scholarly journals Remote Sensing of Atmospheric Water Vapor Using the Moderate Resolution Imaging Spectroradiometer

2005 ◽  
Vol 22 (3) ◽  
pp. 309-314 ◽  
Author(s):  
P. Albert ◽  
R. Bennartz ◽  
R. Preusker ◽  
R. Leinweber ◽  
J. Fischer

Abstract This paper presents first validation results for an algorithm developed for the retrieval of integrated columnar water vapor from measurements of the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on board the polar-orbiting Terra and Aqua platforms. The algorithm is based on the absorption of reflected solar radiation by atmospheric water vapor and allows the retrieval of integrated water vapor above cloud-free land surfaces. A comparison of the retrieved water vapor with measurements of the Microwave Water Radiometer at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site for a 10-month period in 2002 showed an rms deviation of 1.7 kg m−2 and a bias of 0.6 kg m−2. A comparison with radio soundings in central Europe from July 2002 to April 2003 showed an rms deviation of 2 kg m−2 and a bias of −0.8 kg m−2.

2021 ◽  
Vol 14 (4) ◽  
pp. 3033-3048
Author(s):  
David D. Turner ◽  
Ulrich Löhnert

Abstract. Thermodynamic profiles in the planetary boundary layer (PBL) are important observations for a range of atmospheric research and operational needs. These profiles can be retrieved from passively sensed spectral infrared (IR) or microwave (MW) radiance observations or can be more directly measured by active remote sensors such as water vapor differential absorption lidars (DIALs). This paper explores the synergy of combining ground-based IR, MW, and DIAL observations using an optimal-estimation retrieval framework, quantifying the reduction in the uncertainty in the retrieved profiles and the increase in information content as additional observations are added to IR-only and MW-only retrievals. This study uses ground-based observations collected during the Perdigão field campaign in central Portugal in 2017 and during the DIAL demonstration campaign at the Atmospheric Radiation Measurement Southern Great Plains site in 2017. The results show that the information content in both temperature and water vapor is higher for the IR instrument relative to the MW instrument (thereby resulting in smaller uncertainties) and that the combined IR + MW retrieval is very similar to the IR-only retrieval below 1.5 km. However, including the partial profile of water vapor observed by the DIAL increases the information content in the combined IR + DIAL and MW + DIAL water vapor retrievals substantially, with the exact impact vertically depending on the characteristics of the DIAL instrument itself. Furthermore, there is a slight increase in the information content in the retrieved temperature profile using the IR + DIAL relative to the IR-only; this was not observed in the MW + DIAL retrieval.


2020 ◽  
Author(s):  
David D. Turner ◽  
Ulrich Löhnert

Abstract. Thermodynamic profiles in the planetary boundary layer (PBL) are important observations for a range of atmospheric research and operational needs. These profiles can be retrieved from passively sensed spectral infrared (IR) or microwave (MW) radiance observations, or can be more directly measured by active remote sensors such as water vapor differential absorption lidars (DIALs). This paper explores the synergy of combining ground-based IR, MW, and DIAL observations using an optimal estimation retrieval framework, quantifying the reduction in the uncertainty in the retrieved profiles and the increase in information content as additional observations are added to IR-only and MW-only retrievals. This study uses ground-based observations collected during the Perdigao field campaign in central Portugal in 2017 and during the DIAL demonstration campaign at the Atmospheric Radiation Measurement Southern Great Plains site in 2017. The results show that the information content in both temperature and water vapor is higher for IR instrument relative to the MW instrument (thereby resulting in smaller uncertainties), and that the combined IR+MW retrieval is very similar to the IR-only retrieval below 1.5 km. However, including the partial profile of water vapor observed by the DIAL increases the information content in the combined IR+DIAL and MW+DIAL water vapor retrievals substantially, with the exact impact vertically depending on the characteristics of the DIAL instrument itself. Furthermore, there is slight increase in the information content in the retrieved temperature profile using the IR+DIAL relative to the IR-only; this was not observed in the MW+DIAL retrieval.


2013 ◽  
Vol 6 (11) ◽  
pp. 2989-3034 ◽  
Author(s):  
R. C. Levy ◽  
S. Mattoo ◽  
L. A. Munchak ◽  
L. A. Remer ◽  
A. M. Sayer ◽  
...  

