Is intervertebral disc degeneration related to segmental instability? An evaluation with two different grading systems based on clinical imaging

2017 ◽  
Vol 59 (3) ◽  
pp. 327-335 ◽  
Author(s):  
David Volkheimer ◽  
Fabio Galbusera ◽  
Christian Liebsch ◽  
Sabine Schlegel ◽  
Friederike Rohlmann ◽  
...  

Background Several in vitro studies investigated how degeneration affects spinal motion. However, no consensus has emerged from these studies. Purpose To investigate how degeneration grading systems influence the kinematic output of spinal specimens. Material and Methods Flexibility testing was performed with ten human T12-S1 specimens. Degeneration was graded using two different classifications, one based on X-ray and the other one on magnetic resonance imaging (MRI). Intersegmental rotation (expressed by range of motion [ROM] and neutral zone [NZ]) was determined in all principal motion directions. Further, shear translation was measured during flexion/extension motion. Results The X-ray grading system yielded systematically lesser degeneration. In flexion/extension, only small differences in ROM and NZ were found between moderately degenerated motion segments, with only NZ for the MRI grading reaching statistical significance. In axial rotation, a significant increase in NZ for moderately degenerated segments was found for both grading systems, whereas the difference in ROM was significant only for the MRI scheme. Generally, the relative increases were more pronounced for the MRI classification compared to the X-ray grading scheme. In lateral bending, only relatively small differences between the degeneration groups were found. When evaluating shear translations, a non-significant increase was found for moderately degenerated segments. Motion segment segments tended to regain stability as degeneration progressed without reaching the level of statistical significance. Conclusion We found a fair agreement between the grading schemes which, nonetheless, yielded similar degeneration-related effects on intersegmental kinematics. However, as the trends were more pronounced using the Pfirrmann classification, this grading scheme appears superior for degeneration assessment.

2022 ◽  
pp. 1-9

OBJECTIVE The traditional anterior approach for multilevel severe cervical ossification of the posterior longitudinal ligament (OPLL) is demanding and risky. Recently, a novel surgical procedure—anterior controllable antedisplacement and fusion (ACAF)—was introduced by the authors to deal with these problems and achieve better clinical outcomes. However, to the authors’ knowledge, the immediate and long-term biomechanical stability obtained after this procedure has never been evaluated. Therefore, the authors compared the postoperative biomechanical stability of ACAF with those of more traditional approaches: anterior cervical discectomy and fusion (ACDF) and anterior cervical corpectomy and fusion (ACCF). METHODS To determine and assess pre- and postsurgical range of motion (ROM) (2 Nm torque) in flexion-extension, lateral bending, and axial rotation in the cervical spine, the authors collected cervical areas (C1–T1) from 18 cadaveric spines. The cyclic fatigue loading test was set up with a 3-Nm cycled load (2 Hz, 3000 cycles). All samples used in this study were randomly divided into three groups according to surgical procedures: ACDF, ACAF, and ACCF. The spines were tested under the following conditions: 1) intact state flexibility test; 2) postoperative model (ACDF, ACAF, ACCF) flexibility test; 3) cyclic loading (n = 3000); and 4) fatigue model flexibility test. RESULTS After operations were performed on the cadaveric spines, the segmental and total postoperative ROM values in all directions showed significant reductions for all groups. Then, the ROMs tended to increase during the fatigue test. No significant crossover effect was detected between evaluation time and operation method. Therefore, segmental and total ROM change trends were parallel among the three groups. However, the postoperative and fatigue ROMs in the ACCF group tended to be larger in all directions. No significant differences between these ROMs were detected in the ACDF and ACAF groups. CONCLUSIONS This in vitro biomechanical study demonstrated that the biomechanical stability levels for ACAF and ACDF were similar and were both significantly greater than that of ACCF. The clinical superiority of ACAF combined with our current results showed that this procedure is likely to be an acceptable alternative method for multilevel cervical OPLL treatment.


