Failed inferior vena cava filter retrieval by conventional method: Analysis of its causes and retrieval of it by modified double-loop technique

2014 ◽  
Vol 30 (8) ◽  
pp. 549-556 ◽  
Author(s):  
Eun Cho ◽  
Kyung Jae Lim ◽  
Jeong Hyun Jo ◽  
Gyoo-Sik Jung ◽  
Byeong Ho Park

Objectives To evaluate the complications of the temporary implanted inferior vena cava (IVC) filter and the feasibility of double-loop technique for removal of complicated IVC filters. Methods From January 2012 to December 2013, a total of 25 patients with IVC filter were referred for IVC filter retrieval. There were 20 Celect®, 3 OptEase®, and 2 Günther-Tulip® filters. All of the patients were evaluated with a pre-procedural CT scan to identify any complications. The IVC filters which had failed to be retrieved by the conventional method were evaluated, and retrieval was attempted with double loop technique. Results Sixteen of 25 (64%) filters had complications; IVC wall penetration ( n = 11, 44%), tilted within IVC ( n = 6, 24%), embedded struts ( n = 3, 12%), and fracture of the strut ( n = 1, 4%). The complications were overlapped in five patients. Two of them (8%) had also complained of filter-related pain. The success rate of IVC filter retrieval by double-loop technique was 14/16 (87.5%). There was no major filter retrieval-related complications. Conclusions The double-loop technique is a safe and feasible method for complicated IVC filter retrieval.

2017 ◽  
Vol 22 (6) ◽  
pp. 512-517 ◽  
Author(s):  
Jieun Kang ◽  
Heung-Kyu Ko ◽  
Ji Hoon Shin ◽  
Gi-Young Ko ◽  
Kyung-Wook Jo ◽  
...  

Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4690-4690
Author(s):  
Filip Ionescu ◽  
Nwabundo Anusim ◽  
Eva Ma ◽  
Lihua Qu ◽  
Leann Blankenship ◽  
...  

Background: Inferior vena cava (IVC) filters are indicated in patients with deep vein thrombosis (DVT) or pulmonary embolism (PE) who either have contraindications to or have failed anticoagulation (AC). Given rising concerns about their safety and efficacy, the FDA has issued a communication urging clinicians to remove filters (optimally, within 90 days post-implantation). According to national data retrieval rates remain low. Our study aimed to assess IVC filter retrieval rates and factors that influence retrieval. Methods: This is a single center, retrospective cohort study of patients who had IVC filter placement between December 2015 and December 2018. Subjects were identified using procedural codes for IVC filter insertion; data regarding demographics, comorbidities, retrieval, IVC filter-related complications and subsequent thromboembolic events were obtained by direct chart review. Survival analyses and a Cox regression model were performed using JMP statistical software. Results: Over 3 years, 494 patients with IVC filters were identified; 305 (62%) were retrievable. The average age at placement was 69±16 years; 249 (50%) were men and 332 (67%) were Caucasian. After excluding patients who died or were lost to follow-up within 30 days of placement or were discharged to hospice from the index admission, 258 patients with retrievable filters remained (54 retrieved). Indications for IVC filter placement were PE ± DVT 90 (35%), proximal DVT 159 (62%) and prophylactic 9 (3%). Forty two percent of patients (109) were restarted on AC at discharge, while an additional 18% (total 155) received AC at some point thereafter. The rate of retrieval was 8% at 90 days, 23% at 1 year and 28% at 2 years (Figure A). The proportional hazards model identified resumption of AC at any time (HR 3.11, 95%CI 1.6-6.8, p=0.0006) as the strongest predictor of retrieval; AC at discharge was not predictive. Advanced age at placement (HR 0.97 per unit change, 0.96-0.99, p=0.004) and active malignancy (HR 0.5, 95%CI 0.24-0.98, p=0.04) were associated with a lower likelihood of retrieval. The initial thrombotic event, the reversibility of the contraindication to AC, the placing service, sex, ethnicity and other comorbid conditions did not have an impact on retrieval. Kaplan-Meier analysis revealed that subjects who ever resumed AC had significantly higher rates of retrieval at 90 days (11% vs 3.4%) and at 1 year (33% vs 9.7%, log-rank p=0.0003, Figure B) when compared to those who did not. Only four patients experienced IVC filter-related complications (2 filter thrombosis, 1 IVC penetration, 1 device tilting); all occurred 2 or more years after placement. Recurrent thromboembolic events occurred in 50 patients (5 PE, 48 proximal DVT) with no significant difference in frequency between subjects with retrieved and non-retrieved filters; one PE and one DVT occurred at 1 month and 1 week respectively after retrieval. Conclusion: Despite efforts to increase awareness of IVC filter-associated complications, the unweighted retrieval rate remained below the nationally reported average of 30%. Persistent risk factors for thrombosis such as active malignancy or increasing age and poor prognosis may play a role in the decision to defer retrieval. In our study, resumption of AC proved a powerful predictor of retrieval, with rates approaching expected values in this population. Active surveillance for resolution of contraindications to AC post-IVC filter placement is crucial in increasing retrieval rates. Figure Disclosures No relevant conflicts of interest to declare.


