Circulating microparticles: challenges and perspectives of flow cytometric assessment

2014 ◽  
Vol 111 (06) ◽  
pp. 1009-1014 ◽  
Author(s):  
Eduard Shantsila ◽  
Silvia Montoro-García ◽  
Pilar Gallego ◽  
Gregory Y. H. Lip

SummaryCirculating blood microparticles are likely to play a significant role as messengers of biological information. Their accurate quantification and characterisation is challenging and needs to be carefully designed with preferable usage of fresh minimally-processed blood samples. Utilisation of flow cytometers specifically designed for analysis of small-size particles is likely to provide considerable methodological advantages and should be the preferable option. This viewpoint manuscript provides a critical summary of the key methodological aspects of microparticle analysis.Note: The review process for this viewpoint article was fully handled by Christian Weber, Editor in Chief.

Blood ◽  
1990 ◽  
Vol 75 (1) ◽  
pp. 116-121 ◽  
Author(s):  
J Kienast ◽  
G Schmitz

Thiazole orange (TO), a fluorescent dye originally synthesized for reticulocyte analysis, is characterized by a large fluorescence enhancement and high quantum yield on binding to nucleic acids, particularly RNA. In addition, the dye readily permeates live cell membranes. We applied TO staining, followed by fluorescence-activated flow cytometric analysis, to platelets in whole blood samples from hematologically normal subjects and patients with various quantitative platelet disorders. The percentage of TO-positive platelets in 50 control subjects was 8.6 +/- 2.8% (mean +/- SD) ranging from 2.8% to 15.8%. In 21 thrombocytopenic patients whose bone marrow contained normal to increased numbers of megakaryocytes, the percentage of fluorescently labeled platelets was significantly elevated (P less than .0001) to 26.9 +/- 10.9% (range, 13.3% to 57.1%). In contrast, the proportion of positively stained platelets in 23 patients with thrombocytopenia due to impaired platelet production (various conditions with reduced marrow megakaryocytes) did not significantly differ from the controls, whereas the absolute counts of TO-positive platelets were significantly lowered (P less than .0001). Differences in the distributions of the percentage values as well as of the absolute counts for TO-positive platelets between the two patient groups were again highly significant (P less than .0001). Both the sensitivity and the specificity of this method in distinguishing between these categories of thrombocytopenia were greater than or equal to 95%. We conclude that flow cytometric analysis of platelets after staining with TO is a sensitive and specific test that rapidly provides information on the thrombopoietic activity in thrombocytopenic disorders. Our data further suggest that increased amounts of residual RNA characterize platelets released under conditions of “stress thrombopoiesis.”


1994 ◽  
Vol 87 (5) ◽  
pp. 575-580 ◽  
Author(s):  
Nicolas A. F. Chronos ◽  
Darren J. Wilson ◽  
Sarah L. Janes ◽  
Ronald A. Hutton ◽  
Nigel P. Buller ◽  
...  

1. Aspirin inhibits the conversion of arachidonic acid to thromboxane A2 which reinforces the effects of weak agonists such as ADP in platelets. 2. In this study the effect of aspirin (300 mg/day) on platelet agonist response was measured by whole blood flow cytometry of unfixed blood samples from normal subjects (n = 10), an assay that investigates aggregation-independent changes in the platelet. 3. Fibrinogen binding to unstimulated platelets or to platelets stimulated with ADP or thrombin was unaffected by aspirin. 4. Under the conditions of this assay, platelets undergo a partial degranulation of α-granules and lysosomes (evidenced by expression of P-selectin and CD63, respectively) in response to ADP, and full degranulation in response to thrombin. P-selectin expression was paralleled by release of β-thromboglobulin. None of these events was affected by aspirin. 5. Thromboxane formation was totally prevented by the aspirin treatment, as shown by Born aggregometry in which the platelet aggregatory response to arachidonic acid was abolished and secondary aggregation by ADP was inhibited. 6. The flow cytometric assay can therefore be used to investigate platelets in patients, regardless of aspirin therapy. 7. These findings suggest that platelet fibrinogen binding and the release of platelet α-granule and lysosomal contents, in response to stimulation with physiological agonists, can continue in patients despite aspirin therapy. This may help to explain why aspirin is only partially effective in preventing thrombotic events.


