Analysis of Patient-Specific Carotid Bifurcation Models Using Computational Fluid Dynamics

2011 ◽  
Vol 1 (2) ◽  
pp. 116-125 ◽  
Author(s):  
Jiyuan Tu ◽  
Kelvin K. L. Wong ◽  
Sherman C. P. Cheung ◽  
Richard Beare ◽  
Thanh Phan
2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Ian C. Campbell ◽  
Jared Ries ◽  
Saurabh S. Dhawan ◽  
Arshed A. Quyyumi ◽  
W. Robert Taylor ◽  
...  

Patient-specific computational fluid dynamics (CFD) is a powerful tool for researching the role of blood flow in disease processes. Modern clinical imaging technology such as MRI and CT can provide high resolution information about vessel geometry, but in many situations, patient-specific inlet velocity information is not available. In these situations, a simplified velocity profile must be selected. We studied how idealized inlet velocity profiles (blunt, parabolic, and Womersley flow) affect patient-specific CFD results when compared to simulations employing a “reference standard” of the patient’s own measured velocity profile in the carotid bifurcation. To place the magnitude of these effects in context, we also investigated the effect of geometry and the use of subject-specific flow waveform on the CFD results. We quantified these differences by examining the pointwise percent error of the mean wall shear stress (WSS) and the oscillatory shear index (OSI) and by computing the intra-class correlation coefficient (ICC) between axial profiles of the mean WSS and OSI in the internal carotid artery bulb. The parabolic inlet velocity profile produced the most similar mean WSS and OSI to simulations employing the real patient-specific inlet velocity profile. However, anatomic variation in vessel geometry and the use of a nonpatient-specific flow waveform both affected the WSS and OSI results more than did the choice of inlet velocity profile. Although careful selection of boundary conditions is essential for all CFD analysis, accurate patient-specific geometry reconstruction and measurement of vessel flow rate waveform are more important than the choice of velocity profile. A parabolic velocity profile provided results most similar to the patient-specific velocity profile.


Author(s):  
Jared Ries ◽  
Ian C. Campbell ◽  
Saurabh S. Dhawan ◽  
Arshed A. Quyyumi ◽  
W. Robert Taylor ◽  
...  

Computational fluid dynamics (CFD) is emerging as a powerful tool for researching the role of blood flow in disease processes. Modern clinical imaging technology such as magnetic resonance (MR) angiography and computed tomography (CT) can provide very high resolution information about the geometry of patients’ vasculature for such modeling. However, in many situations, patient-specific inlet velocity information is not available. In these situations, a simplified velocity profile must be selected. In this study, we sought to identify how idealized inlet velocity profiles (blunt flow, parabolic flow, and Womersley flow) affect patient-specific CFD results when compared to simulations employing the real measured velocity profile for each patient. Focusing on the carotid bifurcation, a site prone to atherosclerosis because of its branching geometry and oscillatory flow patterns, we investigated the effect of inlet flow assumptions on hemodynamic parameters known to be associated with atherosclerosis and vascular disease, namely mean wall shear stress (WSS) and oscillatory shear index (OSI) [1].


2021 ◽  
Vol 11 (4) ◽  
pp. 520
Author(s):  
Emily R. Nordahl ◽  
Susheil Uthamaraj ◽  
Kendall D. Dennis ◽  
Alena Sejkorová ◽  
Aleš Hejčl ◽  
...  

Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.


2021 ◽  
Vol 10 (7) ◽  
pp. 1348
Author(s):  
Karol Wiśniewski ◽  
Bartłomiej Tomasik ◽  
Zbigniew Tyfa ◽  
Piotr Reorowicz ◽  
Ernest Bobeff ◽  
...  

