Cyclic Test of Concrete Bridge Column Utilizing Ultra-High Performance Concrete Shell

Author(s):  
Nerma Caluk ◽  
Islam M. Mantawy ◽  
Atorod Azizinamini

Ultra-high performance concrete (UHPC) is a durable material that can be used in constructing new and unique structural elements. This research utilizes UHPC to construct prefabricated shells that act as stay-in-place forms for bridge columns and eliminate the use of traditional formwork. These innovative structural elements reduce the on-site construction time, improve the structural performance of the column, and act as a protective layer in aggressive environments. Generally, during the construction process, the prefabricated UHPC shell is placed around the column reinforcement, which is fabricated using conventional methods. To connect the UHPC shell and column reinforcement with the footing and footing dowels, a step made of UHPC is utilized. The UHPC step connection is designed to shift the plastic hinge away from the column-to-footing interface. In the next stage, normal concrete is cast inside the shell, forming a concrete-filled UHPC shell. The final stage of construction involves placing and connecting a prefabricated cap-beam using the same UHPC step connection. The column specimen was tested under constant axial load and incremental lateral load. In this test, the UHPC shell cracked on the north side at a drift ratio of 3%; however, the column had a significant capacity and behaved similarly to a conventional reinforced concrete column during higher cycles of drift ratios. The test was completed after the column had reached a drift ratio of 7.5% when the first bar ruptured. No damage occurred in the footing and UHPC step which proved that the design was successful in shifting the plastic hinge away from the column-to-footing interface.

2020 ◽  
Vol 10 (2) ◽  
pp. 153-164
Author(s):  
Hui Zheng ◽  
Dongdong Zhou ◽  
Xinfeng Yin ◽  
Lei Wang

Ultra-high-performance concrete (UHPC) material, a new type of cement-based composite material, is usually employed in the bridge engineering. The transfer and anchorage length of steel strand in UHPC material is different from that in ordinary concrete; nevertheless, few design standards are found that how to anchor the transfer and anchoring length of steel strand in UHPC material under normal curing. Through central pull-out test under the different conditions of protective layer thickness and embedded length, the load-slip curves, failure modes, and bond strength of 36 UHPC material specimens under normal curing were studied. The experimental results showed that the ultimate bond stress between UHPC material and steel strand under natural curing conditions is 7.01∼11.68 MPa. When the compressive strength of cube was 157 MPa; the bond strength under natural curing was smaller than that under thermal curing; when the thickness of the protective layer of steel strand with a diameter of 15.2 mm is greater than 30 mm, it had a little influence on bond strength. The regression analysis of the test results based on the experimental results proves that the recommended formulas for the design of transfer length and anchorage length of steel strand in UHPC material were in great agreement with the results of published studies.


2014 ◽  
Vol 578-579 ◽  
pp. 776-778
Author(s):  
Petr Tej ◽  
Jiří Kolísko ◽  
Petr Bouška ◽  
Miroslav Vokáč ◽  
Jindřich Čech

This paper focuses on research into prestressed I-beams made of ultra-high-performance concrete, which are designed to be structural elements in small and medium span railway bridges. Prestressed concrete I-beams are designed with ten prestressing cables in the bottom flange. The prestressed beams are laid close together in the actual structure with panels inserted between them. The entire structure will subsequently become monolithic. At the present time, I-beams made of rolled steel are commonly used as structural elements in this type of structure. The advantage of these types of structures lies in their having a low construction height. This paper presents a computer and experimental analysis of the loading of UHPC prestressed I-beams. For the purpose of the experiments, several specimens of 7 m span were made. The specimens were subsequently tested in the laboratory in four-point bending tests. The paper presents the process and results of the experiments. Simultaneously with the experiments, computer analyses were created in which optimization of the material and geometric parameters of the beams were carried out. The paper demonstrates the correspondence of the experimental and computer-simulated load test results.


Author(s):  
Mohamadreza Shafieifar ◽  
Mahsa Farzad ◽  
Atorod Azizinamini

Accelerated bridge construction (ABC) is a paradigm change in delivery of bridges. ABC minimizes the traffic interruption, enhances safety to public and workers by significantly reducing on-site construction activities, and results in longer-lasting bridges. The use of precast elements is gaining attention owing to inherent benefits of accelerated construction. Designing an economical connection is one of the main concerns for these structures. New improved materials such as ultra-high-performance concrete (UHPC) with superior characteristics can provide solutions for joining precast concrete elements. In this paper two types of column to cap beam connection using UHPC are proposed for seismic and non-seismic regions. Among the merits of the proposed details, large tolerances in construction and simplicity of the connection can be highlighted which facilitates and accelerates the on-site construction time. The experimental program was carried out to evaluate the performance and structural behavior of the proposed connections. Four specimens were subjected to constant axial compressive loads and cyclic lateral loading. Results of the experiment showed that the displacement ductility of the specimens, incorporating suggested details, demonstrated adequate levels of displacement ductility. More importantly, the proposed connections prevented the damage into capacity protected element—in this case the cap beam. Analytical and nonlinear finite element analysis on the specimens was carried out to better comprehend the behavior of the proposed connections.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Matej Špak ◽  
Mária Kozlovská ◽  
Zuzana Struková ◽  
Renáta Bašková