Author(s):  
Alan R. Morrison ◽  
Joseph C. Wu ◽  
Mehran M. Sadeghi

Cardiovascular molecular imaging is a relatively young but rapidly expanding discipline that consists of a biologically-targeted approach to the assessment of physiologic and pathologic processes in vivo. This novel approach to imaging involves the integration of multiple disciplines such as cell and molecular biology, chemistry, and imaging sciences. The ultimate goal is quantitative assessment of cardiovascular processes at the cellular and molecular level, moving beyond traditional diagnostic information, in order to guide individually tailored therapy. In fact, it is likely that specific approaches to molecular imaging will be developed in tandem with the development of novel therapeutic strategies. Recent advances in probe development and imaging systems have contributed to evolution of molecular imaging toward clinical translational. These include technological progress in traditional imaging platforms; along with the emergence of newer imaging modalities such as photoacoustic imaging. In addition, hybrid imaging (e.g. nuclear imaging with CT or MRI) has the potential for improved spatial localization, and more accurate quantification by coupling anatomic and biological information. In addition to potential clinical applications that address existing diagnostic gaps in cardiovascular medicine, molecular imaging allows for unique approaches to studying pathophysiology. This chapter is intended to provide an overview of the state of the art in cardiovascular molecular imaging, highlighting how it may improve the management of major cardiovascular diseases.


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 3099-3099 ◽  
Author(s):  
Thomas Porturas ◽  
Mary Sell ◽  
Leah Irwin ◽  
Una O'Doherty ◽  
Carlos Hipolito Villa

Abstract Background: Although peripheral blood CD34+ stem cell counts by flow cytometry correlate well with yields, the time, complexity, and cost associated with flow cytometry limits its utility. Rapid, cost-effective, surrogate predictors (with <1hr turnaround) would allow for same-visit analyses and alteration of collection and mobilization strategies, particularly for the optimal use of time-sensitive and costly agents such as plerixafor. We previously demonstrated that morphologic parameters of neutrophil-like cells measured by hematology analyzers correlated with CD34 counts. We aimed to improve these models by using multiple regression analyses on data from a common hematology analyzer. Methods: Patients undergoing stem cell apheresis were evaluated over a 6 month period. The day prior to initiation of apheresis, and on the morning of initial collection, peripheral blood samples were drawn into EDTA collection tubes and flow cytometric CD34 measurement and/or CBCs were performed on the Beckman Coulter DxH 800 hematology analyzer per standard protocol. CD34 cells were counted by flow cytometric ISHAGE protocols. Data from the DxH (48 variables per specimen) were exported into a data matrix with the corresponding flow cytometric data. Multiple regression analysis was performed using a step-wise method with log(peripheral CD34) as the dependent variable (SPSS, IBM). Data were randomly selected into a training-set of 70% of cases and a test-set of 30% of cases for validation. The derived model was further tested against peripheral blood data from the morning of collection to predict harvest yields. Further analyses were performed using Prism (GraphPad). Results: Tandem peripheral blood CD34 counts and CBC cell-population data were obtained from 69 blood samples in 64 patients. The population included patients with multiple myeloma (45), non-Hodgkin lymphoma (12), Hodgkin lymphoma (5), and amyloidosis (2). 41% of patients were female. In the test data set examining collection yields, 37 patients were mobilized with GCSF (+/- chemotherapy) alone, while 17 had plerixafor added to the regimen. 33 of these patients had same-day CBC data available for model prediction. The median processed volume was 15 L (range 5.9 to 19.7). The model to predict peripheral CD34 counts incorporated 3 variables from the hematology analyzer data (SD-V-EGC, SD-C-EGC, and NE#). Interestingly, the model included two variables descriptive of the morphology of early granulocytic cells. The model demonstrated an R value of 0.829 (adjusted R2 = 0.670, figure 1a). In testing the morning-of-collection model-predicted peripheral CD34, we found the model performed similarly to flow cytometry in predicting 1st collection yields. Furthermore, the CD34 prediction using the model (Figure 1 b) resulted in similar correlation with first-collection yields in patients treated with plerixafor versus patients not treated with plerixafor, in contrast to day-prior CD34 counts by flow-cytometry (Figure 1c). Two outliers for CD34 cell yield based on model predicted peripheral CD34 were identified. In one patient, the processed volume was very low (6.8 L, <5% percentile), while the second had a low mononuclear cell collection efficiency (35%) compared to the mean in this population (58.7%±23.3%). Threshold values for the model accurately identified patients appropriate for collection initiation (or plerixafor administration). Conclusion: Using data from a common, automated CBC analyzer, we developed a rapid, less-costly, and simple model to predict CD34 cell counts and 1st harvest yields. Because the measurement results can be obtained within the same clinic visit, and can be repeated with each CBC, the model is particularly useful to guide optimal use of plerixafor. We also envision that the model is useful for quality assurance of collection by identifying patients in whom cell yields were sub-optimal with respect to predicted CD34 cell counts. Additional studies to test the model in a larger population are ongoing. We propose that this model (and similarly derived models) can be implemented in clinical planning algorithms to improve the efficiency and cost of stem cell collection by apheresis. Acknowledgments: We would like to acknowledge and the nurses and staff of the apheresis unit and the stem cell and flow cytometry laboratories at the Hospital of the University of Pennsylvania for their contributions. Figure 1. Figure 1. Disclosures No relevant conflicts of interest to declare.