2016 ◽  
Vol 22 (1) ◽  
pp. 51-56 ◽  
Author(s):  
John P Winters ◽  
Christopher S Morris ◽  
Chris E Holmes ◽  
Patricia Lewis ◽  
Anant D Bhave ◽  
...  

Published reports indicate low retrieval rates for retrievable inferior vena cava (IVC) filters. We performed a historic-controlled study of a 5-year intervention (March 2007 to February 2012) to improve IVC filter retrieval rates at a university medical center serving a rural area. All adults with a retrievable filter placed were included, except those with a life expectancy <6 months. The intervention included initial verbal counseling and printed educational materials, correspondence after discharge, and a hematology consultation. The control group included patients with retrievable filters placed in the 15 months preceding study initiation. In the control group, 116 filters were placed and 27 (23%) were removed, compared to 378 filters placed and 169 (45%) removed during the intervention. Adjusting for patient characteristics, the odds ratio of retrieval during the intervention was 3.03 (95% CI 1.85–4.27) compared to the control period. An intervention including patient education and hematology follow-up appeared to significantly improve IVC filter retrieval rates.


2021 ◽  
pp. 153857442110225
Author(s):  
Haidong Wang ◽  
Zhenhua Liu ◽  
Xiaofei Zhu ◽  
Jianlong Liu ◽  
Libo Man

Background: Inferior vena cava (IVC) filters are commonly used in China to prevent pulmonary embolisms in patients with deep vein thrombosis. However, IVC filter removal is complicated when the filter has penetrated the IVC wall and endovascular techniques usually fail. The purpose of this study was to evaluate the effectiveness and safety of retroperitoneal laparoscopic-assisted retrieval of wall-penetrating IVC filters after endovascular techniques have failed. Patients and Methods: We retrospectively evaluated a series of 8 patients who underwent retroperitoneal laparoscopic-assisted retrieval of a wall-penetrating IVC filter between December 2017 and November 2019. All patients had experienced at least 1 failure with endovascular retrieval before the study. The filters were slanted and the proximal retrieval hooks penetrated the posterior lateral IVC wall in all patients on computed tomography. Demographic information, operation parameters, and complications were recorded and analyzed. All patients were followed up for at least 12 months. Results: The procedure was successful in all patients. The median surgery time was 53.6 ± 12.7 min and the average blood loss was 45.0 ± 13.5 ml. No serious complication occurred during the patients’ hospitalization, which was an average of 6.4 days. The median follow-up time was 15.1 months, and no patient had deep vein thrombosis recurrence. Conclusions: Retroperitoneal laparoscopic-assisted retrieval is a feasible and effective technique, particularly when proximal retrieval hooks penetrate the posterior lateral wall of the IVC after endovascular techniques have failed. To some extent, the development of this technique at our institution has increased the success rate of filter removal and improved patient satisfaction.


2022 ◽  
Author(s):  
Mark Sheehan ◽  
Kristopher Coppin ◽  
Cormac O’ Brien ◽  
Andrew McGrath ◽  
Mark Given ◽  
...  

Abstract Background:To evaluate Inferior vena cava (IVC) filter retrieval practices over a 9-year period at an academic hospital with a prospectively maintained IVC filter registry. Method:An IVC filter registry was maintained prospectively within our institution. We reviewed cases between August 2011 and June 2020, following filter status, retrieval plans, and eventual retrieval date. The validity of the database was cross referenced with a Picture Archiving and Communication System and patient records. Results:343 patients had IVC filters inserted. Three filter types were used, Celect (Cook Medical) in 189, Gunther Tulip (GT) (Cook Medical) in 65, ALN (ALN) in 89. 196 filters were retrieved, 108 were made permanent, 36 died before retrieval, and 3 were yet to be retrieved. Retrieval rates were 92.5% overall (86% for GT, 93% for Celect and 94.5% for ALN). The mean dwell time for successful retrieval was 59 days with the majority of insertions (85%) removed in under 100 days. Failed initial retrieval occurred in 23 patients, 10 (43%) were retrieved at second attempt, 13/23 filters remained in-situ and were deemed permanent after discussion with the patient and referring team. Conclusion:The removal of IVC filters, when indication for insertion has past, is no longer the sole responsibility of the referring physician but also the responsibility of the Interventionalist. Our retrieval rates of 92.5% of eligible IVC filters highlights the value of maintaining a prospective IVC filter registry.


