scholarly journals Voltage Instability of Initiation Fault Duration as Influenced by Nodes Short Circuit Levels NSCL with Different Types of Loads

Author(s):  
Youssef Ahmed Mobarak ◽  
Mahmoud M. Hussein

The occurrence of voltage instabilities or voltage collapses depend on the duration of the persistence of the fault and on the type of fault, some faults lead to voltage instabilities, others lead to voltage collapse. Evaluation of fault durations causing occurrence of voltage instabilities is the main goal of this paper. This paper searches for the effect of nodes short circuit levels NSCL and its duration periods initiation of voltage instability, with lagging and leading load power factors at certain loads buses. In this paper, the power system dynamic simulation program is developed for dynamic analysis of voltage stability. This paper is concerned with the fault duration which lead to the occurrence of voltage instability phenomena due to NSCL. The fault which lead to voltage instability is found to be short circuits at certain nodes cleared without any variation in the transmission system elements, i.e. the post-fault conditions will be the same as the pre-fault conditions. Models for loads considered in this study are induction motors with three different shaft mechanical loads, constant impedance CZ loads, constant current CI loads and constant power CP loads are used, as they depict the behavior of most power system loads. The influence of the transmission network impedances, which are nearly the inverse of the NSCL, on the fault duration which lead to the occurrence of voltage instabilities are studied and evaluated using various load representations.<strong><em></em></strong>

Author(s):  
Youssef Ahmed Mobarak ◽  
Mahmoud M. Hussein

The occurrence of voltage instabilities or voltage collapses depend on the duration of the persistence of the fault and on the type of fault, some faults lead to voltage instabilities, others lead to voltage collapse. Evaluation of fault durations causing occurrence of voltage instabilities is the main goal of this paper. This paper searches for the effect of nodes short circuit levels NSCL and its duration periods initiation of voltage instability, with lagging and leading load power factors at certain loads buses. In this paper, the power system dynamic simulation program is developed for dynamic analysis of voltage stability. This paper is concerned with the fault duration which lead to the occurrence of voltage instability phenomena due to NSCL. The fault which lead to voltage instability is found to be short circuits at certain nodes cleared without any variation in the transmission system elements, i.e. the post-fault conditions will be the same as the pre-fault conditions. Models for loads considered in this study are induction motors with three different shaft mechanical loads, constant impedance CZ loads, constant current CI loads and constant power CP loads are used, as they depict the behavior of most power system loads. The influence of the transmission network impedances, which are nearly the inverse of the NSCL, on the fault duration which lead to the occurrence of voltage instabilities are studied and evaluated using various load representations.<strong><em></em></strong>


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 117
Author(s):  
Marcin Tomczyk ◽  
Ryszard Mielnik ◽  
Anna Plichta ◽  
Iwona Goldasz ◽  
Maciej Sułowicz

This paper presents a method of inter-turn short-circuit identification in induction motors during load current variations based on a hybrid analytic approach that combines the genetic algorithm and simulated annealing. With this approach, the essence of the method relies on determining the reference matrices and calculating the distance between the reference matric values and the test matrix. As a whole, it is a novel approach to the process of identifying faults in induction motors. Moreover, applying a discrete optimization algorithm to search for alternative solutions makes it possible to obtain the true minimal values of the matrices in the identification process. The effectiveness of the applied method in the monitoring and identification processes of the inter-turn short-circuit in the early stage of its creation was confirmed in tests carried out for several significant state variables describing physical magnitudes of the selected induction motor model. The need for identification of a particular fault is related to a gradual increase in its magnitude in the process of the induction motor’s exploitation. The occurrence of short-circuits complicates the dynamic properties of the measured diagnostic signals of the system to a great extent.


