Behavior and pressure drop of an upwardly two-phase flow through multi-hole orifices

Author(s):  
Ammar Zeghloul ◽  
Abdelwahid Azzi ◽  
Abbas Hasan ◽  
Barry James Azzopardi

Experimental results on hydrodynamic behavior and pressure drop of two-phase mixture flowing upwardly in a pipe containing single- and/or multi-hole orifice plate are presented. It was found from the measurement of the void fraction upstream and downstream the orifices that the flow behavior is significantly affected by the layout of the orifice plate used and the flow starts to recover after approximately 7 D downstream the orifice. Furthermore, increasing orifice holes number results in decreasing the slip ratio. The standard deviation of the void fraction was used to identify the flow pattern before and after the orifices and found that the critical threshold transition occurred at a standard deviation of 0.2. The flow homogenization necessitates a minimum value of the liquid superficial velocity to occur, and the position where it takes place depends on this velocity and on the orifice holes number. It was also inferred from the two-phase pressure drop data across the orifices that three different flow regimes, where the transition between bubbly-to-slug and slug-to-churn flow, can be identified. An assessment of the predicted two-phase flow multiplier using some previous models dedicated to single-hole orifice was achieved; and found that the model proposed by Simpson et al. is the most reliable one. Single-phase pressure drop was also measured and compared with correlations from literature.

2016 ◽  
Vol 94 ◽  
pp. 422-432 ◽  
Author(s):  
N. Chikhi ◽  
R. Clavier ◽  
J.-P. Laurent ◽  
F. Fichot ◽  
M. Quintard

1983 ◽  
Vol 105 (4) ◽  
pp. 394-399 ◽  
Author(s):  
H. Pascal

The effect of solution gas on the two-phase flow behavior through an orifice plate and a convergent-divergent nozzle has been investigated with regard to the flow metering of compressible two-phase mixtures. A proper thermodynamics approach to consider more accurately the compressibility effect in an accelerated two-phase flow, in particular that through an orifice and Laval’s nozzle in the presence of the solution gas, has been developed. From this approach an equation of state of mixture was derived and used in determining the orifice equation. An analysis of flow behavior has been performed and several illustrative plots were presented in order to evaluate the gas solubility effect in the flow metering with an orifice plate or a convergent-divergent nozzle. A delimitation between critical and noncritical flow has been established in terms of measured parameters and a relationship between the critical pressure and gas-liquid mass ratio was also shown.


2004 ◽  
Vol 126 (4) ◽  
pp. 546-552 ◽  
Author(s):  
Peter M.-Y. Chung ◽  
Masahiro Kawaji ◽  
Akimaro Kawahara ◽  
Yuichi Shibata

An adiabatic experiment was conducted to investigate the effect of channel geometry on gas-liquid two-phase flow characteristics in horizontal microchannels. A water-nitrogen gas mixture was pumped through a 96 μm square microchannel and the resulting flow pattern, void fraction and frictional pressure drop data were compared with those previously reported by the authors for a 100 μm circular microchannel. The pressure drop data were best estimated using a separated-flow model and the void fraction increased non-linearly with volumetric quality, regardless of the channel shape. However, the flow maps exhibited transition boundaries that were shifted depending on the channel shape.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Agus Sunjarianto Pamitran ◽  
Sentot Novianto ◽  
Normah Mohd-Ghazali ◽  
Nasruddin Nasruddin ◽  
Raldi Koestoer

Two-phase flow boiling pressure drop experiment was conducted to observe its characteristics and to develop a new correlation of void fraction based on the separated model. Investigation is completed on the natural refrigerant R-290 (propane) in a horizontal circular tube with a 7.6 mm inner diameter under experimental conditions of 3.7 to 9.6 °C saturation temperature, 10 to 25 kW/m2 heat flux, and 185 to 445 kg/m2s mass flux. The present experimental data was used to obtain the calculated void fraction which then was compared to the predicted void fraction with 31 existing correlations. A new void fraction correlation for predicting two-phase flow boiling pressure drop, as a function of Reynolds numbers, was proposed. The measured pressure drop was compared to the predicted pressure drop with some existing pressure drop models that use the newly developed void fraction model. The homogeneous model of void fraction showed the best prediction with 2% deviation


Author(s):  
Fumito Kaminaga ◽  
Baduge Sumith ◽  
Kunihito Matsumura

Two-phase pressure drop is experimentally examined in a flow boiling condition in a tube of diameter 1.45 mm using water in ranges of pressure from 10 to 100 kPa, mass flux from 18 to 152 kg/m2s, heat flux from 13 to 646 kW/m2, and exit quality from 0.02 to 0.77. Also, pressure drop in an adiabatic air-water two-phase flow is measured at atmospheric pressure using the same test section and mass flux ranges of liquid and gas as those in the flow boiling. Decreasing system pressure the pressure drop significantly increases at a given mass flux. Influence of vapor phase on the pressure drop is found to be large both in the adiabatic and the diabatic conditions. The frictional pressure drop correlation for the adiabatic two-phase flow is developed and applied to predict pressure drop in the flow boiling. But it cannot give satisfactory predictions. The Chisholm correlation calculating a two-phase pressure drop multiplier is modified to account the influence of vapor phase in a capillary tube and the modified correlation can predict the pressure drop in the flow boiling within an error of 20%.


Author(s):  
Hideo Ide ◽  
Tohru Fukano

Air-liquid two-phase flow in a horizontal flat capillary rectangular channel has been studied to clarify the effects of concentration of surfactant solution on the flow phenomena, such as flow patterns, pressure drop, void fraction and so on. The concentrations of surfactant solution were 0, 10, 50 and 100 ppm and the surface tension of each solution was reduced to about 34mN/m from that of pure water of about 72mN/m. The dimension of the channel used was 10.0 mm × 1.0 mm. The drag reduction by mixing the surfactant was examined in both the single phase flow and the two-phase flow. The experimental data of two-phase frictional pressure drop and holdup were compared with the respective correlations which were previously proposed by the other researchers and the present authors. Finally, we proposed new correlations of two-phase frictional pressure drop and holdup in which the effect of surface tension and the aspect ratio of cross section of channel were taken into account.


2013 ◽  
Vol 135 (8) ◽  
Author(s):  
Wei Liu ◽  
Hidesada Tamai ◽  
Kazuyuki Takase

For a steam generator (SG) in a commercialized sodium-cooled fast breeder reactor (FBR), flow instability in the water side is one of the most important items needing research. As the first step of this research, thermal-hydraulic experiments using water as the test fluid were performed under high pressure conditions at the Japan Atomic Energy Agency (JAEA) by using a circular tube. Void fraction, pressure drop, and heat transfer coefficient data were obtained under 15, 17, and 18 MPa. This paper discusses the steam-water pressure drop and void fraction. Using the obtained data, we evaluated existing correlations for void fraction and two-phase flow multipliers under high pressure. As a result, the drift flux model implemented in the TRAC-BF1 code was confirmed to suitably predict the void fraction well under the present high pressure conditions. For the two-phase flow multiplier, the Chisholm correlation and the homogeneous model were confirmed to be the best under the present high-pressure conditions.


Sign in / Sign up

Export Citation Format

Share Document