scholarly journals A Manikin Study Comparing McGrath Mac® and Airtraq® with Macintosh Laryngoscope in Tracheal Intubation by Intensive Care Unit Doctors

2015 ◽  
Vol 22 (6) ◽  
pp. 337-344 ◽  
Author(s):  
HKW Chan ◽  
OF Wong ◽  
GWM Kwan
2020 ◽  
Vol 25 (1) ◽  
Author(s):  
Ye Sun ◽  
Hua Fan ◽  
Xiao-Xia Song ◽  
Hua Zhang

Abstract Background The present study aimed to compare three fixation methods for orotracheal intubation. Methods Through literature retrieval, the effects of the adhesive/twill tape method, fixator method, and adhesive/twill tape–fixator alternation method on patients with tracheal intubation in the intensive care unit (ICU) were compared. Results The fixator and alternation methods were more effective in protecting the tongue mucosa and teeth. The alternation method was superior to the other two methods in maintaining the position of the endotracheal intubation. However, the difference in facial and lip injuries between the three methods was not statistically significant. Conclusion The fixator method can significantly reduce intraoral injury and is more suitable for older people with weak tongue mucosa and loose teeth. These are worth popularizing among a wider group.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Ryosuke Mihara ◽  
Nobuyasu Komasawa ◽  
Sayuri Matsunami ◽  
Toshiaki Minami

Background.Videolaryngoscopes may not be useful in the presence of hematemesis or vomitus. We compared the utility of the Macintosh laryngoscope (McL), which is a direct laryngoscope, with that of the Pentax-AWS Airwayscope (AWS) and McGRATH MAC (McGRATH), which are videolaryngoscopes, in simulated hematemesis and vomitus settings.Methods.Seventeen anesthesiologists with more than 1 year of experience performed tracheal intubation on an adult manikin using McL, AWS, and McGRATH under normal, hematemesis, and vomitus simulations.Results.In the normal setting, the intubation success rate was 100% for all three laryngoscopes. In the hematemesis settings, the intubation success rate differed significantly among the three laryngoscopes (P=0.021). In the vomitus settings, all participants succeeded in tracheal intubation with McL or McGRATH, while five failed in the AWS trial with significant difference (P=0.003). The intubation time did not significantly differ in normal settings, while it was significantly longer in the AWS trial compared to McL or McGRATH trial in the hematemesis or vomitus settings (P<0.001, compared to McL or McGRATH in both settings).Conclusion.The performance of McGRATH and McL can be superior to that of AWS for tracheal intubation in vomitus and hematemesis settings in adults.


2005 ◽  
Vol 33 ◽  
pp. A121
Author(s):  
Gim Tan ◽  
Lisa Tyler ◽  
Troy E Dominguez ◽  
Cheryl DeFalco ◽  
Vinay Nadkarni ◽  
...  

BMJ Open ◽  
2015 ◽  
Vol 5 (12) ◽  
pp. e009855 ◽  
Author(s):  
Arthur Bailly ◽  
Jean Baptiste Lascarrou ◽  
Aurelie Le Thuaut ◽  
Julie Boisrame-Helms ◽  
Toufik Kamel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document