2020 ◽  
Vol 14 (1) ◽  
pp. 21-26
Author(s):  
S. SKRYPNYK ◽  
◽  
A. SHEINA ◽  

Most failures in electrical installations are caused by short circuits (short circuits), which occur as a result of a failure in the electrical strength of the insulation of the conductive parts. A short circuit is an electrical connection of two points of an electric circuit with different values of potential, which is not provided by the design of the device, which interferes with its normal operation. Short circuits may result from a failure of the insulation of the current-carrying elements or the mechanical contact of the non- insulated elements. Also called a short circuit is a condition where the load resistance is less than the internal resistance of the power source. The reasons for such violations are various: aging of insulation, breakages of wires of overhead transmission lines, mechanical damages of isolation of cable lines at ground works, lightning strikes in the transmission line and others. Most often, short-circuits occur through transient resistance, such as through the resistance of an electric arc that occurs at the point of damage to the insulation. Sometimes there are metallic short circuits in which the resistance of the electric arc is very small. The study of short circuits in the power grid is a major step in the design of modern electrical networks. The research is conducted using computer software, first by modeling the system and then simulating errors. A malfunction usually leads to an increase in the current flowing in the lines, and failure to provide reliable protection can result in damage to the power unit. Thus, short-circuit calculations are the primary consideration when designing, upgrading, or expanding a power system. The three-phase short circuit is the least likely. However, in many cases, the three-phase short circuit is associated with the most severe consequences, as it causes the highest power imbalances on the shafts of the generators. The study of transients begins with the mode of three-phase closure due to its relative simplicity in comparison with other types of asymmetry. In most cases, the analysis and calculation of the transient regime of the electrical system involves the preparation of a calculated scheme of substitution, in which the parameters of its elements are determined in named or relative units. The electrical substitution circuitry is used to further study the transients in the power system. The definition of electrical and electromagnetic quantities in relative units is widely used in the theory of electric machines. This is because it significantly simplifies the theoretical calculations and gives the results a generalized view in the practical calculations of currents and residual voltages at the short circuit. By the relative value of any value is understood as its relation to another value of the same name, taken as the base. So, before presenting any quantities in relative units, we need to choose the basic units. In the electrical system with increased voltages, the overall load capacity of the network increases, which in turn makes it possible to supply high-quality electrical energy over a greater distance. In the process of comparing the type of transmission lines, it should be noted that the advantages of the cable transmission line. According to the results of the calculation of short-circuit currents, it can be concluded that in networks with a larger line cross-section and a higher voltage, the short-circuit currents are larger. Thus, during the transition of the electric networks to the higher voltage class of 20 kV, the currents of the KZ increased by 43% compared to the 6 kV electric network. This analysis shows that the importance of reliable power supply in the power supply system for high voltage classes must be high and have equipment to prevent emergencies. In the future, it is planned to develop a systematic calculation of short-circuit currents for a number of transmission lines and to conduct mathematical modeling in the system of applications for the study of transient processes at short circuits.


2013 ◽  
Vol 433-435 ◽  
pp. 705-708 ◽  
Author(s):  
Shuo Ding ◽  
Xiao Heng Chang ◽  
Qing Hui Wu

In fault diagnosis of three-phase induction motors, traditional methods usually fail because of the complex system of three-phase induction motors. Short circuit is a very common stator fault in all the faults of three-phase induction motors. Probabilistic neural network is a kind of artificial neural network which is widely used due to its fast training and simple structure. In this paper, the diagnosis method based on probabilistic neural network is proposed to deal with stator short circuits. First, the principle and structure of probabilistic neural network is studied in this paper. Second, the method of fault setting and fault feature extraction of three-phase induction motors is proposed on the basis of the fault diagnosis of stator short circuits. Then the establishment of the diagnosis model based on probabilistic neural network is illustrated with details. At last, training and simulation tests are done for the model. And simulation results show that this method is very practical with its high accuracy and fast speed.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8523
Author(s):  
Marcin Tomczyk ◽  
Ryszard Mielnik ◽  
Anna Plichta ◽  
Iwona Gołdasz ◽  
Maciej Sułowicz

This paper presents a new method of inter-turn short-circuit detection in cage induction motors. The method is based on experimental data recorded during load changes. Measured signals were analyzed using a genetic algorithm. This algorithm was next used in the diagnostics procedure. The correctness of fault detection was verified during experimental tests for various configurations of inter-turn short-circuits. The tests were run for several relevant diagnostic signals that contain symptoms of faults in an examined cage induction motor. The proposed algorithm of inter-turn short-circuit detection for various levels of winding damage and for various loads of the examined motor allows one to state the usefulness of this diagnostic method in normal industry conditions of motor exploitation.


