scholarly journals Home Monitoring with the ClearPlan Easy™ Fertility Monitor for Fertility Awareness

2001 ◽  
Vol 29 (1_suppl) ◽  
pp. 14A-20A ◽  
Author(s):  
K May
Medicina ◽  
2020 ◽  
Vol 56 (11) ◽  
pp. 555
Author(s):  
Stephen J. Usala ◽  
A. Alexandre Trindade

Background and Objectives: Urinary hormone home monitoring assays are now available for fertility awareness methods (FAMs) of family planning, but lack sensitivity and precision in establishing the start of the fertile phase. We hypothesized that with a suitable algorithm, daily serum or blood estradiol (E2) levels could serve as a better analyte to determine the phase of the ovulatory cycle and the fertile start day (FSD). Materials and Methods: Published day-specific serum E2 levels, indexed to the serum luteinizing hormone (LH) peak, were analyzed from three independent laboratories for a threshold for a FSD. A fertility indicator quation (FIE) was discovered and tested with these data and a FSD was determined using the mean or median and variance ranges of the day-specific E2 data. Results: The considerable variance of day-specific serum E2 levels made an absolute serum E2 indicator for phase of cycle problematic. However, a FIE was discovered which maps the day-specific E2 levels of the ovulatory cycle enabling the fertile phase and transition to the luteal phase to be signaled. In this equation, FIE(D) is the value of FIE on day, D, of the cycle and has both a magnitude and sign. The magnitude of FIE(D) is the product of the normalized change in day-specific E2 levels over two consecutive intervals, (D-2, D-1) and (D-1, D), multiplied by 100, and is formulated as: (E2 (on D-1) − E2 (on D-2))/E2 (on D-2) × (E2(on D) − E2 (on D-1))/E2 (on D-1) × 100. The sign of FIE(D) is either + or − or ind (indeterminate) and is assigned on the basis of the direction of this product. Using a FIE threshold of ≥2.5 as the start of the fertile phase, the FSDs were Day −5 or Day −6, with FSD Day −4 for an outlier set of E2 levels. The maximum FIE value ranged 9.5–27.8 and occurred most often on Day −2. An inflection point with a large change in FIE magnitude and change in sign from + to − always occurred at Day 0 for all sets of day-specific E2 data signaling transition to the luteal phase. Conclusions: The fertility indicator equation, a product of two sequential normalized changes in serum E2 levels with a sign indicating confidence in direction of change, is powerful in identifying the fertile phase and subsequent transition to the postovulatory phase and may serve as a useful algorithm for FAMs of family planning.


2020 ◽  
pp. 30-40
Author(s):  
M. G. Melnik

Purpose. To study the dynamics of blood pressure (BP) indicators under the influence of exogenously administered melatonin (Melatonin-SZ, Severnaya Zvezda, Russia) with various manifestations of desynchronosis of circadian BP rhythms (arterial hypertension – AH, high normal blood pressure) to determine the scheme of their effective compensation. Material and methods. The study included 101 patients with desynchronosis of circadian rhythms of blood pressure – 52 patients with hypertension, constituting the first and second groups, and 49 individuals with high normal blood pressure, representing the third and fourth groups. Patients of the second and fourth groups received conservative therapy, patients of the first and third groups combined it with melatonin. All patients underwent measurements of office blood pressure, home monitoring of blood pressure (ABPM), electrocardiography, 24-hour blood pressure monitoring (ABPM). Results and discussion. In patients of the first and third groups, compared with the traditional treatment groups, by the end of the observation period, a significantly (p < 0.05) decrease in office systolic blood pressure (SBP) / diastolic blood pressure (DBP) was established: in the first group compared with the second – 1.11 / 1.13 times, in the third group compared to the fourth – 1.43 / 1.58 times; significantly more (p < 0.05) pronounced decrease in SBP / DBP during DMAD – by 1.08 / 1.17 and 1.58 / 1.62 times, respectively, Significantly (p < 0.05) more pronounced decrease in average daily, average daily and average nighttime SBP / DBP during ABPM – by 1.13 / 1.20, 1.11 / 1.20, 1.23 / 1.25 and 1.47 / 1.31, 1.42 / 1.19, 1.54 / 1.41 times, respectively; reliably (p < 0.05) more frequent registration of the dipper rhythm type SBP / DBP – 1.6 / 1.4 and 1.6 / 1.4 times, respectively. In addition, the dynamics of patients in the first and third groups showed a significant (p < 0.05) decrease in the mean daily and mean nighttime SBP / DBP variability (SBP in the first group by 27.3 and 41.3 %, respectively; DBP in the first group by 20.1 and 26.3 %, respectively; SBP in the third group by 13.5 and 25.2 %, respectively; DBP in the third group by 12.2 and 28.2 %, respectively). Conclusions. With various manifestations of desynchronosis of circadian rhythms of blood pressure (AH, high normal blood pressure), the prescription of melatonin (Melatonin-SZ, Severnaya Zvezda, Russia) at a dose of 3 mg per day 30–40 minutes before bedtime for a month against the background of non-drug therapy and antihypertensive drugs led to a significantly more effective decrease in blood pressure at its office measurement, DMAD, ABPM with an improvement in the circadian rhythm of blood pressure and normalization of blood pressure variability.


2010 ◽  
Vol 6 (3) ◽  
pp. 87
Author(s):  
Niraj Varma ◽  

The use of implantable electronic cardiac devices is increasing. Post-implantation follow-up is important for monitoring both device function and patient condition; however, clinical practice is inconsistent. For example, implantable cardioverter–defibrillator follow-up schedules vary from every three months to yearly according to facility and physician preference and the availability of resources. Importantly, no surveillance occurs between follow-up visits. By contrast, implantable devices with automatic remote monitoring capability provide a means for performing constant surveillance, with the ability to identify salient problems rapidly. The Lumos-T Reduces Routine Office Device Follow-up Study (TRUST) demonstrated that remote home monitoring reduced clinic burden and allowed early detection of patient and/or system problems, enabling efficient monitoring and an opportunity to enhance patient safety. The results of the trial have significant implications for the management of patients receiving all forms of implantable electronic cardiac device.


Sign in / Sign up

Export Citation Format

Share Document