Abstract. The twin Moderate resolution Imaging Spectroradiometer (MODIS) sensors have been flying on Terra since 2000 and Aqua since 2002, creating an extensive data set of global Earth observations. Here, we introduce the Collection 6 (C6) algorithm to retrieve aerosol optical depth (AOD) and aerosol size parameters from MODIS-observed spectral reflectance. While not a major overhaul from the previous Collection 5 (C5) version, there are enough changes that there are significant impacts to the products and their interpretation. The C6 aerosol data set will be created from three separate retrieval algorithms that operate over different surface types. These are the two "Dark Target" (DT) algorithms for retrieving (1) over ocean (dark in visible and longer wavelengths) and (2) over vegetated/dark-soiled land (dark in the visible), plus the "Deep Blue" (DB) algorithm developed originally for retrieving (3) over desert/arid land (bright in the visible). Here, we focus on DT-ocean and DT-land (#1 and #2). We have updated assumptions for central wavelengths, Rayleigh optical depths and gas (H2O, O3, CO2, etc.) absorption corrections, while relaxing the solar zenith angle limit (up to ≤ 84°) to increase poleward coverage. For DT-land, we have updated the cloud mask to allow heavy smoke retrievals, fine-tuned the assignments for aerosol type as function of season/location, corrected bugs in the Quality Assurance (QA) logic, and added diagnostic parameters such topographic altitude. For DT-ocean, improvements include a revised cloud mask for thin-cirrus detection, inclusion of wind speed dependence on the surface reflectance, updates to logic of QA Confidence flag (QAC) assignment, and additions of important diagnostic information. At the same time, we quantified how "upstream" changes to instrument calibration, land/sea masking and cloud masking will also impact the statistics of global AOD, and affect Terra and Aqua differently. For Aqua, all changes will result in reduced global AOD (by 0.02) over ocean and increased AOD (by 0.02) over land, along with changes in spatial coverage. We compared preliminary data to surface-based sun photometer data, and show that C6 should improve upon C5. C6 will include a merged DT/DB product over semi-arid land surfaces for reduced-gap coverage and better visualization, and new information about clouds in the aerosol field. Responding to the needs of the air quality community, in addition to the standard 10 km product, C6 will include a global (DT-land and DT-ocean) aerosol product at 3 km resolution.


2019 ◽  
Vol 11 (3) ◽  
pp. 257 ◽  
Author(s):  
David Frantz ◽  
Marion Stellmes ◽  
Patrick Hostert

Analysis Ready Data (ARD) have undergone the most relevant pre-processing steps to satisfy most user demands. The freely available software FORCE (Framework for Operational Radiometric Correction for Environmental monitoring) is capable of generating Landsat ARD. An essential step of generating ARD is atmospheric correction, which requires water vapor data. FORCE relies on a water vapor database obtained from the Moderate Resolution Imaging Spectroradiometer (MODIS). However, two major drawbacks arise from this strategy: (1) The database has to be compiled for each study area prior to generating ARD; and (2) MODIS and Landsat commissioning dates are not well aligned. We have therefore compiled an application-ready global water vapor database to significantly increase the operational readiness of ARD production. The free dataset comprises daily water vapor data for February 2000 to July 2018 as well as a monthly climatology that is used if no daily value is available. We systematically assessed the impact of using this climatology on surface reflectance outputs. A global random sample of Landsat 5/7/8 imagery was processed twice (i) using daily water vapor (reference) and (ii) using the climatology (estimate), followed by computing accuracy, precision, and uncertainty (APU) metrics. All APU measures were well below specification, thus the fallback usage of the climatology is generally a sound strategy. Still, the tests revealed that some considerations need to be taken into account to help quantify which sensor, band, climate, and season are most or least affected by using a fallback climatology. The highest uncertainty and bias is found for Landsat 5, with progressive improvements towards newer sensors. The bias increases from dry to humid climates, whereas uncertainty increases from dry and tropic to temperate climates. Uncertainty is smallest during seasons with low variability, and is highest when atmospheric conditions progress from a dry to a wet season (and vice versa).


2010 ◽  
Vol 49 (8) ◽  
pp. 1665-1680 ◽  
Author(s):  
Yunjun Yao ◽  
Shunlin Liang ◽  
Qiming Qin ◽  
Kaicun Wang

Abstract Monitoring land surface drought using remote sensing data is a challenge, although a few methods are available. Evapotranspiration (ET) is a valuable indicator linked to land drought status and plays an important role in surface drought detection at continental and global scales. In this study, the evaporative drought index (EDI), based on the estimated actual ET and potential ET (PET), is described to characterize the surface drought conditions. Daily actual ET at 4-km resolution for April–September 2003–05 across the continental United States is estimated using a simple improved ET model with input solar radiation acquired by Moderate-Resolution Imaging Spectroradiometer (MODIS) at a spatial resolution of 4 km and input meteorological parameters from NCEP Reanalysis-2 data at a spatial resolution of 32 km. The PET is also calculated using some of these data. The estimated actual ET has been rigorously validated with ground-measured ET at six Enhanced Facility sites in the Southern Great Plains (SGP) of the Atmosphere Radiation Measurement Program (ARM) and four AmeriFlux sites. The validation results show that the bias varies from −11.35 to 27.62 W m−2 and the correlation coefficient varies from 0.65 to 0.86. The monthly composites of EDI at 4-km resolution during April–September 2003–05 are found to be in good agreement with the Palmer Z index anomalies, but the advantage of EDI is its finer spatial resolution. The EDI described in this paper incorporates information about energy fluxes in response to soil moisture stress without requiring too many meteorological input parameters, and performs well in assessing drought at continental scales.


Sign in / Sign up

Export Citation Format

Share Document