2021 ◽  
Author(s):  
Ankitkumar Naik

This report provides review of importance of power system protection and presents different techniques available in practical situations. The material provided in this report is available online on different resources. Moreover, this report examines different types of faults in power system and discusses the consequences of the faults. Moreover, it also talks about different methods of protection schemes applied for various faults occurred on power system equipment such as transformer, generator, bus, transmission and distribution lines and motors. Furthermore, different relaying techniques are also discussed briefly which are used extensively throughout the report for explaining the importance of these techniques in fault detection and damage prevention. SKM power tool is used for simulation purpose. The simulation result are displayed and explained. Moreover, short circuit calculation and equipment selection method is also discussed in this report.


2013 ◽  
Vol 10 (3) ◽  
pp. 445-457
Author(s):  
Ali Behniafar ◽  
Ahmad Darabi ◽  
Mahdi Banejad ◽  
Mohammadreza Baghayipour

The electric marine instruments are newly inserted in the trade and industry, for which the existence of an equipped and reliable power system is necessitated. One of the features of such a power system is that it cannot have an earth system causing the protection relays not to be able to detect the single line to ground short circuit fault. While on the other hand, the occurrence of another similar fault at the same time can lead to the double line fault and thereby the tripping of relays and shortening of vital loads. This in turn endangers the personals' security and causes the loss of military plans. From the above considerations, it is inferred that detecting the single line to ground fault in the marine instruments is of a special importance. In this way, this paper intends to detect the single line to ground fault in the power systems of the marine instruments using the wavelet transform and Multi-Layer Perceptron (MLP) neural network. In the numerical analysis, several different types of short circuit faults are simulated on several marine power systems and the proposed approach is applied to detect the single line to ground fault. The results are of a high quality and preciseness and perfectly demonstrate the effectiveness of the proposed approach.


Author(s):  
Fatima Babaa ◽  
Ouafae Bennis

Safety, disponibility and continuity of industrial systems are major issue in maintenance. In the last decades, these points are the important axes in the field of research. In fact, in many industrial processes research has picked up a fervent place and a particular importance in the area of fault diagnosis of electrical machines, in fact, a fault prognosis has become almost indispensable. The need of a mathematical model of three-phase induction machine, suitable for the simulation of machines behaviour under fault conditions, has received considerable attention. The paper presents a new practical and more precise model for induction motors after introducing inter turn short circuits faults. The proposed model is based on coupled magnetic circuit theory, capable to take into account any electrical asymmetry conditions. To verify the exactitude and the effectiveness of the model, simulation results for induction machine under interturn short circuit fault are presented. In spite of its simplicity, the proposed model is able to provide useful indications for diagnostic purposes. Experimental study is presented at the end of the paper to show that the proposed model predicts the induction machine behavior with a good accuracy.


2021 ◽  
Author(s):  
Ankitkumar Naik

This report provides review of importance of power system protection and presents different techniques available in practical situations. The material provided in this report is available online on different resources. Moreover, this report examines different types of faults in power system and discusses the consequences of the faults. Moreover, it also talks about different methods of protection schemes applied for various faults occurred on power system equipment such as transformer, generator, bus, transmission and distribution lines and motors. Furthermore, different relaying techniques are also discussed briefly which are used extensively throughout the report for explaining the importance of these techniques in fault detection and damage prevention. SKM power tool is used for simulation purpose. The simulation result are displayed and explained. Moreover, short circuit calculation and equipment selection method is also discussed in this report.


Author(s):  
Ming-Jong Lin

The short circuit current of the equipment must be carefully calculated. If it is not effective to isolate the fault point, while the system is abnormal. That will leads to prolonged fault time and the instability of power system. The calculation process is very so complicated that must to establish any capacity of equipment on system. This article will introduce method of the traditional algorithm beginning. Next, to establish the basic principles of simplified procedures such as the capacity of two parallel devices are considered as a series method (plus), but the capacity of two series devices are considered as a parallel method to calculate. Finally, to calculate the fault short-circuits current based on the actual equipment capacity on the power system. Another technique is to transform the structure of transmission line from △ to Y so that it easy to simplify for calculation. It is proved to be a simple and easy to understand what method for short circuit fault current of calculation. The method can provide accurate and effective calculation of system short circuit capacity and current at each equipment point, so that designer can make appropriate specifications in design and procurement to avoid wasteful investment.