Laboratory Simulation of Induction Tube Welding

1986 ◽  
Vol 23 (2) ◽  
pp. 159-165
Author(s):  
L. Hobson ◽  
A. Taylor ◽  
A. H. Woodcock

An advanced laboratory exercise is outlined in which the industrial technique of induction tube welding is simulated on a laboratory scale. Details are given of the different measurement techniques used. This experiment may be used to introduce basic electrical engineering topics into engineering disciplines of all types.

2018 ◽  
Vol 64 ◽  
pp. 131-148
Author(s):  
J. Brian Davies

Alex Cullen combined the sharpest of scientific minds with a gentle personality and a great sense of humour. He was Professor and Head of the Department of Electrical Engineering at Sheffield from 1955 to 1967, and then Head of the Department of Electrical Engineering at University College London (UCL) until 1980. He continued his research there as a Science and Engineering Research Council Senior Fellow until 1985, and for some years as Research Fellow of UCL. His research concerned electromagnetic waves over a wide range of microwave devices and measurement techniques, the latter at a fundamental level. These contributions were of a highly innovative and ‘ground-breaking’ nature. He was appointed OBE in 1960, and elected Fellow of the Royal Society in 1977. He was an accomplished jazz musician, playing drums and clarinet. He was a signatory of a letter to The Times in January 1986, calling on Prime Minister Margaret Thatcher to ‘Save British Science’. This led to the foundation of the Save British Science pressure group, now the Campaign for Science and Engineering (CaSE), which has built up an enviable reputation with politicians and the media in representing the concerns of scientists and engineers. When (now Sir) Eric Ash left UCL in 1985 to become Rector of Imperial College, he remarked that Alex was ‘the last gentleman in the business’.


Author(s):  
Thomas Von Langenthal ◽  
Nikolaos Zarzalis ◽  
Alexandra Loukou

Abstract The characterization of the two-phase kerosene/air flow near the nozzle of an aero engine combustor is important in order to understand the combustion characteristics of the burner. Typically, Particle Image Velocimetry (PIV) or Laser Doppler Velocimetry (LDV) is used to measure velocities inside aero engine combustors. However, these measurement techniques rely on tracer particles to visualize the flow field and are usually only able to measure the velocity field of one phase at a time. In the case of PIV measurements both the flow tracers and the kerosene droplets scatter the laser light and thus, appear on the PIV recordings. Depending on droplet size and flow velocity, these kerosene droplets do not necessarily follow the airflow leading to errors in the derived velocity field. This work presents a method on how to separate kerosene droplets from flow tracers depending on their optical characteristics in the PIV recording. This phase separation enables the independent measurement of the flow fields of both the gaseous and liquid phase at the same time as well as the instantaneous slip velocity between droplets and gaseous flow using a standard PIV setup. The method is demonstrated on a laboratory scale aero engine combustor operated at atmospheric conditions. The obtained results show, that in the setup under investigation, gaseous and liquid phase can have significantly different flow fields with kerosene droplets moving in the opposite direction of the recirculating airflow.


1962 ◽  
Vol 14 ◽  
pp. 441-444 ◽  
Author(s):  
J. E. Geake ◽  
H. Lipson ◽  
M. D. Lumb

Work has recently begun in the Physics Department of the Manchester College of Science and Technology on an attempt to simulate lunar luminescence in the laboratory. This programme is running parallel with that of our colleagues in the Manchester University Astronomy Department, who are making observations of the luminescent spectrum of the Moon itself. Our instruments are as yet only partly completed, but we will describe briefly what they are to consist of, in the hope that we may benefit from the comments of others in the same field, and arrange to co-ordinate our work with theirs.


