Inferior vena cava (IVC) filter retrieval rates at the University Hospital of North Staffordshire

2013 ◽  
Vol 68 ◽  
pp. S10
Author(s):  
Zafar Hashim ◽  
John Asquith ◽  
Mark Cowling ◽  
Christopher Day ◽  
David Wells
2017 ◽  
Vol 22 (6) ◽  
pp. 512-517 ◽  
Author(s):  
Jieun Kang ◽  
Heung-Kyu Ko ◽  
Ji Hoon Shin ◽  
Gi-Young Ko ◽  
Kyung-Wook Jo ◽  
...  

Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4690-4690
Author(s):  
Filip Ionescu ◽  
Nwabundo Anusim ◽  
Eva Ma ◽  
Lihua Qu ◽  
Leann Blankenship ◽  
...  

Background: Inferior vena cava (IVC) filters are indicated in patients with deep vein thrombosis (DVT) or pulmonary embolism (PE) who either have contraindications to or have failed anticoagulation (AC). Given rising concerns about their safety and efficacy, the FDA has issued a communication urging clinicians to remove filters (optimally, within 90 days post-implantation). According to national data retrieval rates remain low. Our study aimed to assess IVC filter retrieval rates and factors that influence retrieval. Methods: This is a single center, retrospective cohort study of patients who had IVC filter placement between December 2015 and December 2018. Subjects were identified using procedural codes for IVC filter insertion; data regarding demographics, comorbidities, retrieval, IVC filter-related complications and subsequent thromboembolic events were obtained by direct chart review. Survival analyses and a Cox regression model were performed using JMP statistical software. Results: Over 3 years, 494 patients with IVC filters were identified; 305 (62%) were retrievable. The average age at placement was 69±16 years; 249 (50%) were men and 332 (67%) were Caucasian. After excluding patients who died or were lost to follow-up within 30 days of placement or were discharged to hospice from the index admission, 258 patients with retrievable filters remained (54 retrieved). Indications for IVC filter placement were PE ± DVT 90 (35%), proximal DVT 159 (62%) and prophylactic 9 (3%). Forty two percent of patients (109) were restarted on AC at discharge, while an additional 18% (total 155) received AC at some point thereafter. The rate of retrieval was 8% at 90 days, 23% at 1 year and 28% at 2 years (Figure A). The proportional hazards model identified resumption of AC at any time (HR 3.11, 95%CI 1.6-6.8, p=0.0006) as the strongest predictor of retrieval; AC at discharge was not predictive. Advanced age at placement (HR 0.97 per unit change, 0.96-0.99, p=0.004) and active malignancy (HR 0.5, 95%CI 0.24-0.98, p=0.04) were associated with a lower likelihood of retrieval. The initial thrombotic event, the reversibility of the contraindication to AC, the placing service, sex, ethnicity and other comorbid conditions did not have an impact on retrieval. Kaplan-Meier analysis revealed that subjects who ever resumed AC had significantly higher rates of retrieval at 90 days (11% vs 3.4%) and at 1 year (33% vs 9.7%, log-rank p=0.0003, Figure B) when compared to those who did not. Only four patients experienced IVC filter-related complications (2 filter thrombosis, 1 IVC penetration, 1 device tilting); all occurred 2 or more years after placement. Recurrent thromboembolic events occurred in 50 patients (5 PE, 48 proximal DVT) with no significant difference in frequency between subjects with retrieved and non-retrieved filters; one PE and one DVT occurred at 1 month and 1 week respectively after retrieval. Conclusion: Despite efforts to increase awareness of IVC filter-associated complications, the unweighted retrieval rate remained below the nationally reported average of 30%. Persistent risk factors for thrombosis such as active malignancy or increasing age and poor prognosis may play a role in the decision to defer retrieval. In our study, resumption of AC proved a powerful predictor of retrieval, with rates approaching expected values in this population. Active surveillance for resolution of contraindications to AC post-IVC filter placement is crucial in increasing retrieval rates. Figure Disclosures No relevant conflicts of interest to declare.