Blood ◽  
2005 ◽  
Vol 106 (11) ◽  
pp. 914-914
Author(s):  
Nikhil Bhalla ◽  
Anca Bulgaru ◽  
Lynn Church ◽  
Dinesh Kapur ◽  
Herb Lustberg ◽  
...  

Abstract Inferior vena cava (IVC) filters are used in patients (pts.) with Deep Venous Thrombosis (DVT) to prevent pulmonary embolism (PE) when anticoagulation cannot be administered. The purpose of this study was to analyze the use and outcomes of IVC filters in a community hospital. We reviewed the medical records of all pts. who had IVC filters implanted at William W. Backus Hospital between May 2003 and May 2005. Follow up information was obtained up to August 2005 by mailings from the attending physicians. 125 IVC filters were implanted in 121 pts., ages 18 to 93, with 61 males and 60 females. The indications for implantation were contraindication as follows: to anticoagulation in 72 pts. (58%), up coming surgical procedures in 33 pts. (26%), and severity of clot burden in 20 pts. (16%). 123 (98%) filters were deployed into an infrarenal position and 2 into a suprarenal position due to extensive clot in the IVC. Of the 105 filters that were not retrieved 60 were Gunther Tulip (GT) retrievable IVC filters, 42 were Cordis Trapease (CT) permanent IVC filters, 2 were stainless steel Greenfield IVC filters, and 1 was a Cordis Optease (CO) IVC filter. Of the 20 retrieved filters 19 were GT retrievable IVC filters and 1 was a CO IVC filter. Of the 125 filters, 74 were intended to be permanent filters (59%) and 51 (41%) were inserted with intention of retrieval. 31/51 (60%) were eventually not retrieved because of various reasons: need for additional surgery (12), poor pulmonary reserve (5), high-risk of bleeding (5), severity of clot burden (4), short life expectancy (4), and extremely high risk of recurrent DVT (1). Short-term and long-term anticoagulation was used in conjunction with the IVC filters in 21 and 81 pts. respectively. 38 (31%) of the 121 pts. experienced recurrent venous thromboembolism (VTE), 37 developed symptomatic DVT and 1 had a symptomatic PE. 3/20 (15%) of the pts. who had their filters retrieved developed recurrent DVT (18, 22, and 76 days after filter retrieval) compared with 34/105 (32%) pts. who had permanent filters. The only objectively documented symptomatic PE occurred in a pt. with a permanent filter. This pt. had a recurrent PE 7 months post GT IVC filter insertion diagnosed by chest CT scan with PE protocol. Complications were as follows: 1 pt. had transient hypertension immediately after IVC insertion and 1 pt. developed a transient low-grade fever after retrieval. 1 pt. developed retroperitoneal hematoma upon retrieval 75 days after implantation as documented by an IVC Gram and this pt. recovered without need for any intervention and there were no adverse clinical consequences. The implantation periods ranged from 2 to 104 days in the 20 retrieved filters with mean/median of 20/9 days. 4 of the 20 retrieved filters (20%) contained trapped emboli and none of these pts. subsequently developed PE. The GT retrievable IVC filter is now the filter of choice at our institution and can be implanted permanently or with retrieval in mind. Conclusion: Retrievable filters were removed up to 104 days post insertion in this series of pts. and the incidence of complications was negligible. Retrievable IVC filters may be substituted for permanent IVC filters to preserve the option of retrieval, and retrieval of filters beyond 3 months post implantation is feasible and should be studied further.


Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 2553-2553
Author(s):  
Amanjit S. Baadh ◽  
Stephen Rivoli ◽  
Jack Ansell ◽  
Robert E. Graham