1975 ◽  
Vol 26 ◽  
pp. 87-92
Author(s):  
P. L. Bender

AbstractFive important geodynamical quantities which are closely linked are: 1) motions of points on the Earth’s surface; 2)polar motion; 3) changes in UT1-UTC; 4) nutation; and 5) motion of the geocenter. For each of these we expect to achieve measurements in the near future which have an accuracy of 1 to 3 cm or 0.3 to 1 milliarcsec.From a metrological point of view, one can say simply: “Measure each quantity against whichever coordinate system you can make the most accurate measurements with respect to”. I believe that this statement should serve as a guiding principle for the recommendations of the colloquium. However, it also is important that the coordinate systems help to provide a clear separation between the different phenomena of interest, and correspond closely to the conceptual definitions in terms of which geophysicists think about the phenomena.In any discussion of angular motion in space, both a “body-fixed” system and a “space-fixed” system are used. Some relevant types of coordinate systems, reference directions, or reference points which have been considered are: 1) celestial systems based on optical star catalogs, distant galaxies, radio source catalogs, or the Moon and inner planets; 2) the Earth’s axis of rotation, which defines a line through the Earth as well as a celestial reference direction; 3) the geocenter; and 4) “quasi-Earth-fixed” coordinate systems.When a geophysicists discusses UT1 and polar motion, he usually is thinking of the angular motion of the main part of the mantle with respect to an inertial frame and to the direction of the spin axis. Since the velocities of relative motion in most of the mantle are expectd to be extremely small, even if “substantial” deep convection is occurring, the conceptual “quasi-Earth-fixed” reference frame seems well defined. Methods for realizing a close approximation to this frame fortunately exist. Hopefully, this colloquium will recommend procedures for establishing and maintaining such a system for use in geodynamics. Motion of points on the Earth’s surface and of the geocenter can be measured against such a system with the full accuracy of the new techniques.The situation with respect to celestial reference frames is different. The various measurement techniques give changes in the orientation of the Earth, relative to different systems, so that we would like to know the relative motions of the systems in order to compare the results. However, there does not appear to be a need for defining any new system. Subjective figures of merit for the various system dependon both the accuracy with which measurements can be made against them and the degree to which they can be related to inertial systems.The main coordinate system requirement related to the 5 geodynamic quantities discussed in this talk is thus for the establishment and maintenance of a “quasi-Earth-fixed” coordinate system which closely approximates the motion of the main part of the mantle. Changes in the orientation of this system with respect to the various celestial systems can be determined by both the new and the conventional techniques, provided that some knowledge of changes in the local vertical is available. Changes in the axis of rotation and in the geocenter with respect to this system also can be obtained, as well as measurements of nutation.


Author(s):  
T. Schober

Nb, Ta and V are prototype substances for the study of the endothermic reactions of H with metals. Such metal-hydrogen reactions have gained increased importance due to the application of metal-hydrides in hydrogen- und heat storage devices. Electron microscopy and diffraction were demonstrated to be excellent methods in the study of hydride morphologies and structures (1). - Figures 1 and 2 show the NbH and TaH phase diagrams (2,3,4). EM techniques have contributed substantially to the elucidation of the structures and domain configurations of phases β, ζ and ε (1,4). Precision length measurement techniques of distances in reciprocal space (5) recently led to a detailed understanding of the distortions of the unit cells of phases ζ and ε (4). In the same work (4) the existence of the new phase η was shown. It is stable near -68 °C. The sequence of transitions is thus below 70 %.


1999 ◽  
Vol 4 (1) ◽  
pp. 6-7
Author(s):  
James J. Mangraviti

Abstract The accurate measurement of hip motion is critical when one rates impairments of this joint, makes an initial diagnosis, assesses progression over time, and evaluates treatment outcome. The hip permits all motions typical of a ball-and-socket joint. The hip sacrifices some motion but gains stability and strength. Figures 52 to 54 in AMA Guides to the Evaluation of Permanent Impairment (AMA Guides), Fourth Edition, illustrate techniques for measuring hip flexion, loss of extension, abduction, adduction, and external and internal rotation. Figure 53 in the AMA Guides, Fourth Edition, illustrates neutral, abducted, and adducted positions of the hip and proper alignment of the goniometer arms, and Figure 52 illustrates use of a goniometer to measure flexion of the right hip. In terms of impairment rating, hip extension (at least any beyond neutral) is irrelevant, and the AMA Guides contains no figures describing its measurement. Figure 54, Measuring Internal and External Hip Rotation, demonstrates proper positioning and measurement techniques for rotary movements of this joint. The difference between measured and actual hip rotation probably is minimal and is irrelevant for impairment rating. The normal internal rotation varies from 30° to 40°, and the external rotation ranges from 40° to 60°.


Sign in / Sign up

Export Citation Format

Share Document