2012 ◽  
Vol 42 (11) ◽  
pp. 2005-2010
Author(s):  
Antonio Cezar de Oliveira Dearo ◽  
Vitor Bruno Bianconi Rosa ◽  
Peter Reichmann ◽  
Milton Luis Ribeiro de Oliveira

Deep digital flexor (DDF) tenotomy is a technique employed for years to treat selected disorders of the musculoskeletal system in horses. Although two different surgical approaches (i.e. mid-metacarpal and pastern) have been described for performing the procedure, in vitro quantitative data regarding the modifications induced by either technique on the distal articular angles is lacking. Therefore, the purpose of the study reported here was to investigate the viability of a proposed biomechanical system of induced-traction used to compare the two DDF tenotomy techniques by measuring the distal articular angles of equine cadaver forelimbs. Ten pairs of forelimbs were collected and mounted to a biomechanical system developed to apply traction at the toe level. Dorsal articular angles of the metacarpophalangeal (MP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints were determined by geometric lines on radiographs taken before and after performing each technique. Comparisons between each tenotomy group and its own control, for each joint, and between the two tenotomy groups using as variable the difference between the tenotomy and control groups were tested. Despite the lack of statistical significance, the DDF tenotomy technique at the pastern level produced extension, to a lesser and greater extent, of the PIP and DIP joints, respectively when compared to the mid-metacarpal level. No remarkable differences could be observed for the MP joint. The developed traction-induced biomechanical construct seemed to be effective in producing valuable quantitative estimations of the distal articular angles of equine cadaver forelimbs subjected to different DDF tenotomy techniques.


2018 ◽  
Vol 15 (148) ◽  
pp. 20180550
Author(s):  
Vahhab Zarei ◽  
Rohit Y. Dhume ◽  
Arin M. Ellingson ◽  
Victor H. Barocas

Due to its high level of innervation, the lumbar facet capsular ligament (FCL) is suspected to play a role in low back pain (LBP). The nociceptors in the lumbar FCL may experience excessive deformation and generate pain signals. As such, understanding the mechanical behaviour of the FCL, as well as that of its underlying nerves, is critical if one hopes to understand its role in LBP. In this work, we constructed a multiscale structure-based finite-element (FE) model of a lumbar FCL on a spinal motion segment undergoing physiological motions of flexion, extension, ipsilateral and contralateral bending, and ipsilateral axial rotation. Our FE model was created for a generic FCL geometry by morphing a previously imaged FCL anatomy onto an existing generic motion segment model. The fibre organization of the FCL in our models was subject-specific based on previous analysis of six dissected specimens. The fibre structures from those specimens were mapped onto the FCL geometry on the motion segment. A motion segment model was used to determine vertebral kinematics under specified spinal loading conditions, providing boundary conditions for the FCL-only multiscale FE model. The solution of the FE model then provided detailed stress and strain fields within the tissue. Lastly, we used this computed strain field and our previous studies of deformation of nerves embedded in fibrous networks during simple deformations (e.g. uniaxial stretch, shear) to estimate the nerve deformation based on the local tissue strain and fibre alignment. Our results show that extension and ipsilateral bending result in largest strains of the lumbar FCL, while contralateral bending and flexion experience lowest strain values. Similar to strain trends, we calculated that the stretch of the microtubules of the nerves, as well as the forces exerted on the nerves' membrane are maximal for extension and ipsilateral bending, but the location within the FCL of peak microtubule stretch differed from that of peak membrane force.


2009 ◽  
Vol 32 (2) ◽  
pp. 141-151 ◽  
Author(s):  
Pierre-Michel Dugailly ◽  
Stéphane Sobczak ◽  
Victor Sholukha ◽  
Serge Van Sint Jan ◽  
Patrick Salvia ◽  
...  

Neurosurgery ◽  
2001 ◽  
Vol 49 (6) ◽  
pp. 1399-1408 ◽  
Author(s):  
Andrzej Maciejczak ◽  
Michał Ciach ◽  
Maciej Radek ◽  
Andrzej Radek ◽  
Jan Awrejcewicz

ABSTRACT OBJECTIVE To determine whether the Cloward technique of cervical discectomy and fusion increases immediate postoperative stiffness of single cervical motion segment after application of interbody dowel bone graft. METHODS We measured and compared the stiffness of single-motion segments in cadaveric cervical spines before and immediately after interbody fusion with the Cloward technique. Changes in range of motion and stiffness of the C5–C6 segment were measured in a bending flexibility test (flexion, extension, lateral bending and axial rotation) before and after a Cloward procedure in 11 fresh-frozen human cadaveric specimens from the 4th through the 7th vertebrae. RESULTS The Cloward procedure produced a statistically significant increase in stiffness of the operated segment in flexion and lateral bending when compared with the intact spine. The less stiff the segment before the operation, the greater the increase in its postoperative flexural stiffness (statistically significant). The Cloward procedure produced nonuniform changes in rotational and extensional stiffness that increased in some specimens and decreased in others. CONCLUSION Our data demonstrate that Cloward interbody fusion increases immediate postoperative stiffness of an operated segment only in flexion and lateral bending in cadaveric specimens in an in vitro environment. Thus, Cloward fusion seems a relatively ineffective method for increasing the stiffness of a construct. This may add to discussion on the use of spinal instrumentation and postoperative management of patients after cervical discectomy, which varies from bracing in hard collars through immobilization in soft collars to no external orthosis.