2019 ◽  
Vol 70 (2) ◽  
pp. 193-198 ◽  
Author(s):  
Ramin Hamidizadeh ◽  
David Liu ◽  
Faisal Khosa ◽  
John Chung ◽  
Darren Klass ◽  
...  

Purpose To conduct a retrospective review and quality assurance study of inferior vena cava (IVC) filter retrieval over a two-year period at a tertiary care centre. Methods Patients who underwent IVC filter placement or retrieval over a two-year period were identified. Medical records were reviewed for patient characteristics, filter indication, time to filter retrieval, and complications. Results IVC filters were placed in 229 patients between January 1, 2015 and December 31, 2016. 113 retrievals were attempted and 101 filters were successfully retrieved (89.4%). Median time to first retrieval attempt was 48 days (range of 5–728). Seventy-one patients died in the interval after filter insertion before a retrieval attempt at a median time of 27 days (range of 3–430). In 17 patients, retrieval was complicated by or delayed because of penetration of IVC wall (n = 6), large thrombus burden trapped by filter (n = 5), filter tilt or migration (n = 3), and unclear reasons (n = 3). Time-to-first unsuccessful retrieval attempt was 141 days (median). Of all filters placed, 55.9% were never retrieved. Excluding deceased patients with in-situ filters (n = 71) and unsuccessful retrievals left in-situ as permanent filters (n = 5), there remains 52 patients (33%), with a median filter in-situ time of 488 days. Conclusion Our study indicates that as many as 33% of patients may have been lost to follow-up of their in-situ IVC filter. Considering widespread reports of long-term complications and the recent safety alert issued by Health Canada, it is evident that a unified strategy is needed to track patients post filter insertion.


2019 ◽  
Vol 92 (1100) ◽  
pp. 20190051 ◽  
Author(s):  
Luisa Peress ◽  
Sally Kamil ◽  
Maria Fernandez ◽  
Rowena Lastimosa ◽  
Ounali Jaffer ◽  
...  

Objective: To review inferior vena cava (IVC) filter retrieval practice at our institution, the Royal London Hospital, and measure changes following a quality improvement intervention. IVC filters are a preventive treatment for pulmonary embolism when anticoagulation is ineffective/contraindicated. Unless permanent filtration is required, all filters should undergo attempted retrieval within manufacturer’s recommendations with a success rate of ≥80 %. Methods: Retrospective audit of filters inserted between 2011 and 2014, followed by a quality improvement intervention and a second audit between 2015 and 2017. Clinical–radiological data were analysed using the Picture Archiving and Communication System and electronic patient records. Results: During the first audit, filter retrieval was attempted in 92% of cases, of which 82% underwent the procedure within manufacturer's recommendations and 86% were successful. During the second audit, an improvement across indicators was seen. Retrieval increased by 3% and was attempted in 95% of cases (92% of which were within manufacturer’s guidelines). Rate of retrievals within manufacturer’s guidelines increased by 10%. Filter retrieval success rate increased by 11% - to 97%. Conclusions: IVC filter retrieval practice at a single institution can be improved by implementing a simple audit intervention. Advances in knowledge: Filter retrieval practice has clinical and medicolegal implications. A simple quality intervention can substantially improve overall practice.


2016 ◽  
Vol 22 (1) ◽  
pp. 51-56 ◽  
Author(s):  
John P Winters ◽  
Christopher S Morris ◽  
Chris E Holmes ◽  
Patricia Lewis ◽  
Anant D Bhave ◽  
...  