Nowadays, high-performance concrete (HPC) and ultra-high-performance concrete (UHPC) are ranked among advanced concrete technologies. The application of the mentioned advanced technologies may have potential to improve the construction efficiency from several points of view. For instance, reducing of construction time and construction material, construction quality improving, environmental impact minimizing, and increasing of both durability and lifetime of structures as well as reducing of total construction costs may be obtained. Particular advanced concrete technologies are described and the possibilities of their utilization in both monolithic structures and precast units are presented in the article. The main benefits of modern methods of construction (MMC) based on advanced concrete technologies application in precast elements production are presented. Regarding the selected aspects of construction efficiency assessment, a comparison of conventional and advanced concrete technologies that are applied in monolithic structures and precast units is made. The results of this comparison, estimated in semantic differential scale, are presented in the article. By the results of the comparison, the significance of applying the advanced concrete technologies in modern methods of concrete structures production is demonstrated in order to improve construction efficiency.


2015 ◽  
Vol 1106 ◽  
pp. 8-13 ◽  
Author(s):  
Petr Koukolík ◽  
Jan L. Vítek ◽  
Robert Brož ◽  
Robert Coufal ◽  
Milan Kalný ◽  
...  

Footbridge over the Labe River in Celakovice is a cable stayed structure with the main span 156 m long. It is designed for pedestrians, cyclists and also a light utility vehicle may pass over the footbridge. Until now, the footbridge has a record span of the cable stayed structure in the Czech Republic. The ultra high performance concrete (UHPC) was first applied for the load carrying structure on the footbridge at the Czech Republic. The pylons are made of steel and the stays are made of locked coil strands. Since no obligatory codes were available for the design of structures made of UHPC, the extensive experimental verification of material parameters and structural elements was necessary.


2019 ◽  
Vol 4 (2) ◽  
pp. 25 ◽  
Author(s):  
Nerma Caluk ◽  
Islam Mantawy ◽  
Atorod Azizinamini

Ultra-high performance concrete (UHPC) is a durable material that allows the construction of innovative structural elements and conforms with accelerated bridge construction (ABC) goals. The main idea of this research is to utilize UHPC to prefabricate a shell that acts as a stay-in-place form for bridge columns. The prefabricated shell eliminates the conventional formwork while reducing the on-site construction time and acting as a durable protective layer for the normal concrete inside the shell against environmental attacks. In addition, the UHPC shell provides additional confinement to the column concrete, which improves the column’s structural performance. During construction and after completing the column reinforcement work onsite, based on the conventional construction methods, the prefabricated UHPC shell is placed around the column reinforcement, followed by casting a portion of UHPC for a column-to-footing connection, which improves the capacity of the connection and shifts the plastic hinge zone above the connection. Once the UHPC portion hardens, normal concrete is placed inside the shell, forming a permanent concrete-filled UHPC shell. The construction process is finalized by placing and connecting a prefabricated cap beam to the column through the same developed connection as that in this research. This technical note presents the development of two test specimens using an UHPC shell in lieu of a conventional formwork with the advantage of improving the column performance and durability.


2014 ◽  
Vol 587-589 ◽  
pp. 1593-1596
Author(s):  
Petr Tej ◽  
Jiří Kolísko ◽  
Petr Bouška ◽  
Miroslav Vokáč ◽  
Jindřich Čech

This paper focuses on research of prestressed I-beams made of ultra-high performance concrete (UHPC), which are designed to be structural elements in small and medium span railway bridges. Prestressed concrete I-beams are designed with ten prestressing cables in the bottom flange. The prestressed beams are laid close together in the actual structure, with panels inserted between them. The entire structure will subsequently become monolithic. At the present time, I-beams made of rolled steel are commonly used as structural elements in this type of structure. The advantage of these types of structures lies in their having low construction height. This paper presents a computer and experimental analysis of loading of UHPC prestressed I-beams. For the purpose of the experiments, three specimens of 12 m span were made. The specimens were subsequently tested in the laboratory in four-point bending tests. The paper presents the process and results of the experiments. Simultaneously with the experiments, computer analyses were created in which optimization of the material and geometric parameters of the beams were carried out. The paper demonstrates the correspondence of the experimental and computer-simulated load test results.