2008 ◽  
Vol 43 (1) ◽  
pp. 6-13 ◽  
Author(s):  
Gianluca Del Rossi ◽  
Mary Beth H. Horodyski ◽  
Bryan P. Conrad ◽  
Christian P. Di Paola ◽  
Matthew J. Di Paola ◽  
...  

Abstract Context: To achieve full spinal immobilization during on-the-field management of an actual or potential spinal injury, rescuers transfer and secure patients to a long spine board. Several techniques can be used to facilitate this patient transfer. Objective: To compare spinal segment motion of cadavers during the execution of the 6-plus–person (6+) lift, lift-and-slide (LS), and logroll (LR) spine-board transfer techniques. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Eight medical professionals (1 woman, 7 men) with 5 to 32 years of experience were enlisted to help carry out the transfer techniques. In addition, test conditions were performed on 5 fresh cadavers (3 males, 2 females) with a mean age of 86.2 ± 11.4 years. Main Outcomes Measure(s): Three-dimensional angular and linear motions initially were recorded during execution of transfer techniques, initially using cadavers with intact spines and then after C5-C6 spinal segment destabilization. The mean maximal linear displacement and angular motion obtained and calculated from the 3 trials for each test condition were included in the statistical analysis. Results: Flexion-extension angular motion, as well as anteroposterior and distraction-compression linear motion, did not vary between the LR and either the 6+ lift or LS. Compared with the execution of the 6+ lift and LS, the execution of the LR generated significantly more axial rotation (P  =  .008 and .001, respectively), more lateral flexion (P  =  .005 and .003, respectively), and more medial-lateral translation (P  =  .003 and .004, respectively). Conclusions: A small amount of spinal motion is inevitable when executing spine-board transfer techniques; however, the execution of the 6+ lift or LS appears to minimize the extent of motion generated across a globally unstable spinal segment.


1985 ◽  
Vol 249 (1) ◽  
pp. F99-F106 ◽  
Author(s):  
N. Farman ◽  
J. P. Bonvalet

The binding of aldosterone was studied in tubular segments isolated by microdissection from kidneys of spontaneously hypertensive (SHR, n = 8), Kyoto normotensive (KWR, n = 8), and normal Wistar (NWR, n = 6) rats with an autoradiographic technique on dry film. All animals had been previously adrenalectomized. Kidney pyramids were incubated in vitro before microdissection with collagenase and 2 X 10(-9) M [3H]aldosterone in the presence or absence of an excess of unlabeled aldosterone. In addition, the displacement of the binding by 10 times excess dexamethasone or aldosterone was examined in the cortical and medullary collecting tubule of SHR and KWR to assess the specificity of binding sites. In the three groups, no specific nuclear labeling was detectable in the proximal tubule. The highest specific nuclear labeling was found in the distal portions of the nephron, and intermediate values were present along the loop of Henle. In the cortical collecting tubule, the most specific mineralocorticoid segment, the specific nuclear binding, expressed in silver grains per unit surface, was significantly elevated in SHR (16.1 +/- 1.5) and KWR (13.7 +/- 1.5) as compared with NWR (10.2 +/- 0.8, P less than 0.001 and less than 0.05, respectively). The difference between SHR and KWR did not reach statistical significance. In the medullary collecting tubule, binding was higher in SHR (14.3 +/- 1.6) than in both KWR (8.7 +/- 1.0, P less than 0.005) and NWR (10.1 +/- 0.9, P less than 0.025).(ABSTRACT TRUNCATED AT 250 WORDS)


2018 ◽  
Vol 27 (1) ◽  
pp. 24-29 ◽  
Author(s):  
Jae Guk Kim ◽  
Sung Hwan Bang ◽  
Gu Hyun Kang ◽  
Yong Soo Jang ◽  
Wonhee Kim ◽  
...  