Background: The objective of our project was to identify a late recanalization predictor in ruptured intracranial aneurysms treated with coil embolization. This goal was achieved by means of a statistical analysis followed by a computational fluid dynamics (CFD) with porous media modelling approach. Porous media CFD simulated the hemodynamics within the aneurysmal dome after coiling. Methods: Firstly, a retrospective single center analysis of 66 aneurysmal subarachnoid hemorrhage patients was conducted. The authors assessed morphometric parameters, packing density, first coil volume packing density (1st VPD) and recanalization rate on digital subtraction angiograms (DSA). The effectiveness of initial endovascular treatment was visually determined using the modified Raymond–Roy classification directly after the embolization and in a 6- and 12-month follow-up DSA. In the next step, a comparison between porous media CFD analyses and our statistical results was performed. A geometry used during numerical simulations based on a patient-specific anatomy, where the aneurysm dome was modelled as a separate, porous domain. To evaluate hemodynamic changes, CFD was utilized for a control case (without any porosity) and for a wide range of porosities that resembled 1–30% of VPD. Numerical analyses were performed in Ansys CFX solver. Results: A multivariate analysis showed that 1st VPD affected the late recanalization rate (p < 0.001). Its value was significantly greater in all patients without recanalization (p < 0.001). Receiver operating characteristic curves governed by the univariate analysis showed that the model for late recanalization prediction based on 1st VPD (AUC 0.94 (95%CI: 0.86–1.00) is the most important predictor of late recanalization (p < 0.001). A cut-off point of 10.56% (sensitivity—0.722; specificity—0.979) was confirmed as optimal in a computational fluid dynamics analysis. The CFD results indicate that pressure at the aneurysm wall and residual flow volume (blood volume with mean fluid velocity > 0.01 m/s) within the aneurysmal dome tended to asymptotically decrease when VPD exceeded 10%. Conclusions: High 1st VPD decreases the late recanalization rate in ruptured intracranial aneurysms treated with coil embolization (according to our statistical results > 10.56%). We present an easy intraoperatively calculable predictor which has the potential to be used in clinical practice as a tip to improve clinical outcomes.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
David R. Rutkowski ◽  
Alejandro Roldán-Alzate ◽  
Kevin M. Johnson

AbstractBlood flow metrics obtained with four-dimensional (4D) flow phase contrast (PC) magnetic resonance imaging (MRI) can be of great value in clinical and experimental cerebrovascular analysis. However, limitations in both quantitative and qualitative analyses can result from errors inherent to PC MRI. One method that excels in creating low-error, physics-based, velocity fields is computational fluid dynamics (CFD). Augmentation of cerebral 4D flow MRI data with CFD-informed neural networks may provide a method to produce highly accurate physiological flow fields. In this preliminary study, the potential utility of such a method was demonstrated by using high resolution patient-specific CFD data to train a convolutional neural network, and then using the trained network to enhance MRI-derived velocity fields in cerebral blood vessel data sets. Through testing on simulated images, phantom data, and cerebrovascular 4D flow data from 20 patients, the trained network successfully de-noised flow images, decreased velocity error, and enhanced near-vessel-wall velocity quantification and visualization. Such image enhancement can improve experimental and clinical qualitative and quantitative cerebrovascular PC MRI analysis.


Stroke ◽  
2013 ◽  
Vol 44 (suppl_1) ◽  
Author(s):  
Yoshifumi Hayashi ◽  
Takanobu Yagi ◽  
Yasutaka Tobe ◽  
Yuki Iwabuchi ◽  
Momoko Yamanashi ◽  
...  

[Background and purpose] During a clipping surgery, an unruptured intracerebral aneurysm often presented a spatially-localized red-colored "wall-thinning" area. The wall thinning was believed to be related with the risk of rupture. The present aim is given to investigate the predictability of a wall thinning area using computational fluid dynamics (CFD). [Method] We chose 16 unruptured aneurysms (12 MCA, 4 ICA) with clipping surgery and 24 wall-thinning areas were detected from the operation video. CFD study was carried out using patient-specific angiographic data. The wall shear stress (WSS) and the wall pressure were evaluated. [Results] The WSS magnitude was found to be uncorrelated with wall thinning. On the other hand, 20 wall-thinning areas (83%) exhibited a presence of “flow impingement”, which was defined to give the spatial variation of the WSS vector to be divergent with the local elevation of the wall pressure. From CFD, 27 flow impingements were detected and classified according to the degree of divergence. Seven impingements are full-divergent and all of them (100%) are located in the wall thinning areas. The remaining 20 impingements were partial-divergent and 13 impingements of them (65%) were located in the wall thinning areas. A classification of full-/partial-divergent flow impingement was statistically significant for the prediction of wall-thinning areas (P<0.01). [Conclusions] The full-divergent flow impingement was found to be a reliable predictor of the wall thinning area in unruptured intracerebral aneurysms. The present results demonstrated the malignant nature of flow impingement for promoting the thinning of aneurysmal walls.


Sign in / Sign up

Export Citation Format

Share Document