2010 ◽  
Vol 77A (6) ◽  
pp. 502-514 ◽  
Author(s):  
Aaron F. Orozco ◽  
Dorothy E. Lewis

Blood ◽  
1990 ◽  
Vol 75 (1) ◽  
pp. 116-121 ◽  
Author(s):  
J Kienast ◽  
G Schmitz

Abstract Thiazole orange (TO), a fluorescent dye originally synthesized for reticulocyte analysis, is characterized by a large fluorescence enhancement and high quantum yield on binding to nucleic acids, particularly RNA. In addition, the dye readily permeates live cell membranes. We applied TO staining, followed by fluorescence-activated flow cytometric analysis, to platelets in whole blood samples from hematologically normal subjects and patients with various quantitative platelet disorders. The percentage of TO-positive platelets in 50 control subjects was 8.6 +/- 2.8% (mean +/- SD) ranging from 2.8% to 15.8%. In 21 thrombocytopenic patients whose bone marrow contained normal to increased numbers of megakaryocytes, the percentage of fluorescently labeled platelets was significantly elevated (P less than .0001) to 26.9 +/- 10.9% (range, 13.3% to 57.1%). In contrast, the proportion of positively stained platelets in 23 patients with thrombocytopenia due to impaired platelet production (various conditions with reduced marrow megakaryocytes) did not significantly differ from the controls, whereas the absolute counts of TO-positive platelets were significantly lowered (P less than .0001). Differences in the distributions of the percentage values as well as of the absolute counts for TO-positive platelets between the two patient groups were again highly significant (P less than .0001). Both the sensitivity and the specificity of this method in distinguishing between these categories of thrombocytopenia were greater than or equal to 95%. We conclude that flow cytometric analysis of platelets after staining with TO is a sensitive and specific test that rapidly provides information on the thrombopoietic activity in thrombocytopenic disorders. Our data further suggest that increased amounts of residual RNA characterize platelets released under conditions of “stress thrombopoiesis.”


1997 ◽  
Vol 211 (2) ◽  
pp. 84-86 ◽  
Author(s):  
Avni Murat Avunduk ◽  
Kubilay Çetinkaya ◽  
Zerrin Kapicioglu

Bioanalysis ◽  
2020 ◽  
Author(s):  
Cynthia Mongongu ◽  
Elisabeth Madi Moussa ◽  
Florian Semence ◽  
Ingrid Roulland ◽  
Magnus Ericsson ◽  
...  

Background: IGF-I is used as a biomarker to detect Growth Hormone doping in athletes’ blood samples. Objective: Our aim was to develop and validate a fast, high-throughput and accurate quantification of intact IGF-I from volumetric absorptive microsampling (VAMS) dried blood using LC coupled to high resolution mass spectrometry (LC–HRMS). Methodology & results: IGF-I was extracted from the VAMS, released from its binding proteins, concentrated using microelution SPE and analyzed by LC–HRMS. The method was successfully validated in accordance with the World Anti-Doping Agency's requirements. Subsequently, IGF-I measurements from capillary dried blood and serum were compared. Conclusion: The combination of VAMS, microelution SPE and LC–HRMS is a promising strategy applicable to IGF-I quantification in athletes’ samples.


2003 ◽  
Vol 30 (1) ◽  
pp. 8-13 ◽  
Author(s):  
B. Greve ◽  
U. Cassens ◽  
C. Westerberg ◽  
W. Göhde jun. ◽  
W. Sibrowski ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document