Background: The cervical collar has been used as a common device for the initial stabilization of the cervical spine. Although many cervical collars are commercially available, there is no consensus on which offers the greatest protection, with studies showing considerable variations in their ability to restrict cervical range of motion. The use of the XCollar (Emegear, Carpinteria, CA) has been known to decrease the risk of spinal cord injury by minimizing potential cervical spinal distraction. We compared XCollar with two other cervical collars commonly used for adult patients with cervical spine injury to evaluate the difference in effectiveness between the three cervical collars to restrict cervical range of motion. Objectives: This study aimed to evaluate the difference between the three cervical collars in their ability to restrict cervical range of motion. Method: A total of 30 healthy university students aged 21–25 years participated in this study. Participants with any cervical disease and symptoms were excluded. Three cervical collars were tested: Philadelphia® Collar, Stifneck® Select™ Collar, and XCollar. A digital camera and an image-analysis technique were used to evaluate cervical range of motion during flexion, extension, bilateral bending and bilateral axial rotation. Cervical range of motion was evaluated in both the unbraced and braced condition. Results: XCollar permitted less than a mean of 10° of movement during flexion, extension, bilateral bending and bilateral axial rotation. This was less than the movement permitted by the other two cervical collars. Conclusion: XCollar presented superior cervical immobilization compared to the other two commonly used cervical collars in this study. Thus, when cervical collar is considered for an adult patient with cervical spine injury, XCollar might be one of the considerate options as a cervical immobilization device.


2019 ◽  
Vol 9 (8) ◽  
pp. 826-833
Author(s):  
Ripul Panchal ◽  
Anup Gandhi ◽  
Chris Ferry ◽  
Sam Farmer ◽  
Jeremy Hansmann ◽  
...  

Study Design: In vitro biomechanical study. Objectives: The objective of this in vitro biomechanical range-of-motion (ROM) study was to evaluate spinal segmental stability following fixation with a novel anterior cervical discectomy and fusion (ACDF) device (“novel device”) that possesses integrated and modular no-profile, half-plate, and full-plate fixation capabilities. Methods: Human cadaveric (n = 18, C3-T1) specimens were divided into 3 groups (n = 6/group). Each group would receive one novel device iteration. Specimen terminal ends were potted. Each specimen was first tested in an intact state, followed by anterior discectomy (C5/C6) and iterative instrumentation. Testing order: (1) novel device (group 1, no-profile; group 2, half-plate; group 3, full-plate); (2) novel device (all groups) with lateral mass screws (LMS); (3) traditional ACDF plate + cage; (4) traditional ACDF plate + cage + LMS. A 2 N·m moment was applied in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) via a kinematic testing machine. Segmental ROM was tracked and normalized to intact conditions. Comparative statistical analyses were performed. Results: Key findings: (1) the novel half- and full-plate constructs provided comparable reduction in FE and LB ROM to that of traditional plated ACDF ( P ≥ .05); (2) the novel full-plate construct significantly exceeded all other anterior-only constructs ( P ≤ .05) in AR ROM reduction; and (3) the novel half-plate construct significantly exceeded the no-profile construct in FE ( P < .05). Conclusions: The novel ACDF device may be a versatile alternative to traditional no-profile and independent plating techniques, as it provides comparable ROM reduction in all principle motion directions, across all device iterations.


2014 ◽  
Vol 10 (3) ◽  
pp. 412-417 ◽  
Author(s):  
Marco T. Reis ◽  
Phillip M. Reyes ◽  
Neil R. Crawford

Abstract BACKGROUND: A new anchored cervical interbody polyetheretherketone spacer was devised that uses only 2 integrated variable-angle screws diagonally into the adjacent vertebral bodies instead of the established device that uses 4 diagonal fixed-angle screws. OBJECTIVE: To compare in vitro the stability provided by the new 2-screw interbody spacer with that of the 4-screw spacer and a 4-screw anterior plate plus independent polyetheretherketone spacer. METHODS: Three groups of cadaveric specimens were tested with 2-screw anchored cage (n = 8), 4-screw anchored cage (n = 8), and standard plate/cage (n = 16). Pure moments (1.5 Nm) were applied to induce flexion, extension, lateral bending, and axial rotation while measuring 3-D motion optoelectronically. RESULTS: In all 3 groups, the mean range of motion (ROM) and lax zone were significantly reduced relative to the intact spine after discectomy and fixation. The 2-screw anchored cage allowed significantly greater ROM (P &lt; .05) than the standard plate during flexion, extension, and axial rotation and allowed significantly greater ROM than the 4-screw cage during extension and axial rotation. The 4-screw anchored cage did not allow significantly different ROM or lax zone than the standard plate during any loading mode. CONCLUSION: The 2-screw variable-angle anchored cage significantly reduces ROM relative to the intact spine. Greater stability can be achieved, especially during extension and axial rotation, by using the 4-screw cage or standard plate plus cage.


Sign in / Sign up

Export Citation Format

Share Document