Published reports indicate low retrieval rates for retrievable inferior vena cava (IVC) filters. We performed a historic-controlled study of a 5-year intervention (March 2007 to February 2012) to improve IVC filter retrieval rates at a university medical center serving a rural area. All adults with a retrievable filter placed were included, except those with a life expectancy <6 months. The intervention included initial verbal counseling and printed educational materials, correspondence after discharge, and a hematology consultation. The control group included patients with retrievable filters placed in the 15 months preceding study initiation. In the control group, 116 filters were placed and 27 (23%) were removed, compared to 378 filters placed and 169 (45%) removed during the intervention. Adjusting for patient characteristics, the odds ratio of retrieval during the intervention was 3.03 (95% CI 1.85–4.27) compared to the control period. An intervention including patient education and hematology follow-up appeared to significantly improve IVC filter retrieval rates.


2014 ◽  
Vol 30 (8) ◽  
pp. 549-556 ◽  
Author(s):  
Eun Cho ◽  
Kyung Jae Lim ◽  
Jeong Hyun Jo ◽  
Gyoo-Sik Jung ◽  
Byeong Ho Park

Objectives To evaluate the complications of the temporary implanted inferior vena cava (IVC) filter and the feasibility of double-loop technique for removal of complicated IVC filters. Methods From January 2012 to December 2013, a total of 25 patients with IVC filter were referred for IVC filter retrieval. There were 20 Celect®, 3 OptEase®, and 2 Günther-Tulip® filters. All of the patients were evaluated with a pre-procedural CT scan to identify any complications. The IVC filters which had failed to be retrieved by the conventional method were evaluated, and retrieval was attempted with double loop technique. Results Sixteen of 25 (64%) filters had complications; IVC wall penetration ( n = 11, 44%), tilted within IVC ( n = 6, 24%), embedded struts ( n = 3, 12%), and fracture of the strut ( n = 1, 4%). The complications were overlapped in five patients. Two of them (8%) had also complained of filter-related pain. The success rate of IVC filter retrieval by double-loop technique was 14/16 (87.5%). There was no major filter retrieval-related complications. Conclusions The double-loop technique is a safe and feasible method for complicated IVC filter retrieval.


VASA ◽  
2011 ◽  
Vol 40 (2) ◽  
pp. 157-162 ◽  
Author(s):  
Piecuch ◽  
Wiewiora ◽  
Nowowiejska-Wiewiora ◽  
Szkodzinski ◽  
Polonski

The placement of an inferior vena cava (IVC) filter is a therapeutic method for selected patients with deep venous thrombosis and pulmonary embolism. However, insertion and placement of the filter may be associated with certain complications. For instance, retroperitoneal hematoma resulting from perforation of the wall by the filter is such a very rare but serious complication. We report the case of a 64-year-old woman with perforation of the IVC wall and consecutive hematoma caused by the filter who was treated surgically.


2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Masatoshi Narikawa ◽  
Masayoshi Kiyokuni ◽  
Junya Hosoda ◽  
Toshiyuki Ishikawa

Abstract Background Transseptal puncture and pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) are generally performed via the inferior vena cava (IVC). However, in cases where the IVC is inaccessible, a specific strategy may be needed. Case summary An 86-year-old woman with paroxysmal AF and an IVC filter in situ was referred to our hospital for ablation therapy. An IVC filter for pulmonary embolism and deep venous thrombosis had been implanted 15 years prior, therefore we selected a transoesophageal echocardiography (TOE)-guided transseptal puncture using a superior vena cava (SVC) approach. After the single transseptal puncture, we performed fast anatomical mapping, voltage mapping by multipolar mapping catheter, and then PVI by contact force-guided radiofrequency catheter using a steerable sheath. Following the ablation, bidirectional conduction block between the four pulmonary veins and the left atrium was confirmed by both radiofrequency and mapping catheter. No complications occurred and no recurrence of AF was documented in the 12 months after the procedure. Discussion When performing a transseptal puncture during AF ablation, an SVC approach, via access through the right internal jugular vein, enables the sheath to directly approach the left atrium without angulation and improves operability of the ablation catheter. Combining the use of general anaesthesia, TOE, a steerable sheath, and contact force-guided ablation may contribute to achieving minimally invasive PVI with a single transseptal puncture via an SVC approach.


Sign in / Sign up

Export Citation Format

Share Document