcal/day; p = 0.0001). Conclusion Professional CGM contributes to reducing HbA1c levels and is an adjuvant educational tool that can improve glycemic control in patients with T2D. Trial registration ClinicalTrials.gov: NCT04667728. Registered 16/12/2020


2021 ◽  
Vol 36 (Supplement_1) ◽  
Author(s):  
Tobias Bomholt ◽  
Marianne Rix ◽  
Thomas Peter Almdal ◽  
Filip K Knop ◽  
Susanne Rosthøj ◽  
...  

Abstract Background and Aims The reliability of haemoglobin A1c (HbA1c) as a glycaemic marker in patients receiving haemodialysis (HD) remains unknown. To assess accuracy, we compared HbA1c and fructosamine levels with interstitial glucose levels measured by continuous glucose monitoring (CGM) in patients with type 2 diabetes receiving HD. Method The HD group (maintenance HD and type 2 diabetes) comprised 30 patients who completed the study period of 17 weeks; the control group (type 2 diabetes and an estimated glomerular filtration rate &gt;60 mL/min/1.73 m2) comprised 36 individuals. CGM (Ipro2®, Medtronic) for periods up to seven days was performed five times (with four weeks intervals) during a 16-week period. HbA1c and fructosamine were measured at week 17. The mean sensor glucose from CGM was compared with the measured HbA1c, its estimated mean blood glucose (eMBGA1c) and fructosamine levels. Results In the HD group, the mean sensor glucose from CGM was 1.4 (95% confidence interval [CI]: 1.0–1.8) mmol/L higher than the eMBGA1c, whereas the difference was 0.1 mmol/L (95% CI: -0.1–[0.4]; P&lt;0.001) in the control group. Adjusted for the mean sensor glucose, HbA1c was -7.3 (95% CI: -10.0–[-4.7]) mmol/mol lower in the HD group than in controls (P&lt;0.001), whereas no difference was detected for fructosamine (P=0.64). Conclusion HbA1c evaluated by CGM underestimates mean blood glucose levels in patients receiving maintenance HD; fructosamine appears to be more accurate. CGM-assessed blood glucose could complement or replace HbA1c in patients where HbA1c underestimates blood glucose levels.


Diabetes ◽  
2020 ◽  
Vol 69 (Supplement 1) ◽  
pp. 2180-PUB
Author(s):  
ADDIE L. FORTMANN ◽  
ALESSANDRA BASTIAN ◽  
CODY J. LENSING ◽  
SHANE HOVERSTEN ◽  
KIMBERLY LUU ◽  
...  

JAMA ◽  
2021 ◽  
Vol 326 (13) ◽  
pp. 1330
Author(s):  
Wellbert Hernández-Núñez ◽  
Jesús Zacarías Villareal-Pérez ◽  
René Rodríguez-Gutiérrez

2020 ◽  
Author(s):  
Sérgio Vencio ◽  
Isabela Caiado-Vencio ◽  
Adriana Caiado ◽  
Douglas Morgental ◽  
Luisa Soares Dantas ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document