Abstract Abstract 2553 Background: Inferior Vena Cava (IVC) filter placement has increased significantly over the past few decades, due to expanding indications for filter placement. Indications for filter placement vary widely depending on which professional society recommendations are followed. Our objectives were to record the number of IVC filters placed in our medium sized metropolitan teaching hospital, assess the effect of medical specialty on placement and evaluate compliance with accepted standards as set by the American College of Chest Physicians (ACCP) and the Society of Interventional Radiology (SIR). Methods: Single-center, retrospective medical record review of all patients who received an IVC filter over 26 months (01/30/2008 - 4/5/2010). Inclusion criteria included patients from both sexes, all ages, filter placement within the aforementioned dates and inpatient procedures performed by interventional radiology. A total of 443 IVC filters were placed in our institution over the time period studied. 48.1% (213) of these filters were placed by interventional radiology. Of these, 187 were reviewed with 26 excluded do to incomplete patient records available at the time of review (July 2010). Medical records were reviewed for patient demographics, clinical course, and compliance with accepted guidelines set by the ACCP and SIR. Results: The average age was 75.3 years and 43.9% of the patients were males. 76.2% of patients were on the medical service (internal medicine and its subspecialties) whereas 22.8% were on non medical services. 87.2 % of filters were recommended by medicine and its subspecialties and 12.8% by non medical specialties. 43.3% of filters placed met guidelines established by the ACCP (Table 1). 79.1% of filters placed met SIR guidelines (Table 2). No documentation was available to assess compliance for 20.9% of filters. 46% of filters placed by internal medicine and its subspecialties met ACCP criteria whereas only 25% of filters recommended by non medicine specialties were compliant with criteria (p value=0.039, 95% CI). Physicians within internal medicine and its subspecialties were compliant with SIR guidelines for 84% of the filters placed, whereas only 46% of non medicine physicians met these indications (p=0.001, 95% CI). 35.8% of filters placed met SIR criteria but did not meet ACCP guidelines. Conclusions: Indications for IVC filter placement varied significantly in this study, less than half of filters placed met ACCP guidelines, yet over three-fourths met criteria set by the SIR, especially when comparing medicine and non medicine specialties. In analyzing the filters which meet indications set by SIR but not ACCP it becomes apparent that most of these are placed for patients classified as “fall risks”, failures of anticoagulation, limited cardiopulmonary reserve and medication noncompliance. Further research needs to be guided towards evaluating if these indications truly merit the placement of an IVC filter. This study strongly suggests a need for harmonization of current guidelines espoused by professional societies. A limitation of our study was that 230 filters placed by vascular surgery and interventional cardiology were not reviewed. Disclosures: No relevant conflicts of interest to declare.


Blood ◽  
2016 ◽  
Vol 128 (22) ◽  
pp. 5912-5912
Author(s):  
Rena Shah ◽  
Anita Turk ◽  
Bilal Rahim ◽  
Waddah Arafat ◽  
Moniba Nazeef ◽  
...  

Abstract Inferior vena cava (IVC) filters, first introduced in 1998, have been utilized to reduce risk of pulmonary embolism (PE) in the setting of an inability to anticoagulate patients. The use of IVC filters has increased and continues to rise, especially with the introduction of retrievable IVC filters. Since their initial introduction, guidelines have been developed on the appropriate use of IVC filters. According to the American College of Chest Physicians (ACCP), the use of an IVC filter is limited to patients with an absolute contraindication to therapeutic anticoagulation or failure or complication of anticoagulation in the setting an acute proximal venous thrombus. Relative indications for IVC filter placement include high clot burden in setting of low cardiopulmonary reserve, high risk patients, or severe trauma without documented thrombosis. In 2010, the FDA announced a safety communication recommending removal of retrievable IVC filters due to reports of several adverse clinical outcomes associated with retained filters including thrombus formation, recurrent PE, filter migration, erosion or perforation through the IVC wall, and filter fracture with fragment embolization. In 2014, the FDA recommended removal of the IVC filter within 2 months after filter placement if the patient's risk of thrombosis had passed. In this retrospective analysis of IVC filter management, we reviewed indications for placement according to current guidelines as set by the ACCP, initiation of appropriate anticoagulation, complication rates, and retrieval rates. In addition, we compared the data prior to the FDA recommendations in late 2014 and data after the recommendations to determine if there was a change in practice. After reviewing 179 patients, 89 patients in 2014 and 90 patients in 2015, who underwent IVC filter placement, only 81% (N=145) of patients had appropriate indications for IVC filter placement and 30% (N=54) of patients had inappropriate anticoagulation after IVC filter placement, given as prophylactic dosing of low molecular weight heparin. A comparison of retrieval rates prior to and after the FDA warning, showed a 19% (60% in 2014 vs 79% in 2015) improvement in IVC filter removals. There was an 11% complication rate, mainly related to IVC filter related acute DVT or IVC occlusion. A root cause analysis specifically for inappropriate IVC filter placement and appropriate anticoagulation and determined that familiarity of the guidelines and non-evidence based recommendations from consultants were major factors. Based on the analysis, we next plan to utilize the electronic health record system to help clinicians understand indications and when to initiate appropriate anticoagulation, with the opportunity for hematology consultants to be involved in situations that do not clearly fit within published guidelines. Disclosures No relevant conflicts of interest to declare.


2013 ◽  
Vol 68 ◽  
pp. S10
Author(s):  
Zafar Hashim ◽  
John Asquith ◽  
Mark Cowling ◽  
Christopher Day ◽  
David Wells

Sign in / Sign up

Export Citation Format

Share Document